Cortalk uDL2 Configuration & Operation Manual

Data logger for cp coupons
Table of Contents

Advertisement

Quick Links

uDL2 Data Logger for
CP Coupons
Configuration and Operation Guide
Print Date:
March 26, 2018
MOBILTEX® DATA LTD.
TITLE: uDL2 Configuration and Operation Guide
Calgary, Alberta
DOCUMENT NO.:
SHEET:
REV:
www.corTalk.com
UDL2-MAN-001
1 of 28
1.07

Advertisement

Table of Contents
loading

Summary of Contents for Cortalk uDL2

  • Page 1 Data Logger for CP Coupons Configuration and Operation Guide Print Date: March 26, 2018 MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com UDL2-MAN-001 1 of 28 1.07...
  • Page 2 Added information on overcurrent detector retries for v1.09 firmware. Added generic connection diagrams for coupon and dual potential mode. 1.07 Mar 26, 2018 Added uGL2-G3 to specifications table. Tony da Costa MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com UDL2-MAN-001 2 of 28 1.07...
  • Page 3: Table Of Contents

    4.2.1 Configuration Application Installation ....................10 4.2.2 Driver Installation ........................... 12 4.2.3 Adobe Acrobat Reader XI ........................12 uDL2 Configuration and Extraction ....................... 13 4.3.1 uDL2 Communications and Status ......................13 4.3.1.1 Read Config From uDL2 ........................13 4.3.1.2 Write Config To uDL2 ........................13 4.3.1.3...
  • Page 4 Figure 4 uDL2 USB Cable ............................... 7 Figure 5 uDL Black Fabric Case ............................7 Figure 6 uDL2 Analog Cable and Extension Clip Adapters ..................... 8 Figure 7 Large Alligator Clips ............................8 Figure 8 Programming Application and Driver USB Flash Drive ..................8 Figure 9 CC Technologies Coupon Test Station Direct Interface Cable ................
  • Page 5: Introduction

    1 Introduction The uDL2 is a high accuracy, two channel data logger designed for use with CP coupons. An integral current detector with interruption relay allow direct measurement of coupon AC current density and coupon DC current. A reference cell input provides DC potential, AC voltage and Instant-disconnect DC potential measurements.
  • Page 6: General Safety Information

    DANGER. Danger indicates an injury hazard immediately accessible as you read the marking. WARNING. Warning indicates an injury hazard not immediately accessible as you read the marking. CAUTION. Caution indicates a hazard to property including the product. MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com...
  • Page 7: Udl2 Kit Contents

    3 uDL2 Kit Contents The Mobiltex part number for the uDL2 kit is A20A03UDL20 (non-USA) or A20A03UDL21 (USA). The following items are included in each kit:  uDL2 Data Logger for CP Coupons Unit (A15000UDL20 non-USA, A15000UDL21 USA) Figure 3 uDL2 Front View ...
  • Page 8: Figure 6 Udl2 Analog Cable And Extension Clip Adapters

    Figure 8 Programming Application and Driver USB Flash Drive To use a PC to communicate with the uDL2, you will require the media (CD or USB flash drive) that shipped with the uDL2. The media contains drivers and the uDL2 configuration application. If you do not have the media, the contents can be downloaded from the Mobiltex web site at the following URL.
  • Page 9: Figure 9 Cc Technologies Coupon Test Station Direct Interface Cable

    Test Station Spacer Rings (Provide More Height Inside Standard Test Station) H23510RMU01 (Black) H23530RMU01 (Orange) H23540RMU01 (Yellow) H23550RMU01 (Green) Figure 12 Test Station Spacer Rings MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com UDL2-MAN-001 9 of 28 1.07...
  • Page 10: Configuration

    Programming Application and Driver Media (CD or USB flash drive) To use a PC to communicate with the uDL2, you will require the media (CD or USB flash drive) that shipped with the uDL2. The media contains drivers and the uDL2 configuration application. If you do not have the media, the contents can be downloaded from the Mobiltex web site at the following URL.
  • Page 11: Figure 14 Udl2 Configuration Application Installation Dialog

    Figure 15. Click “Close” to complete the installation. Figure 15 uDL2 Configuration Application Installation Complete A shortcut to the configuration application and the uDL2 manual are created in the Windows start menu under the “uDL2 Configuration Application” folder.
  • Page 12: Driver Installation

    Follow the installation instructions presented by the driver installer application. Figure 16 Driver Installation Screen Once the driver installer completes, you may then plug in the uDL2 through the USB cable into an available USB port on the PC.
  • Page 13: Udl2 Configuration And Extraction

