INSTRUCTION MANUAL
Digital Fiber Sensor Amplifier FX-400
Series
MJE-FX411 No.0034-50V
Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
1
PART DESCRIPTION
Operation indicator (Orange)
Stability indicator (Green)
Operation selection switch
Setting switch
Digital display (Green)
Threshold value adjuster (Note)
Threshold value (RUN condition)
Digital display (Red)
Incident light intensity (RUN condition)
2
MOUNTING
Make sure that the power supply is off while connecting
disconnecting the amplifi-
ers and the quick-connection cables.
How to mount the amplifier
Fit the rear part of the mounting section of the amplifier
on a DIN rail.
Press down the rear part of the mounting section of the
unit on the DIN rail and fit the front part of the mounting
section to the DIN rail.
35mm width DIN rail
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the amplifier to remove it.
Note:
Take care that if the front part is lifted without pushing the
amplifier forward, the hook on the rear portion of the mounting section is likely to break.
How to connect the fiber cables
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
Snap the fiber lock lever down.
Insert the fiber cables slowly into the inlets until they
stop. (Note 1)
Fiber
Return the fiber lock lever to the original position, till it
lock lever
stops.
Notes: 1)
In case the fiber cables are not inserted to a position where
they stop, the sensing range reduces. In case of a flexible
fiber, take care that it may bend inside the amplifier, during
insertion.
2)
With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2, insert the single-core fi-
ber cable into the beam-emitting inlet and the multi-core fiber cable into the beam-receiv-
ing inlet. If they are inserted in reverse, the sensing accuracy will deteriorate.
3
CASCADING
Make sure that the power supply is off while adding or removing the amplifiers.
Make sure to check the allowable ambient temperature, as it depends on the
number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure to mount
them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching condition
or the amplifiers are mounted close to each other in cascade, fit them between
the optional end plates (MS-DIN-E) mounted at the two ends.
Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)
When connecting more than two amplifiers in cascade, use the sub cable
(CN-71-C ) as the quick-connection cable for the second amplifier onwards.
When connecting amplifiers not close to each other in parallel, be sure to mount
the optional end plate (MS-DIN-E) at both sides of each amplifier or affix the
communication window seal of the optional amplifier protection seal (FX-MB1) to
the communication windows. For details, refer to the instruction manual enclosed
with the FX-MB1.
When the connector type and the cable type or different LED (red / blue / green)
types are connected in cascade, mount the identical models together.
When this product is used with the other digital fiber amplifiers, be sure to place
this product to the left most position (When you look from the connector side). If
this product is not placed to the leftmost position, this product may not operate
properly.
For mounting and removing the amplifier, refer to '
2
Cascading method
Mount the amplifiers, one by one,
on the DIN rail.
Slide the amplifiers next to each
other, and connect the quick-con-
Main cable (CN-73-C )
nection cables.
(optional)
Mount the optional end plates
(MS-DIN-E) at both the ends to
hold the amplifiers between their
flat sides.
Tighten the screws to fix the end
plates.
Dismantling
End plates (MS-DIN-E)
Loosen the screws of the end plates.
(optional)
Remove the end plates.
Slide the amplifiers and remove
them one by one.
4
I/O CIRCUIT DIAGRAMS
Make sure that the power supply is off while wiring.
NPN output type
Terminal No. of connector type
Cable type / Color code of quick-
connection cable
(Brown) +V (Note 1)
1
Load
(Black) Output
+
12 to 24V DC
3
-
100mA max.
(Note 2)
(Blue) 0V (Note 1)
2
Internal circuit
Users' circuit
PNP output type
Terminal No. of connector type
Cable type / Color code of quick-
connection cable
(Brown) +V (Note 1)
1
100mA max.
(Note 2)
+
12 to 24V DC
3
-
(Black) Output
Load
2
(Blue) 0V (Note 1)
Internal circuit
Users' circuit
Notes: 1)
The quick-connection sub cable does not have +V (brown) and 0V (blue).
The power is supplied from the connector of the main cable.
2)
50mA max., if five, or more, the connector type amplifiers are connected in cascade.
5
SWITCHING OUTPUT OPERATION
The operation selection switch can be used to display different output operations
(L-ON / D-ON) on the digital display.
Fiber
6
THRESHOLD VALUE (SENSITIVITY) AD-
JUSTMENT
Check the incident light intensity [in the digital
display (red)] when a sensing object is placed
in the sensing position.
Check the incident light intensity [in the digital
display (red)] when the sensing object is
removed from the sensing position.
