Table of Contents

Advertisement

Available languages

Available languages

OWNER'S MANUAL

AIR CONDITIONER

Please read this manual carefully before operating
your set and retain it for future reference.
TYPE:WALL MOUNTED
MODELS
SP182CN
SP182CN
N50
SP242CN
SP242HN
US0
P/NO:MFL67445124
SP182HN
US0
N50
SP242HN
N50
US0
SP182HN
SP242CN
US0
N50
www.lg.com

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for LG SP182CN N50

  • Page 1: Air Conditioner

    OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE:WALL MOUNTED MODELS SP182CN SP182CN SP182HN SP182HN SP242CN SP242CN SP242HN SP242HN www.lg.com P/NO:MFL67445124...
  • Page 2: Table Of Contents

    Room Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS A. Safety Precautions ......3 B. Electrical Safety........6 Write the model and serial numbers here: Temporary Use of an Adapter ....6 Model # Temporary Use of an Extension Cord ...6 Serial # Symbols used in this Manual....6 You can find them on a label on the side of each unit.
  • Page 3 Plug in the power plug properly. Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not operate or stop the unit by inserting or pulling out the power plug. It will cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord.
  • Page 4 Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Improper or loose connections can cause heat generation or fire. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags.
  • Page 5 Keep level even when installing the product. To avoid vibration or noise. Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods. It may cause a problem for your neighbors and hence dispute. Always check for gas (refrigerant) leakage after installation or repair of product.
  • Page 6: Electrical Safety

    Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
  • Page 7: Product Introduction

    Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Standard Split Type Display panel LED indicators Air Inlet Front Panel ON/OFF Button Air Filter Signal Receptor Art Cool Type Wide...
  • Page 8: Operation Indication Lamps

    Product Introduction Operation Indication Lamps : Lights up during the system operation, error code and auto restart setting. On/Off Sleep mode : Lights up during sleep mode auto operation.(non-Inverter Model) Plasma : The function illustrates its dynamic mode by using a multiple lighting system. : Lights up during timer operation.(non-Inverter Model) Timer Lights up during timer operation or sleep mode auto operation (Inverter Model only)
  • Page 9: Operating Instructions

    Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
  • Page 10: Wireless Remote Controller Cooling Only Model

    Operating Instructions Wireless Remote Controller (Cooling Only Model) Control Display Description panel screen Fan button : Air come out from the indoor unit below to the room without air temperature change. Display screen Sleep mode auto button*: Sets the sleep mode auto operation. Temperature adjustment buttons: Adjusts the room temperature when cooling and heating.
  • Page 11: Wireless Remote Controller Heat Pump Model

    Operating Instructions Wireless Remote Controller (Heat Pump Model) Control Display Description panel screen Fan button : Air come out from the indoor unit below to the room without air temperature change. Display screen Sleep mode auto button*: Sets the sleep mode auto operation. Temperature adjustment buttons: Adjusts the room temperature when cooling and heating.
  • Page 12: Operation Mode

    Operating Instructions Operation Mode Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep. Press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Auto Heating Cooling...
  • Page 13: Auto Operation

    Operating Instructions Auto Operation <For Cooling Model> The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect. You cannot switch the indoor fan speed.
  • Page 14: Air Circulation Operation

    Operating Instructions Air Circulation Operation This operation circulates the air without cooling. It can be activated by pressing the OPERATION MODE SELECTION BUTTON. Once the air circulation is activated you can select the fan speed by pressing the INDOOR FAN SPEED SELECTION BUTTON. Auto Clean Operation During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed.
  • Page 15: Energy-Saving Cooling Model

    Operating Instructions Energy-Saving Cooling Mode Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting desired temperature automatically. 1. Press the ON/OFF BUTTON to start the unit. 2.
  • Page 16: Timer Setting

    Operating Instructions Timer Setting Button on the Description Indication on the LCD Display Remote Controller Press the Timer button once to set on the Reserved 'On' or 'Off'. Press the Time Setting buttons until the desired time is set. Press the SET/CLEAR BUTTON To cancel the timer setting •...
  • Page 17: Horizontal Vane Control

    Operating Instructions Horizontal Vane Control 1. To adjust the direction of the air flow horizontally, press i repeatedly and select the desired direction. - Select H to adjust the direction of the air flow automatically. 2. To adjust the direction of the air flow vertically, press j repeatedly and select the desired direction. - Select I to adjust the direction of the air flow automatically.
  • Page 18: Maintenance And Service