    4.3.1.1 Read Config From uDL2 The first step in configuring a device is to read in the current settings from the unit. Click on “Read Config From uDL2”. The “Link Status” field will briefly show “Busy” as the current configuration parameters are read from the uDL2. After the link status returns to “Idle”, you will see the configuration settings currently in the uDL2.
  • Page 14: Firmware

    4.3.1.8 Set uDL2 Clock The “Set uDL2 Clock” is used to set the clock of the uDL2 from the PC clock. Note that in GPS equipped units, the uDL2 clock will automatically be set from the GPS receiver as soon as a valid GPS time fix is detected.
  • Page 15: Reboot Udl2

    The “Disconnect Duration” value is how long the relay is left open for each disconnect event. After each relay transition, the uDL2 will wait before taking the next DC potential measurement; this wait time is determined by one of the two “Sampling Delay” parameters.
  • Page 16: Coupon Potential Sampling (Ch1) Or Potential Sampling (Ch1)

    4.3.2.3 Coupon Current Sampling (CH2) or Potential Sampling (CH2) The second channel on the uDL2 may be used for measuring coupon current, or it may be used to measure a second potential point. The measurement type is selected by clicking on the appropriate radio button under the mode heading (see Figure 20).
  • Page 17: Ch2 Potential Mode

    The time may be displayed in UTC or local time. Click on the corresponding radio button to select the display time type. For local time, the time zone of the configuration PC is used to select time zone offset for the uDL2 display.
  • Page 18: Data Memory Group

    The “Extract To Master Data File” button allows extraction of the measurement data from the uDL2 into a CSV file. Prior to clicking this button, ensure that the desired time format is selected. Data may be extracted in UTC (GMT) time, or in local time.
  • Page 19: Figure 24 Sample Master Data File

    Figure 24 Sample Master Data File MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com UDL2-MAN-001 19 of 28 1.07...
  • Page 20: Figure 25 Master Data File Split Utility

    The “Master Data File Split Utility” button invokes a utility function that is used to further process the data from the uDL2 for use in other analysis applications. The function allows a master data file to be split into separate output files for DC, AC, temperature, and DC wave readings.
  • Page 21: Figure 26 Data Preview Charts Selection

    Data charts can be printed and saved. After the data has been extracted from the uDL2, the data memory on the device may be cleared by clicking the “Clear Memory” button. Note that clearing memory may take up to 60s to complete.
  • Page 22: Operation

    The waterproof connector that mates to the uDL2 has an automatic physical locking function. The white arrow on the cable should align with the black arrow on the top graphic overlay of the uDL2. When the cable is inserted, it will “click”...
  • Page 23: Figure 29 Dual Potential Analog Cable Attachment To A Test Station

    (Dual Potential Mode) Potential 1 Potential 2 Black Blue Figure 29 Dual Potential Analog Cable Attachment to a Test Station MOBILTEX® DATA LTD. TITLE: uDL2 Configuration and Operation Guide Calgary, Alberta DOCUMENT NO.: SHEET: REV: www.corTalk.com UDL2-MAN-001 23 of 28...
  • Page 24: Figure 30 Udl2 Back View

    The GPS antenna is located on the end opposite the uDL2 connector.
  • Page 25: Figure 32 Udl2 Front Face

    When the memory of the device is full the uDL2 will display “FUL” on its LCD, mark the measurement memory with a full indication and stop taking measurements. The 2,000,000 measurement memory will provide about 22.8 days of measurements at a 1 second sample rate for a single channel.
  • Page 26: Firmware Updates

    Figure 33 uDL2 Firmware Update Application Dialog To start the firmware update process, first ensure that the uDL2 is connected to a USB port on the computer. Next, click on the ‘Program Firmware’ button. The application will indicate progress as the firmware is downloaded to the uDL2 (see Figure 34).
  • Page 27: Udl Registration

    Figure 34 uDL2 Firmware Update Application Progress The latest uDL2 software package may be downloaded from the Mobiltex web site at the following URL: http://www.mobiltex.com/cathodic/udl2 uDL Registration Visit www.mobiltex.com/service/registration.html register your uDL to receive notification of free firmware updates. Information provided will be used for the sole purpose of sending notification of firmware updates, and will never be shared or sold.
  • Page 28: Udl2 Equipment Specifications

    0.00001 for GPS position The uDL2 model for a particular unit can be determined by looking at the back label area. G1 models will be labelled as ‘uDL2’ or ‘uDL2-G1’, while G2/G3 models will be labelled explicitly as ‘uDL2-G2’ or ‘uDL2-G3’.

Table of Contents