Pump Requirements; Bruteboiler Flow And Head Requirements; Brutewater Heater Flow And Head Requirements - Bradford White Brute Installation And Operating Instructions Manual

Table of Contents

Advertisement

Brute
HIGH EFFICIENCY COMMERCIAL BOILERS AND VOLUME WATER HEATERS
Section 5 -

PUMP REQUIREMENTS

5.1 Brute Boiler Flow and Head
Requirements - BNTH
TEMPERATURE RISE IN °F
20°F
25°F
FLOW H/L
FLOW H/L
SIZE
GPM
FT
GPM
FT
150 14.3 28.5
11.4 19
20 24.1
16 16.7 13.4 11.6 11.3
199/210
285
27 25.5
22 17.5
399
39
28
31
20
500
48
24
38
16
600
58
44
46
31
750
72
37
58
23
850
81
33
65
22
TEMPERATURE RISE IN °C
11°C
14°C
FLOW H/L
FLOW H/L
SIZE
lpm
m
lpm
m
150
54
8.7
43 5.8
76 7.3
61 5.1
199/210
285 102 7.8
83 5.3
399 148 8.5
117 6.1
500 182 7.3
144 4.9
600 220 13.4
174 9.4
750 273 11.3
220 7.0
850 307 10.1
246 6.7
Table 12. Boiler Water Flow Data
5.2 Brute Water Heater Flow and Head
Requirements - BNTV
Flow
H/L
Size
gpm
feet Rise °F
150
19
49
199
25
28
285
36
33
50
35
399
63
28
500
60
24
600**
750**
68
35
850**
68
26
* Maximum water hardness of 10 grains per gallon allowed.
** See SECTION 6B.7 for pump information.
Table 13. Water Heater Flow Data
30°F
35°F
FLOW H/L
FLOW H/L
FLOW H/L
GPM
FT
GPM
FT
GPM
9.5 13.6
8.1 11.2
7.1 8.8
9
9.9 6.9
18
14
15 10.5
13
25 14.5
22
11
19
32
12
27
9
24
38
22
33
18
29
48
17
41
13
36
54
15
46
10
41
17°C
19°C
FLOW H/L
FLOW H/L
FLOW H/L
lpm
m
lpm
m
lpm
36
4.1
31
3.4
27
51
3.5
43
2.7
37
68
4.3
57
3.2
49
95
4.4
83
3.4
72
121 3.7
102 2.7
91
144 6.7
125 5.5
110 4.6
182 5.2
155 4.0
136 3.0
204 4.6
174 3.0
155 2.4
NORMAL WATER*
Temp
Flow
H/L
lpm
m
15
72
14.9
15
95
8.5
15
98
10.1
15
189
10.7
15
239
8.5
19
227
7.3
21
257
10.7
24
257
7.9
40°F
FT
8
9
8
15
10
8
22°C
m
2.7
2.1
2.4
2.7
2.4
Temp
Rise °C
8
8
8
8
8
11
12
13
Page 25

Advertisement

Table of Contents
loading

Table of Contents