The JA-159P wireless outdoor PIR detector
The following table represents the values included in the figure:
Maximum range of the lower detecting part
Position
Average value
1
12 m
2
8.5 m
3
6 m
4
3.5 m
5
2.5 m
Warning: The maximum detection length of the lower detection plane
may vary as above due to environmental thermal conditions. This must
be taken into consideration during detection range adjustment.
Fig. 5.
The detection area angle is 90°. The direction can be adjusted
from position A – G by rotating the detector´s plastic part. Each step
is marked. The detector lens covers the whole angle of 180°
- therefore it does not require any adjustment.
You can restrict the detection angle by adhesive masking strips
supplied with the package. This way you can eliminate problematic
parts of the detection area. The strips are to be stuck on the relevant
lens segment from the inner side.
The PIR detection sensitivity can be configured by a 3-pole switch
located under the upper sensor. The letters correspond to sensitivity
levels as follows:
L
low – low sensitivity applicable to bad conditions
M middle – medium sensitivity
H
high – high sensitivity
Other parameters can be configured using a DIP switch
(factory settings highlighted by bold letters):
NORM
120s
N.C.
LED OFF
Antimasking OFF
The LED (DIP switch no. 4) serves for PIR detector testing
– checking the coverage. The detector always sends information
to the control panel. For normal detector operation we recommend
the LED to be turned off in order to save the battery.
The power save mode can be set up by DIP switch no. 2, select
5 s / 120 s. It determines the time when detector is able to detect
movement again and send a new activation signal.
When Antimasking is ON (DIP switch no. 5), the detector monitors
any masking of its view. When the power is turned on the detector
starts
with
a
1
minute
mode
the environment and then starts a 10 minute test mode (antimasking
is triggered when obstruction of the detector takes at least 20 sec).
In normal operation mode the detector has to be obstructed at least
for 3 minutes. Evaluation of the obstructed detector signal depends
on system status.
The JA-159P wireless outdoor PIR detector
Fig. 4.
see following limits:
10 to 17 m
7 to 12 m
5 to 8.5 m
3 to 6 m
2 to 3.5 m
Table 1.
TEST
5s
N.O.
LED ON
Antimasking ON
when
the
detector
When the system or a section, where the detector has been
assigned, is unset, a fault is triggered. When the system is set it
will trigger fault + instant zone alarm. Activation of the detector
obstruction signal (masking) is displayed with a yellow indication LED
(which flashes briefly 3x every second).
DIP switch no. 1 is set to TEST mode as a factory default.
We recommend switching DIP switches no. 2 and no. 4 to the ON
position for testing purposes. Close the detector.
Test the detection range of the protected area and immunity
out of the protected area. Bear in mind the potential change
of
detecting
Each movement is indicated by the red indication LED and it sends
the information to the control panel (can be checked by F-Link
software in the Diagnostics tab).
When the testing procedure is finished, move the DIP switch no. 1
to the NORM position. Also, we recommend turning off the LED
indication and setting the power save mode to 120 s to prolong
the battery life.
Problem
The detector
gives false
intrusion
alarms
Occasionally
no reaction
to
movement
Detector
ignores any
movements
Technical specifications
Power:
Current consumption (nominal/maximal)
Average battery lifetime
Communication band
RF range – communication range
Optex detector parameter:
Detection characteristics
Recommended installation height
Object motion speed
Battery saving timer
Operational environment according to EN 50131-1
Security grade
Operating temperature range
Detector cover conformance
Max. relative humidity of the environment
Dimensns
Weight
Complies with
Can be operated according to
scans
2 / 2
Testing (coverage test)
distance
is
influenced
by
Troubleshooting
Cause of problem
Solution
Lower detection area is
Set up the detection area
unnecessarily long.
properly.
The detector is exposed
Remove the reflector,
to direct/reflected light
mask the area exposed to
(sun light, car lights etc.).
the reflection of light or
change the detector
position.
There is a moving object
Remove the moving
in the area (laundry on
object or change the
the clothes-line, plants
detector position. Or put
etc.).
the stickers on part of the
lens to avoid detection in
a problematical place.
Lower detection area is
Set the detection area
unnecessarily short
properly
Sensitivity is set to low
Change sensitivity to
(L).
medium (M) or high (H).
The detector is in battery-
While testing operation,
save mode
set the battery-save timer
to 5 seconds.
Low battery
Replace the battery
LED indicator does not
Indication is turned off,
indicate movement
turn DIP switch no. 4 ON
LED indicator indicates
The control panel is out of
movement but the system
range, check the battery,
doesn't react
try to reposition detector
or control panel
2x Lithium battery type CR123A (3.0 V/1.4 Ah)
Please note: Batteries are not included
2 x CR123A, approx. 3 years
ETSI EN 300 220, EN 50130-4,
JABLOTRON ALARMS a.s. hereby declares that the JA-159P
composed of Optex detector VXI-RAM-NB and radio module
JA-150TX-VXI is in a compliance with the relevant Union
harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU,
2014/30/EU,
2011/65/EU.
The
assessment can be found at www.jablotron.com - Technical Section
Downloads.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly
to the producer after use.
the
environment.
35.5 μA/55 mA
868.1 MHz
up to 300 m (open area)
12 m/90 °; 16 segments
0.8 – 1.2 m
-1
0.3 – 1.5 ms
adjustable 5 s or 120 s
IV
according to Optex
-20 °C to +60 °C
IP55
95 %
186 x 71.3 x 105.5 mm
500 g
EN 55022, EN 60950-1
ERC REC 70-03
original
of
the
conformity
MMY51809