    The location of the filters may differ, depending on the model. • • If you need more filters,please contract the LG service center (refer to the warranty card,) Installation of new multi protection filter • Pull out the multi protection filter from the separately packed plastic bag.
  • Page 19 Maintenance and Service Removal of Filters Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock. 1. Deluxe (Type 1): Open the upside of the panel and lift it up as shown. The hooks of the panel will come off. Remove the air filters.
  • Page 20: Outdoor Unit

    Maintenance and Service Type 2: Pull the front panel from both sides as shown. Then pull the filter tab slightly forward to remove the filter. After removing the air filter remove the plasma and triple deodorizer filter by slightly pulling forward. Deodorizer filter Plasma filter...
  • Page 21: Troubleshooting Tips! Save Time And Money

    Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes What To Do The air conditioner is • Make sure the air conditioner plug is unplugged. pushed completely into the outlet. The fuse is blown/circuit •...
  • Page 22: Spec Sheet

    Maintenance and Service SPEC SHEET : COOLING HEATING MODEL VOLTAGE INPUT CURRENT INPUT CURRENT SP182CN N50 220 V 1 740 8,2A SP182CN US0 220 V 1 740 8,2A SP182HN N50 1 950W 220 V 9,0A 8,6A 1 740 SP182HN US0...
  • Page 23 SP182CN SP182CN SP182HN SP182HN SP242CN SP242CN SP242HN SP242HN www.lg.com...
  • Page 24 Manual del propietario del aire acondicionado CONTENIDO PARA SUS ARCHIVOS A. Precauciones de seguridad ......3 B. Seguridad eléctrica........6 Escriba el número de modelo y el de serie aquí: Uso temporal de un adaptador......6 Nº de modelo Uso temporal de un alargador de alimentación ..........6 Nº...
  • Page 26 Para realizar una limpieza interna, contacte a un Centro de Servicio Autorizado o a un distribuidor. No utilice detergentes duros que pueden causar corrosión o daño a la unidad. El detergente duro también puede ocasionar fallas al producto, fuego o descarga eléctrica.
  • Page 27 ADVERTENCIA: Antes de acceder a las terminales, todos los circuitos de alimentación deben desconectarse. ADVERTENCIA: Este aparato no es accesible al público en general. ADVERTENCIA: El aparato debe instalarse de acuerdo a las regulaciones nacionales para instalaciones eléctricas.
  • Page 28: Seguridad Eléctrica

    Seguridad eléctrica Seguridad eléctrica • Este pequeño electrodoméstico debe estar correctamente puesto a tierra. Para reducir al mínimo el riesgo de descargas eléctricas, siempre deberá enchufar la unidad en una toma con puesta a tierra. • No corte ni quite la clavija de puesta a tierra del enchufe de alimentación. •...
  • Page 29: Presentación Del Producto

    Presentación del producto Presentación del producto A continuación encontrará una breve presentación de las unidades de interior y exterior. Por favor, consulte la información específica relativa al tipo de su unidad interior. Unidades interiores Tipo Split estándar (unidad separada) Indicadores LED en el panel de visualización Entrada de aire Rejilla frontal Botón ON/OFF (encendido/apagado)
  • Page 30: Indicadores Luminosos De Funcionamiento

    Presentación del producto Indicadores luminosos de funcionamiento Encendido/ : Se encenderá durante el funcionamiento del sistema, en caso de código de error apagado y ajuste de reinicio automático. Modo reposo : Se enciende durante el funcionamiento automático del modo reposo.(Modelo no inversor) Plasma : La función ilustra su modo dinámico utilizando un sistema de iluminación múltiple.
  • Page 31: Instrucciones De Funcionamiento

    Instrucciones de funcionamiento Instrucciones de funcionamiento Inserción de pilas 1. Retire la cubierta de la batería tirando en la dirección de las flechas. 2. Inserte las pilas nuevas asegurándose de que los polos (+) y (-) se colocan en la posición correcta.
  • Page 32: Mando A Distancia Inalámbrico

    Instrucciones de funcionamiento Mando a distancia inalámbrico ( Modelo sólo enfriamiento) Panel de Pantalla de Descripción control visualización Botón del ventilador:El aire sale de la unidad interior hacia abajo sin cambio de temperatura ambiente. Botón modo auto suspensión*: Pantalla de Configura el modo auto suspensión.
  • Page 33: Mando A Distancia Inalámbrico ( Sólo Modelo Bomba De Calor )

    Instrucciones de funcionamiento Mando a distancia inalámbrico (Sólo modelo bomba de calor) ) Panel de Pantalla de Descripción control visualización Botón del ventilador:El aire sale de la unidad interior hacia abajo sin cambio de temperatura ambiente. Botón modo auto suspensión*: Pantalla de Configura el modo auto suspensión.
  • Page 34: Modo Funcionamiento

