18 – 24.000 btu/h 3d dc inverter split wall-mounted type (41 pages)
Summary of Contents for Klimaire KSIX024-H220
Page 1
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT TYPE ROOM AIR CONDITIONER USER'S & INSTALLATION MANUAL SERIES Read This Manual Keep this manual where the operator can easily find them.Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
CONTENTS Safety Precautions WEEE Warning Name Of Each Part Operation Notices Care and Maintenance Troubleshooting Installation Guide Selection of the installing position Installation of the indoor unit Installation of the outdoor unit Pipe connection Electrical connection Test running Packing list...
Safety Precautions Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications: WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only.
Page 4
6.Don't pull the power cord when pull out the power plug. The damage of pulling power cord will cause serious electric shock. 7.The power plug must be inserted tightly. Otherwise, it can cause electric shock or overheating, even fire. 8.Don't share the socket with other electric appliance, and use the broken or unstandord cord.
Page 5
CAUTION 1.Don't install the indoor unit under sunshine directly. 2.Don't block air inlet or air outlet, otherwise, the cooling or heating capacity will be weakened, even cause system stop operating. 3.Don't apply the cold air to the body for a long time. It will deteriorate your physical conditions and cause health problems.
Zmax.in case necessary, please consult your supply authority for system impedance information. Product Type Zmax Serial No. 0.222 KSIX024-H220 WEEE Warning Meaning of crossed out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Name of Each Part ★ Indoor Unit Air inlet Indoor Unit 、 1 Front panel 、 2 Air filter 、 3 Handling switch 、 4 Louver Air outlet 、 5 Signal receptor 6、Remote controller 7、Drain hose 8、Refrigerant gas/ liquid pipe ★...
Operation ★ Remote controller operation See "air conditioner remote controller instruction " ★ Manual operation ☆ Manual operation When the remote controller does not work or can not be found, please follow these steps: 1.As the unit is operating, you can press the "Auto button" to stop operating.
Notices To prevent injury and property damage, Please pay attention to these following before operating the air conditioner. ★ Checking before operation 1.Make sure that the earth wire is connected safely and reliably. 2. Make sure the filter net is properly fixed. 3.
4. Clean air filters and other parts. 3. Take out the batteries from the remote controller. Troubleshooting Check the following before requesting on service centre of Klimaire if the malfunction occurs. Tr ouble shooting Phenomenon Has the power been shut down?
Page 11
In case the following situation, please immediately stop all operations and cut off the power supply, then contact with service centre of Klimaire. The fuse and switch often breaks. Carelessly splash water or something into air conditioner.
Installation Guide ★ Guide for customer 1.Please read the instructions carefully before installation of the air-conditioner. 2.The installation should be carried out by specialists. 3.Installation the air-conditioner and connecting the pipe and wires must be strict to reference the instructions. 4.The wiring must be done by qualified electrician according to the electrical safety requirements.
Selection of the installing position ★ Indoor Unit ● There is no heating and steaming source nearby. Ceiling clearance above 6 in ● No obstacles for installing position nearly. ● Keep good air circulation. ● Convenient to adopt measures to reduce noises. Side clearance above 6 in ●...
Installation of the indoor unit ●First make changes to wall and make sure that is hard and secure. Using four " + " type screws to fasten the installation board onto the wall. Keep it water lever horizontal direction and perpendicular in vertical direction. Otherwise it might cause water drops when air-conditioner is running cooling operation.
●Arrange the connection pipes, cable, outflow tube according to the figure , then connect the drain pipe to the draining hole. ●Use insulation sleeve to warp the position of connection pipe and indoor unit, then wrap the insulating tape on the sleeve to avoid condensate water. ●Fasten connection pipes, cables and drain pipe together by plastic strap.
Pipe connection ● Connect the pipe to the unit: point to the center of pipe and fasten by wrench until it is tightly The size of pipe Torque fastened, the fastening 18N.m 6.35mm( Pipe Indoor unit direction is in the 13.3 lb-ft Connection screw following picture.
★ Expelling the air in the pipes and the indoor unit Expelling the air: humid air in the Outdoor unit refrigerating system might cause trouble of compressor. ● Take off the cover from the stop valve and T-branch valve. ● Take off the auxiliary cover from the To power T-branch valve.
Electrical connection ● Unscrew the screw, take off the control panel cover from the unit. ● Connect the cable to their terminals according to their number. ● The grounded wire connection: 1.loosen the grounded screw of electrical shelf. 2.Connect the grounded wire with the grounded screw Cover then setscrew in the "...
Test running ● Make sure that pipes and wires are connected. ● Make sure that liquid side valve and air side valve both are completely open. 1. The connection of power source ● Connect the wire to independent power source socket. ●...
Page 20
The Klimaire logo is a registered Trademark of Klimaire Products inc. Copyright 2014 Klimaire Products Inc. 2190 NW 89 Place, Doral, FL 33172 - USA Tel: (305)593-8358 Fax (305) 675-2212 www.klimaire.com sales@klimaire.com The design and specifications are subject to change without prior notice for product...
Need help?
Do you have a question about the KSIX024-H220 and is the answer not in the manual?
Questions and answers