Volume; Key Management - LG LX76 Series Installation Manual

Hide thumbs Also See for LX76 Series:
Table of Contents

Advertisement

16
INSTALLATION MENU

Volume

- Decide to apply volume policy of 'Start Volume' , 'Maximum Volume' and 'Minimum Volume' as Yes(Work) or No(Do Not
Work).
- (0 ≤ Min ≤ Start ≤ Max ≤ 100)
Start Volume
y This entry sets the start volume level when is power on.
- The level is specified as a number between minimum volume to maximum value. (Min ≤ Start ≤ Max)
- The default setting is 'Off' (disabled).
- When enabled, if the value is lower then the minimum specified in the minimum volume entry, the minimum volume
entry must be used.
- When enabled, if the value is larger then the maximum specified in the maximum volume entry, the maximum volume
value must be used.
- Access to a volume in 'On Timer' must be fixed to start volume when 'Hotel Mode Operation' (Yes) and 'Start Volume' (Off, 0
~ 100) were set simultaneously.
Maximum Volume
y This entry sets the maximum volume level the set. The level is specified as a number between 'Minimum Volume' to 100. (Min ≤
Max ≤ 100).
- If the command volume up to higher than maximum volume' is received, that should be ignored.
- The default value is 100.
Minimum Volume
y This entry sets the minimum volume level the set will produce.
- The level is specified as a number between 0 to 'Maximum Volume' . (0 ≤ Min ≤ Max)
- If the command volume down to lower than minimum volume is received, that should be ignored.
- The default value is 0.

Key Management

- Manage key usability of Local(Front) Key and Remote Control. When selected to 'On' , following 'IR Operation' and 'Local Key
Operation' will be worked by below.
IR Operation
y Decide whether work the LG remote control or not.
- When 'IR Operation' is set to 'Normal' , all remote keys are available.
- 'Use PWR Only' makes block all remote keys except power key.
- When 'IR Operation' is set to 'Block All' , all normal remote keys don't work.
Local Key Operation
y Decide to operate 'Local/Front Key' working behavior by setting 'Local Key Operation' as 'Normal' , 'Use PWR Only' and 'Block All' .
- When 'Local Key Operation' is set to 'Normal' , all local keys are available.
- 'Use PWR Only' makes block all local keys except power key.
- When 'Local Key Operation' is set to 'Block All' , all local keys don't work.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lw73 series

Table of Contents