GAS CONNECTIONS

LOCAL AUTHORITY REQUIREMENTS
Check Gas Type and specifications plate placed on the bottom face of the unit. All gas fitting work,
service and repairs can only be performed by an authorised person in accordance with the current
edition of AS5601 and local gas regulations. Failure to comply with this condition will render the
warranty invalid. Always unplug the appliance before carrying out any maintenance operations or
repairs. The walls of the units must not be higher than work top and must be capable of resisting
temperatures of 75 above the ambient temperature. Do not install the appliance near flammable
materials (eg. curtains). The final act of any installation or gas type conversion must be the full testing of
this appliance, which includes leak testing, ignition and functionality of the burner.
INSTALLATION
The appliance is supplied ready to operate with the gas indicated on the specifications plate (normally
NG) applied onto the appliance. Please see gas rates summary information on the previous page.
If the appliance must be operated with a gas different than that indicated on the plate, it is necessary to
execute the following operations:
- Gas connection including regulator (NG) or test point nipple adaptor (ULPG) to be changed.
- Replacement of the injector.
- Adjust the primary air inlet.
- New gas label attached stating gas type.
- Adjustment of minimum setting on valve.