Udl2 Equipment Specifications - Cortalk uDL2 Configuration & Operation Manual

Data logger for cp coupons
Table of Contents

Advertisement

A. uDL2 Equipment Specifications
Operating Temperature
Charging Temperature
Storage Temperature
Humidity
Maximum Altitude
Pollution Degree
Size
Weight
Enclosure
Measurement Type
Analog Ranges
(Potential)
(Current-G1 model
(Current-G2/G3 model
AC Rejection on DC Readings
Input Impedance (Potential)
External Analog Channels
Lightning Immunity
Temp. Measurement Accuracy
Potential DC Accuracy
Potential AC Accuracy
Current DC Accuracy
Current AC Accuracy
Accuracy Aging
ADC Resolution
Memory Size
Battery
GPS Receiver
Output File Data Resolution
*
The uDL2 model for a particular unit can be determined by looking at the back label area. G1 models will be labelled
as 'uDL2' or 'uDL2-G1', while G2/G3 models will be labelled explicitly as 'uDL2-G2' or 'uDL2-G3'.
Technical assistance may be obtained from:
Attn: Service Department
Mobiltex Data Ltd.
th
3640-26
Street NE
Calgary, AB T1Y 4T7
Canada
Tel: (403)291-2770
Main Website:
http://www.cortalk.com
Service Website:
http://www.mobiltex.com/service
MOBILTEX® DATA LTD.
Calgary, Alberta
www.corTalk.com
-20 to +60 C (-4 to +140 F)
0 to +40 C (32 to +104 F)
-40 to +70 C (-40 to +158 F)
0 to 100% RH non-condensing
5000 meters above sea level
1
89mm x 40mm x 18mm (3.5" x 1.6" x 0.72")
75 grams (2.7 oz)
UV stable, wide temperature polycarbonate
Category 2 (as per CSA C22.2 – 61010)
+/- 22VDC, 15V true RMS AC, +/-22Vpeak
*
)
Medium: +/-60mADC, 40mA true RMS AC, +/-60mApeak
High: +/-300mADC, 200mA true RMS AC, +/-300mApeak
*
) Low: +/-7mADC, 5mA true RMS AC, +/-7mApeak
Medium: +/-70mADC, 50mA true RMS AC, +/-70mApeak
High: +/-300mADC, 200mA true RMS AC, +/-300mApeak
>65dB @ 50/60Hz
>20Mohm
2 galvanically isolated with shared common
Survives multiple 20KV 10mS surges
+/-4 C (+/-7 F) over -20 to +60 C (-4 to +140 F)
over -20 to +60 C (-4 to +140 F)
+/-0.55% + 5mV
over -20 to +60 C (-4 to +140 F)
+/-1% + 5mV, 20mV floor
over -20 to +60 C (-4 to +140 F)
+/-0.5% + 2uA (low range)
+/-0.5% + 20uA (med range)
+/-0.5% + 750uA (high range)
over -20 to +60 C (-4 to +140 F)
+/-1% + 20uA, 50uA floor (low range)
+/-1% + 25uA, 100uA floor (med range)
+/-1% + 750uA, 750uA floor (high range)
+/-0.13% per year
16 bits
2,000,000 readings
Internal Li-Ion (Not user replaceable)
50-channel u-blox
1uV/1uA for AC and DC readings
0.1 for temperature readings
0.00001 for GPS position
TITLE: uDL2 Configuration and Operation Guide