Page 1
Wall Mounted FCU DC Installation and Owner's manual and Information requirements MUP-W7 CL04315 to CL04318 English www.mundoclima.com www.mundoclima.com...
Page 2
CONTENT INSTALLATION MANUAL ..................... 3 OWNER'S MANUAL .....................11 REMOTE CONTROLLER .................... INFORMATION REQUIREMENTS ................29 /DWKZd Ed Thank you for selectiong super quality Air Conditiones. To ensure satisfactory operation for many ears to come, this manual should be read carefully before the installation and before using the air conditioner. After reading, store it a safe place.
INSTALLATION MANUAL Read This Manual: Please read this manual carefully before installing and using the unit. Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner.
Page 4
Installation manual Wall mounted FCU DC Use the attached accessories parts and specified parts CONTENTS PAGE for installation. otherwise, it will cause the set to fall, water leakage, electrical shock fire. PRECAUTIONS..................4 Install at a strong and firm location which is able to INSTALLATION INFORMATION..............5 withstand the set' s weight.
Installation manual Wall mounted FCU DC 2. INSTALLATION INFORMATION CAUTION Ground the air conditioner. To install properly, please read this "installation manual" at Do not connect the ground wire to gas or water pipes, first. lightning rod or a telephone ground wire.Incomplete grounding may result in electric shocks.
Installation manual Wall mounted FCU DC 3. ATTACHED FITTINGS Please check whether the following fittings are of full scope. If there are some spare fittings, please restore them carefully. NAME SHAPE QUANTITY FUNCTION 1. Screw ST3.9x25 for installation board Secure the installation board 2.
Installation manual Wall mounted FCU DC 4. INSPECTING AND HANDLING THE UNIT 5.2 Drilling A Hole and Mounting Installation Board At delivery, the package should be checked and any damage should Installation Board and Its Direction (unit: mm) be reported immediately to the carrier claims agent. MUP-07/09/12-W7 When handling the unit, take into account the following: mounting board of indoor unit...
Page 8
Installation manual Wall mounted FCU DC When connection extension drain hose,insulate the False installation connecting part of extension drain hose with a shield pipe mounting board of indoor unit Wall Shield pipe horizontal line Extension drainhose Drain hose Fig.5-7 Fig.5-4 Connection pipe mounting board of indoor unit...
Installation manual Wall mounted FCU DC 6. WATER PIPE INSTALLATION Piping and bandaging Wind the connective cable, drain hose and wiring with tape securely, evenly as shown below. 6.1 Material and Size of the Piping Table 6-1 Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room.
Installation manual Wall mounted FCU DC 7. WIRING CHART 7.1 Terminal Board Diagram Please refer to the indoor unit wiring diagram for the wiring. The power supply specifications are as following, see table 7-1. If the capacity of wire is too small, it may result in overheating on the wire and cause the machine burned out.
OWNER´S MANUAL Read This Manual: Please read this manual carefully before installing and using the unit. Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner.
Owner's manual Wall mounted FCU DC Air inlet Air outlet Inlet pipe Return pipe Drain pipe Infrared signal Temperature receiver display Operation lamp Timer indicator Display panel Bottom plate Faceplate Display panel Horizontal air deflector Remote controller NOTE All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model).The actual shape shall prevail.
Owner's manual Wall mounted FCU DC Do not insert fingers, rods or other objects into the air CONTENTS PAGE inlet or outlet. When the fan is rotating at high speed, it will cause injury. IMPORTANT SAFETY INFORMATION............9 PARTS NAMES..................Never use a flammable spray such as hair spray, lacquer or paint near the unit.
Owner's manual Wall mounted FCU DC 2. PARTS NAMES After a long use, check the unit stand and fitting for damage. If damaged, the unit may fall and result in injury. The air conditioner consists of the indoor unit, the connecting pipe and the remote controller.
Owner's manual Wall mounted FCU DC 6. MAINTENANCE 4. HINTS FOR ECONOMICAL OPERATION The following should be noticed to ensure an economical operation. CAUTION (Refer to corresponding chapterfor details) Before you clean the air conditioner, be sure the power supply is off. Adjust the air flow direction properly to avoid winding toward your body.
Page 16
Owner's manual Wall mounted FCU DC 7. FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES Symptom 1: The system does not operate The air conditioner does not start immediately after the ON/OFF button on the romote controller is pressed. If the operation lamp lights, the system is in normal condition.To air filter prevent overloading of the compressor motor, the air conditioner starts 3 minutes after it is turned ON.
Owner's manual Wall mounted FCU DC 8. TROUBLESHOOTING 8.1. Troubles and causes of air conditioner Table 8-1 If one of the following malfunctions occur, stop operation, shut Malfunction code Malfunction off the power, and contact with your dealer. DC motor malfunction The operation lamp is flashing rapidly (twice every second) This lamp is still flashing rapidly after turn off the power and turn T2 evaporator sensor malfunction...
Page 18
Owner's manual Wall mounted FCU DC 8.2. Troubles and causes of remote controller Before asking for serving or repairing , check the following points. Table 8-3 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
REMOTE CONTROLLER Please read this manual carefully before installing and using the unit.
Page 20
Remote controller Wall mounted FCU DC Please remove the nearby electronic device for they may affect the Safety precautions performance of remote controller. If necessary, contact the local Midea The following contents are stated on the product and the operation service centre or technical support centre.
Page 21
Remote controller Wall mounted FCU DC MODE: Once pressing, running mode will be selected in ECO: Activate or turn off economic operation mode. It is the following sequence: suggested to turn on this function when sleeping. (Only available when remote controller is used with corresponding AUTO COOL HEAT...
Page 22
Remote controller Wall mounted FCU DC 1.4. Operation instructions Set TIME ON and TIME OFF simultaneously 1. Set TIME ON according to procedures 1 and 2 specified in Install and replace batteries TIME ON operation Install 2 pieces of 7# alkaline batteries. 2.
Page 23
Remote controller Wall mounted FCU DC TIMER 2. Wireless remote controller RM02A Under the OFF state, press this button, TIMER ON are ligtened. continue to press TIMER button, the time will increase by 0.5 ● The outline figure on cover is for reference only, hour.
Page 24
Remote controller Wall mounted FCU DC 2.3. Names of indicators and their 2.4.2. Auto operation (Normal) functions AUTO operation Timer ON/OFF TEMP Transmitting ON/OFF AUTO MODE Lock display TIMER ON TIMER OFF FAN SPEED FAN SPEED ON/OFF AUTO Lighting COOL Running Temperature FOLLOW ME...
Remote controller Wall mounted FCU DC Follow me function Auto heat recycling mode function Function instruction instruction DRY E •A•H FOLLOW ME Function ΔT Temperature difference, means the different temperature This air conditioner has follow me function, Fig.5-4 between the indoor temperature (Tf) detected by the remote when this function is operated, the remote controller and the remote controller setting temperature (Ts).
Page 26
Remote controller Wall mounted FCU DC Setting timing OFF 3. Wired remote controller KJR-29B TIMER OFF TIMER OFF TIMER OFF TIMER TIMER 7KLV PDQXDO JLYHV GHWDLOHG GHVFULSWLRQ RI WKH SUHFDXWLRQV COOL COOL COOL WKDW VKRXOG EH EURXJKW WR \RXU DWWHQWLRQ GXULQJ RSHUDWLRQ FAN SPEED FAN SPEED FAN SPEED...
Need help?
Do you have a question about the MUP-W7 and is the answer not in the manual?
Questions and answers