Advertisement

Quick Links

Models: SP3 Series
Type: Art Cool
IMPORTANT
• Please read this installation manual completely before
installing the product.
• Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
• Please retain this installation manual for future reference
after reading it thoroughly.
LG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for LG SP3 Series

  • Page 1 Models: SP3 Series Type: Art Cool IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference...
  • Page 2: Table Of Contents

    Art Cool Type Indoor Unit Installation Manual TABLE OF CONTENTS Required Parts Required Tools Installation Requirements Installation Parts ....3 Safety Precautions ....4 Installation Installation guide map Level gauge Four type "A" screws & plastic Screw driver anchors Electric drill Selection the best location ..7 Connecting cable Hole core drill Horizontal meter...
  • Page 3: Installation Parts

    Installation Parts Installation Parts Air Intake Air Outlet Securing screws Name Installation guide map (Other) Quantity 1 EA 2 EA • Owner's manual Shape • Installation manual M4 x 12L Installation Manual 3...
  • Page 4: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Be sure to read before installing the air conditioner. Be sure to observe the cautions specified here as they include important items related to safety. Incorrect operation due to ignoring instruction will cause harm or damage.
  • Page 5: Operation

    Safety Precautions Do not modify or extend the Do not let the air conditioner Be cautious when unpacking power cable. run for a long time when the and installing the product. humidity is very high and a door or a window is left open. •...
  • Page 6 Safety Precautions Installation Always check for gas (refriger- Install the drain hose to ensure Keep level even when installing ant) leakage after installation or that water is drained away prop- the product. repair of product. erly. • Low refrigerant levels may cause •...
  • Page 7: Installation

    Installation Installation Read completely, then follow step by step. Selection of the best location • Do not have any heat or steam near the unit. • Select a place where there are no obstacles in front of the unit. • Make sure that condensation drainage can be conveniently routed away. Do not install near a doorway.
  • Page 8: Preparing Work For Installation

    Installation Preparing Work for Installation Open panel front 1. Push the front panel backward and lift it up to remove the two screws. 2. As soon as you lift the both lower parts of panel front, you can hear the sound from panel front. At this moment panel front is separated 3.
  • Page 9: Fixing Indoor Unit

    Installation Fixing Indoor Unit 1. Attach an Installation guide map on the 6. Look at suited horizon by horizontal desired surface. meter on the horizontal setting line, and fix lightly the map by adhesive tape. INSTALLATION GUIDE MAP Horizontality T I O 2.
  • Page 10: Flaring Work

    Installation Flaring Work Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following proce- dure. Cutting the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally.
  • Page 11: Connecting The Piping

    Installation Check Smooth all round 1. Compare the flared work with the figure by. Inside is shiny without scratches 2. If a flared section is defective, cut it off and do flar- = Improper flaring = ing work again. Inclined Surface Cracked Uneven damaged...
  • Page 12: Wrap The Insulation Material Around The Connecting Portion

    Installation Connecting the piping with the indoor unit and drain hose with drain pipe 1. Align the center of the pipings and sufficiently tight- en the flare nut by hand. Indoor unit tubing Flare nut Pipings 2. Tighten the flare nut with a wrench. Outside diameter Torque Spanner (fixed)
  • Page 13: Drain Piping

    Installation CAUTION: Installation Information For right piping. Follow the instruction below. Good case • Press on the upper side of clamp and unfold the tubing to downward slowly. Bad case • Following bending type from left to right may cause damage to the turbing. Drain Piping 1) To check the drainage.
  • Page 14: Panel Front Assembly

    Installation Panel Front Assembly 1. First, Check the side cover assembly exactly, and fix the power cord in the bottom groove of cover side left. 2. Assemble connecting lead wire with controller, fix the upper part of panel front, and match the lower part of panel front.
  • Page 15: Wiring Connection

    Installation Wiring Connection • Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in- dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
  • Page 16: Installation Of Remote Controller

    Installation Installation of Remote Controller HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES 1. Remove the battery cover from the remote controller. • Do not use rechargeable batteries, • Slide the cover according to the arrow direction. such batteries differ from standard dry cells in shape, dimensions, and per- 2.