Turn the threshold value adjuster to the
threshold value [in the digital display (green)]
that is the value in between
and
. (The
threshold value is automatically written to the
EEPROM.)
<
Threshold value setting method
>
When the threshold value adjuster is turned clockwise, the threshold value
increases. When the threshold value adjuster is turned counterclockwise, the
threshold value decreases.
(Threshold value)
(Threshold value)
If there is a sufficient level of margin in the incident light intensity, the stability indica-
tor (green) will light up.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
MOUNTING'.
7
MODE SELECTION
Sub cable (CN-71-C )
When the setting switch is pressed and held for 2 sec. or more, 'SET' mode (mode
(optional)
setting screen) is activated.
If the setting switch is pressed while in 'SET' mode, the mode will change.
If the threshold value adjuster is turned while a mode is active, the setting item will change and blink.
When the setting switch is pressed at the item you would like to set, it blinks 3
times and then the setting is confirmed and the mode switches to the next mode.
Slide
If the setting switch is pressed and held for 2 sec. or more or do not press any key for
15 sec. while 'SET' mode is active, the mode will switch automatically to 'RUN' mode.
Mode table
End plates (MS-DIN-E)
(optional)
Factory
Mode
setting
Response time change mode
Emitting intensity selec-
tion mode (Note 1)
Timer setting mode
Digital display inversion mode
Slide
Eco mode (Note 2)
Peak / Bottom hold mode
Terminal
arrange-
Notes: 1) This mode is not incorporated in the blue LED type and green LED type.
2) While the peak / bottom hold mode is ON, the digital display is not turned off even if the
ment diagram of the
Eco mode is set to ON.
connector type
<
>
RUN condition
+V
1
10%
3
Output
Press and hold for 2 seconds or more
0V
2
<
SET condition
>
(
Response time
)
change mode
Terminal
arrange-
ment diagram of the
connector type
1
+V
10%
(
Emitting intensity
)
Output
selection mode
3
(Note 1)
0V
2
(
Timer setting
)
mode
The timer period can be set within the following ranges:
1 to 10 ms: 1 ms units; 10 to 100 ms: 10 ms units; 100 to 500 ms: 50 ms units
500 to 1000 ms: 100 ms units; 1000 to 3000 ms: 500 ms units
Digital display
(
)
inversion mode
(Eco mode)
(Incident light intensity)
Peak / Bottom
hold mode
(Incident light intensity)
<RUN condition>
(Threshold value)
8
KEY LOCK FUNCTION
When the setting switch is pressed and
hold for 5 sec. while in 'RUN' mode, the
key lock function can be set / canceled.
When the key lock function is set to ON,
even if the threshold value adjuster or the
setting switch is operated, '
and the key operation cannot be carried out.
Note: Although the display changes to the indication of 'SET'
condition 2 sec. after pressing the setting switch, keep
pressing the switch. Furthermore, the sensor does not go into the key lock setting from 'SET' condition.
9
FACTORY SETTING
When the setting switch is pressed and held for 10 sec., until '
played while in 'RUN' mode, the all settings are returned to the factory setting.
(For the factory setting, refer to ' Mode table' in '
10
ERROR DISPLAY INDICATOR READINGS
Display
11
SPECIFICATIONS
Model
Description
No.
Item
The response time can be set.
Supply voltage
The light emitting intensity can be switched among four levels.
Power consumption
Timer settings can be select ed; Without timer / OFF-delay timer /
ON-delay timer / ONE-SHOT timer. Also the timer period can be set.
The display on the digital display can be inverted.
If no key is pressed for approximately 20 sec. while in 'RUN' mode, the
digital display turns off automatically. Press the setting switch or move
the operation selection switch to make the display light up again. The
Output
digital display will light up when the threshold value adjuster is turned,
but note that this will also cause the threshold value to change.
If the setting switch is pressed while 'RUN' mode is active, the display
will alternate between the peak hold value and the bottom hold value.
Output operation
(The display will refresh every 2 sec.) The display will return to nor-
Short-circuit protection
mal if any operation other than threshold value setting is carried out.
Response time
Interference prevention
function
Ambient temperature
Ambient humidity
Emitting element
Peak emission wavelength
Material
High speed
Response time: 150 s or less
Cable
Standard
Response time: 500 s or less
Weight
Notes: 1)
FX-412 , with the sensitivity adjuster shaped so that it can be turned manually using
Response time: 4.5ms or less
Long-range
fingers, is also available. However, the cable type is not available for FX-412 .
