WaterFurnace TPCC32U01 Instruction Manual

WaterFurnace TPCC32U01 Instruction Manual

Color touchscreen communicating with humidity control thermostat
Hide thumbs Also See for TPCC32U01:

Advertisement

Instruction Guide:
Color Touchscreen Communicating with Humidity Control Thermostat
TPCC32U01
Color Touchscreen Communicating with Humidity Control
TPCC32U01 (Firmware Version 3.01 and later)
Heat Pump Thermostat User Information
This communicating thermostat communicates via a 4-wire
Modbus protocol and will only operate as a stand-alone
thermostat with the Aurora Control System, or as a zone
thermostat (not the MasterStat) in the IntelliZone2 or IntelliZone2
● 24V zoning system. The thermostat will auto recognize
whether it is connected as a stand-alone thermostat or a zone
thermostat and display the proper set up screens.
Zone Configuration
The thermostat will auto detect that it is attached to the
IntelliZone2 relay panel and will display the screen below. Use
the up/down arrows ▲▼ to select the zone.
If more than one zone is assigned the same zone number an
error will be displayed on the thermostat and MasterStat. After
the initial configuration to change the zone numbers enter the
configuration mode by holding a finger over the Zone number
in the upper left hand corner for 5 sec. Select zone number and
use the up/down arrow to adjust.
*IG1601EW*
IG1601EW 06/16
INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT

Thermostat Operation

Adjusting Temperature
(Temporary Override in Programmable models)
* Displayed if configured as a Zone Thermostat
**Comp SPD and Room Humidity only displayed if configured as a
stand-alone thermostat
Heating Set
Point
Cooling
Set Point
NOTE: Outdoor temperature is only displayed if an outdoor
sensor is installed.
1.
To select a MODE, press the screen button MODE, and
then press the desired operating mode.
2.
Press the blue up or down arrow to increase or decrease the
cooling temperature set point. Press the red up or down arrow
to increase or decrease the heating temperature set point.
Non-Critical Faults
Non-critical faults (error codes) are displayed below the
temperature on the main screen. These faults will clear
themselves if the fault condition corrects itself. Your dealer
should be informed when either a critical or non-critical fault
occurs.
Lockout/Critical Faults
Critical faults will change the top and bottom bars of the screen
red to indicate service needed. The system can be reset by
pressing reset lockout. Some of the faults will clear themselves
if the fault condition corrects itself. Your dealer should be
informed when either a critical or non-critical fault occurs.
Menu
(Screens shown below are for stand-alone thermostat configuration)
Press the Menu button.
1
Time
Date
Zone*
Error Code (If present)
Outside
Temperature
(If installed)
Room
Temperature
Room Humidity**
Mode &
Comp SPD**
Fan Operation
997-012330-14-R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPCC32U01 and is the answer not in the manual?

Questions and answers

Summary of Contents for WaterFurnace TPCC32U01

  • Page 1: Thermostat Operation

    Heating Set Point Room Temperature Room Humidity** Color Touchscreen Communicating with Humidity Control Mode & TPCC32U01 (Firmware Version 3.01 and later) Comp SPD** Fan Operation Cooling Heat Pump Thermostat User Information Set Point This communicating thermostat communicates via a 4-wire...
  • Page 2 INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT If your heat pump has Energy Monitoring installed, the screen If the FAN hasn’t been on for an hour, the fan will start cycling shall be this: based on these times. Default is OFF. The first screen is the amount of time you want the fan to be energized.
  • Page 3: Programming Your Thermostat

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Programming Your Thermostat Advanced Settings (NOTE: This option is not available if configured as a Zone Set Date and Time Thermostat, but is available at the MasterStat.) (NOTE: This option is not available if configured as a Zone Thermostat, but is available at the MasterStat.) NOTE: If this thermostat is installed with an AWL and Time Synchronization is enabled then Date and Time will be updated...
  • Page 4: Sound Volume

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Sound Volume Superboost (Variable Speed Heat Pumps Only) (NOTE: This option is not available if configured as a Zone Adjust the desired sound level of screen buttons when pressed Thermostat, but is available at the MasterStat.) and the desired sound, either beep, one click, or two clicks.
  • Page 5: Installer Information/Advanced Features

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Daily Energy Use screen AWL Time Synchronization - When enabled the AWL will synchronize the thermostat’s date and time with internet time servers. This option by default is disabled. NOTE: setting the proper time zone in the Symphony Portal is necessary for correct operation.
  • Page 6: Installer Settings

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Installer Settings Separate the front and back pieces of plastic. Route thermostat wires through hole in back piece of NOTE: These options are intended to be used by the installer. plastic. Level plastic against wall (for aesthetic value only End users are not advised to change or modify any of these - thermostat need not be leveled for proper operation) and settings.
  • Page 7: Installer Setting Page Two

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Dealer Restart The Restart button is used to load firmware updates and give This screen allows the dealer to input their contact information the capability to reboot the thermostat without cycling power to to be viewed by the homeowner. the heat pump.
  • Page 8: Installer Setting Page Three

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Smart Recovery Installer Setting Page Three (NOTE: This option is not available if configured as a Zone Press NEXT button. It will bring you to the installer setting page three. Thermostat.) Smart recovery is a feature of your thermostat designed to improve comfort by adjusting temperatures to achieve a room temperature by the programmed time.
  • Page 9: Auto Changeover

    INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Offsets Installer Setting Page Four Temperature Offsets – This option allows calibration (or Press NEXT button. It will bring you to the Installer Setting page deliberate miscalibration) of the room temperature four. sensor(s). There are various reasons why the displayed temperature would be adjusted to a higher or lower value.
  • Page 10 INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Communicating/Troubleshooting TPCC32U01*, TPCM32U03A* and TPCM32U04A* Thermostat not (*GSR, GSM, E, YRK) communicating Wire non- Are you using a communicating 8 Is this a variable communicating wire thermostat speed unit? thermostat? to P1 terminal on...
  • Page 11 P7? P1 on ABC Board TPCC32U01 Can you send a picture of the ABC P7 Thermostat P7 on ABC Board Green Plug Review and confirm the...
  • Page 12 INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT NOTES ©2016 WaterFurnace International, Inc., 9000 Conservation Way, Fort Wayne, IN 46809-9794. WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifi cations without notice.