Page 1
BOX CONTENTS VARIO IP PoE LAMP Either Infra-Red or White-Light USB Memory Stick Containing Full User instructions & Raytec Discovery Tool App Quick Start Instructions Minimum System requirements: - PC running Windows 7 with IE8 and network access. WARNINGS ...
Please Note : To maintain the environmental integrity of the product, as part of the installation, the multicore auxiliary cable must be terminated appropriately regardless of which cores are being used. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 3
POE link. Some Phihong brand PSE equipment requires a 12.5KΩ detection resistance. For 24.9 KΩ, slide switch to the LEFT (as shown). For 12.5 KΩ, slide switch to the RIGHT. Detection Resistance Selection Switch www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 4
The hard reset button on the lamp should be used only as a last resort to restore connection to the lamp. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Select required angle for lamp. Standard angle is 35°. Change angle as required (see page Attach lamp to wall, housing or pole using U-bracket provided or dedicated Raytec bracketry. Connect lamp to PSE and network using waterproof connector provided or separate junction box.
Page 7
If you wish to have lamp operated via its integrated web browser – then ensure that local control box on Settings/Groups page is ticked. This is the default. To operate the lamp via VMS or Raytec software, then deselect the local control box. Standard set up – see factory defaults below for all default settings.
If the lamp is discovered and the “State” indicator is grey, this indicates that there is no communications with the lamp – check IP Address and Subnet Mask are set within the correct range. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Type of Input = Volt Free Active State = Short Circuit/Low External Output Trigger State = Photocell Only Active State = Short Circuit/Low Photocell Sensitivity = 20 lux www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
192.168.2.80 as the default IP address. Raytec’s Discovery Application is the recommended method for changing an IP address. This free application is available on the USB Memory Stick supplied with the product or please contact Raytec to supply the latest version.
Page 11
Discovery Tool now by double clicking on the lamp from the list of discovered lamps. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 12
To change these via the Discovery Application, highlight the lamp you want to change. Then press “Status”. Unit Name and Group Name can both be edited by entering a new value in their fields. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 13
When changes are made to a lamp or a new lamp is added there may be a small delay in making contact or updating the information and so “Discover” may need to be pressed more than once. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 14
Selecting the Parameters button within the Unit Details screen provides a high level of detailed information regarding the performance and operation of the lamp. This is designed to be used during detailed diagnostics of the lamp with Raytec or your supplier. www.rayteccctv.com...
If you are an administrator, you will have to use the Hard Reset button on the lamp – refer to instructions on page 30. This will restore the lamp to factory defaults which includes user names and passwords. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
To turn all lamps on in the same group and control power level – select the Group ON button. All lamps in a group will turn on to the power setting selected. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 17
The current pattern and frequency of the deterrent is displayed and can be changed on SETTINGS/GROUP Page. Power setting of lamp(s) in deterrent mode can also be adjusted by using slider bar. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Inputs. The lamp can be configured to operate from the above inputs independently and the power level, duration and soft start function can be configured. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 19
Group commands. If Group Control is selected from Trigger Control options, then the user can select two modes of operation in response to Group Commands: www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 20
External Input 100% Duration This will dictate the amount of time the lamp turns on (if on command is selected) from receipt of a valid instruction. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 21
Factory Defaults: Photocell External Input Deterrent Pattern & Frequency There are 3 selectable deterrent patterns available if Deter feature selected from Lamp Mode on Trigger: www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 22
Factory Defaults: Volt free Factory Defaults: Short Circuit/Low Advanced settings- External Output The External Output is a volt free open/closed output. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 23
65 lux Factory Defaults: 20 lux There is a high level of hysteresis and an in-built delay incorporated to avoid switching on/off in marginal lighting conditions. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
32 characters – alpha, numeric and symbols allowed User Name 32 characters – alpha, numeric and symbols allowed Passwords WARNING: For changes to take effect, the SAVE button must be pressed www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
VARIO IP lamp. We suggest that these settings should only be changed by experienced users. WARNING: For changes to take effect, the SAVE button must be pressed www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
This is for information only and cannot be altered on this page. Reboot/Restart Lamp It is also possible to reboot/restart the lamp. The lamp will restart using the existing settings of the lamp. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
Page 27
At any stage, it is possible to restore the original factory settings of the lamp. Any settings that have been previously changed will be lost. During the restore factory settings the lamp may come on/flash for a short period. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
If these faults are cleared the LED indicators will remain red until the system is rebooted from the System Information screen. The LEDs will turn Green, but if the faults persist the LEDs will turn Red. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
This page is useful for detailed troubleshooting and displays diagnostics and information about the lamp. It is intended to be used for detailed troubleshooting with Raytec. Note information on this page is not refreshed automatically and requires the page to be reloaded or refreshed by pressing function key F5 or pressing the refresh on your web browser or simply selecting the page again from the navigation bars on the left.
To upload a new version of software/firmware, please contact Raytec to receive a copy of the latest version software. Once received or downloaded onto a computer on the network, select file to upload – then press Install New Software. We would recommend that the software update is undertaken when network traffic is at a minimum.
The lamp can now be discovered using the Discovery Application and can be configured as required following the instructions in this manual. Hard Reset Button www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...
My lamp doesn’t trigger from an external input My lamp is not responding to group messages correctly The Raytec Network Lamp has been designed such that it can be integrated into a 3 party system such as a VMS. Please contact Raytec to discuss your particular requirements.
Page 33
Raytec Systems Inc. 800-300 Terry Fox Drive Ottawa, Ontario K2K 0E3, Canada Tel: + 1 613 270 9990 Toll Free: +1 888 505 8335 ussales@rayteccctv.com www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Raytec Americas Tel: +1 613 270 9990...