2)
50mA, the connector type five, or more, amplifiers are connected in cascade.
3)
When the power supply is switched on, the light emission timing is automatically set for
Note: This mode is not incorporated
interference prevention.
Emitting power Hi
4)
in the blue LED type and
The cable for amplifier connection is not supplied as an accessory. Make sure to use the
green LED type.
optional quick-connection cables given below.
Main cable (3-core): CN-73-C1 (cable length 1m), CN-73-C2 (cable length 2m)
Sub cable (1-core) : CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m)
Emitting power Lo
12
CAUTIONS
This product has been developed / produced for industrial use only.
Without timer
Take care that wrong wiring will damage the sensor.
Make sure that the power supply is off while wiring.
OFF-delay
Verify that the supply voltage variation is within the rating.
ON-delay
Take care that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the sensor may get burnt or damaged.
ONE-SHOT
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of
the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power supply is
(The actual display will be '
'.)
switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if 9 to
16 units are connected in cascade: 20m) is possible with 0.3mm 2 , or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
Take care that cable extension increases the residual voltage.
This sensor is suitable for indoor use only.
Avoid dust, dirt, and steam.
<RUN condition>
Take care that the product does not come in contact with water, oil, grease,
organic solvents, such as, thinner, etc., strong acid or alkaline.
This sensor cannot be used in an environment containing inflammable or explosive gases.
Never disassemble or modify the sensor.
(Peak value)
(Bottom value)
The changes to the settings are written to the EEPROM, but because the
EEPROM has a limited service life, you should avoid changing the settings any
more than 1 million times.
13
INTENDED PRODUCTS FOR CE MARKING
The models listed under "
As for all other models, please contact our office.
<RUN condition>
Contact for CE
<Until June 30 ,2013>
Press and hold
Panasonic Electric Works Europe AG
for 5 sec. (Note)
(Set to ON)
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
' is displayed
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
(Set to OFF)
' is dis-
7
MODE SELECTION'.)
Error description
Measures
The load has short-circuited
Turn off the power, then check the load.
and excess current is flowing.
Communication error has oc-
Check if the mounted amplifiers are in close contact
with each other.
curred at time of connection.
Connector type
Cable type
Type
Red LED
Blue LED
Green LED
Red LED
Blue LED
Green LED
NPN output (Note 1)
FX-411
FX-411B
FX-411G
FX-411-C2
FX-411B-C2
FX-411G-C2
PNP output
FX-411P
FX-411BP FX-411GP
FX-411P-C2
FX-411BP-C2
FX-411GP-C2
12 to 24V DC 10% Ripple P-P 10% or less
<Red LED type>
<Blue LED type / Green LED type>
Normal operation: 960mW or less
Normal operation: 720mW or less
(Current consumption 40mA or less at 24V supply voltage)
(Current consumption 30mA or less at 24V supply voltage)
ECO mode: 840mW or less
ECO mode: 580mW or less
(Current consumption 35mA or less at 24V supply voltage)
(Current consumption 24mA or less at 24V supply voltage)
<NPN output type>
<PNP output type>
NPN open-collector transistor
PNP open-collector transistor
Maximum sink current: 100mA (Note 2)
Maximum source current: 100mA (Note 2)
Applied voltage: 30V DC or less
Applied voltage: 30V DC or less
(between output and 0V)
(between output and +V)
Residual voltage: 1.5V or less
Residual voltage: 1.5V or less
[at 100mA (Note 2) sink current]
[at 100mA (Note 2) source current]
Light-ON or Dark-ON, selectable with switch
Incorporated
FAST: 150 s or less, STD: 500 s or less, U-LG: 4.5ms or less selectable with switch
Incorporated [up to four fibers can be mounted adjacently (However,
U-LG mode is eight fibers)
-10 to +55
(If 4 to 7 units are connected in cascade: -10 to +50 ,
if 8 to 16 units are connected in cascade: -10 to +45 )
(No dew condensation or icing allowed), Storage: -20 to +70
35 to 85% RH, Storage: 35 to 85% RH
Red LED
Blue LED
Green LED
Red LED
Blue LED
Green LED
650nm
470nm
525nm
650nm
470nm
525nm
Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Setting switch: Heat-resistant ABS, Threshold value adjuster: Polycarbonate
0.3mm
2
3-core cabtyre cable, 2m long (Cable type only)
20g approx.
60g approx.
CN-73-C5 (cable length 5m)
CN-71-C5 (cable length 5m)
11
SPECIFICATIONS" come with CE Marking.