    Instrucciones de funcionamiento Modo funcionamiento Pulse el BOTÓN ON/OFF (ENCENDIDO/APAGADO) para encender la unidad. La unidad responderá con un pitido. Pulse el botón de modo de operación. Cada vez que pulse el botón, el modo de operación cambiará en la dirección de la flecha.
  • Page 35: Funcionamiento Automático

    Instrucciones de funcionamiento Funcionamiento automático <Para modelos de refrigeración> La temperatura y la velocidad del ventilador se configura automáticamente con los controles electrónicos basándose en la temperatura real de la sala. Si tiene calor o frío, pulse los botones de CONFIGURACIÓN DE TEMPERATURA para aumentar el efecto de calor o frío.
  • Page 36: Operación Circulación De Aire

    Instrucciones de funcionamiento Operación circulación de aire Esta operación hacer circular el aire sin enfriar ni calentar. Puede activarse pulsando el BOTÓN DE SELECCIÓN DE MODO DE OPERACIÓN. Una vez activada la circulaciónde aire, puede seleccionar la velocidad del ventilador pulsando el BOTÓN DE SELECCIÓN DE VELOCIDAD DE VENTILADOR DE INTERIOR.
  • Page 37: Modo De Refrigeración Con Ahorro De Energía

    Instrucciones de funcionamiento Modo de refrigeración con ahorro de energía El modo de refrigeración con ahorro de energía podemos ahorrar energía en la operación de refrigeración, ya que puede funcionar de forma eficiente configurando el tiempo de adaptación del cuerpo al cambio de tiempo y temperatura y ajustando automáticamente la temperatura que desee.
  • Page 38: Operación Ajuste Del Temporizador

    Instrucciones de funcionamiento Operación ajuste del temporizador Botón del Descripción Indicadores de la pantalla LCD control remoto Pulse una vez el botón del temporizador para configurar “Encendido” o “Apagado”. Pulse los botones de configuración de hora hasta que seleccione la hora que desee. Pulse el BOTÓN SET/CLEAR (CONFIGURAR/BORRAR).
  • Page 39: Control De Dirección Vertical/Horizontal Del Flujo De Aire (Opcional)

    Instrucciones de funcionamiento Control de dirección vertical/horizontal del flujo de aire (Opcional) 1. Para ajustar la dirección del aire horizontalmente, pulse i repetidamente y seleccione la dirección deseada. - Seleccione H para ajustar automáticamente la dirección del flujo de aire. 2.
  • Page 40: Mantenimiento Y Servicio

    La ubicación del filtro puede ser diferente dependiendo del modelo. • • Si necesita más filtros, por favor, contacte con el centro de servicio de LG. (refiérase a la carta de garantía,) Instalación de un nuevo filtro multi protección •...
  • Page 41 Mantenimiento y servicio Desmontaje de filtros No toque el filtro plasma en los 10 segundos siguientes a la apertura de la rejilla de entrada, podría causar descargas eléctricas. 1. Tipo Deluxe (Tipo 1): Abra la parte superior del panel e inclínelo como se muestra. Los ganchos del panel se desprenderán. Desmonte los filtros de aire.
  • Page 42: Unidad Exterior

    Mantenimiento y servicio Tipo 2: Extraiga el panel delantero de ambos lados, como se muestra. A continuación, tire levemente hacia delante de la lengüeta del filtro a fin de extraerlo. Una vez extraído el filtro de aire, retire el de plasma y el triple desodorante tirando con cuidado hacia delante. Filtro! desodorante Filtro de plasma...
  • Page 43: Ahorre Tiempo Y Dinero

    Mantenimiento y servicio Consejos de solución de averías ¡Ahorre tiempo y dinero! El aire acondicionado puede funcionar de forma poco normal cuando: Problema Causas probables Qué hacer El aire acondicionado está • Asegúrese que el aire acondicionado esté desenchufado. enchufado completamente en la salida. El fusible está...
  • Page 44: Especificaciones

    Mantenimiento y servicio ESPECIFICACIONES: REFRIGERACION CALEFACCION MODEL VOLTAGE CONSUMO CORR ENTE CONSUMO CORRIENTE SP182CN N50 220 V 1 740 8,2A SP182CN US0 220 V 1 740 8,2A SP182HN N50 220 V 1 950W 9,0A 8,6A 1 740 SP182HN US0 1 740...
  • Page 45 LG ELECTRONICS MEXICO,S.A. DE C.V. Sor Juana Inés de la Cruz No. 555 Col. San Lorenzo Industrial Tlalnepantla de Baz,Estado de México C.P. 54033 fono:(55)5321-1919 é Sin Costo:01800-3471919 Pagina Web:http://www.lg.com.mx/...

Table of Contents