Page 1
2017831A (sw pkg 3.0.x) Reference Guide ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506–1402 U.S.A. WORLD AUTHORITY IN SEPARATION TECHNOLOGIES...
Page 3
CAUTION Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. CAUTION The metal detector is heavy. Do not lift nor support the metal detector by hand/manually.
Page 4
To avoid injury or damage to the equipment, all electrical installations are to be performed by qualified and competent personnel authorized by Eriez Manufacturing Company. All electrical installations are to be in compliance with local safety codes. Ensure that all materials used in the installation of the equipment are suitable and appropriate for purpose.
Page 5
Eriez Manufacturing Company. CAUTION The XTREME metal detector is not designed nor intended for operation in environments classified as hazardous locations/zones. Do not operate the XTREME metal detector in areas where the possibility of explosions or fires exists.
Page 6
CAUTION When cleaning the metal detector surfaces, use appropriate personal protective equipment (PPE) for any physical/chemical/biological hazards that may exist due to the end user’s production environment. Avoid contact with contaminants on or around the metal detector. Pressure Wash and sanitize metal detector surfaces when maintenance is required.
Page 7
Handling Pg.7 Basic lifting and moving instructions Specifications Basic product specifications and safety information Pg.9 Mechanical Mechanical installation instructions Pg.13 Electrical Electrical Installation Instructions Pg.23 User Interface Every screen explained and easy to use how-to guides. Pg.33 PLC Interface PLC interface setup instructions Pg.83 Maintenance Pg.97...
Page 9
Radio Frequency (RF) emissions have been tested to the requirements of FCC 47CFR Part 18, and CISPR 11/EN 55011 (Class A, Group 2). The Eriez Xtreme Metal Detector generates an electromagnetic field which has the potential to escape. This field may interfere with nearby radio frequency equipment.
Page 10
Larger metal detectors may have eyebolts preinstalled at the factory. When handling with the eyebolts ensure loads are never applied perpendicular to the shank of the eyebolts; they will break. CAUTION The metal detector is heavy. Do not lift nor support the metal detector by hand.
Page 11
SPECS SUPPLY, MAINS, VOLTAGE The Xtreme Metal Detector will operate from AC supply voltages over the range of 100 to 240 VAC RMS, 50 or 60 Hz. Mains supply voltage fluctuations shall not exceed ±10% of the nominal value.
Page 12
Power at L1B and L2B passes through the circuit breaker switch located on the left side of the control housing. There are five programmable “Form A” (SPST-NO) solid state relay outputs rated at 500mA up to 40 VDC. Out 4 (K6) Out 1 (K9) Out 5 (K5) Out 2 (K8)
Page 13
Additional information on how to setup Overhead A-B is located in the wiring section of this manual. SPECS INPUTS The Xtreme Metal Detector has eight configurable inputs that can be set to “Active High” or “Active Low”. Input Voltage -“High” = 10 to 30 VDC -“Low”...
Page 14
RELATIVE HUMIDITY 0 TO 95% MAXIMUM OPERATING ALTITUDE 2000 meters (6561 feet) SPECS PRODUCT VELOCITY Minimum: 2 ft/min (0.6 m/min) Maximum: up to 3000 ft/min (914 m/min) Note: Actual maximums are dependent on aperture size. For gravity-fed vertical metal detectors, product velocity is determined by free-fall distance. The maximum free-fall distance is dependent on the system design, especially the distance between the sensing head and reject valve.
Page 15
The metal detector contains several components which must be physically mounted to a conveyor or suitable stand. These include the sensing head, the control (if remote), and other devices such as a tachometer. Most Xtreme Metal Detectors sensing heads have an integral control, thus simplifying installation and wiring.
Page 16
Operator convenience should also be evaluated. Ensure installation guidelines are followed and met before the final location is selected. If there are any questions, please contact Eriez for assistance. METAL FREE AREA The metal detector monitors an electromagnetic field to detect metal. This field is predominantly contained within the aperture of the detector.
Page 17
Figure 2 MECH H = smaller tunnel dimension (typically height) ELECTRICAL CURRENT LOOP The most frequent problem encountered in metal detector installations is false tripping caused by intermittent electrical current loops. The electromagnetic field dissipates in strength with distance to a point that metal outside the “metal free” area will not cause false detections. Since the field is time varying, it will generate small electrical currents in conductive paths (metalwork) beyond the metal free area.
Page 18
Likewise, the cross-members of the conveyor framework represent possible break points. Over time, these connections can work loose or corrode and cause “make and break” connections due to vibration. The interruption or change of the current is a source of electromagnetic interference detectable by the metal detector.
Page 19
Insulating Shoulder Washer Insulator Material (Neoprene or Fiberglass) Figure 6 shows the method recommended by Eriez; this is also the simplest method. It requires the bearing block on the end opposite the motor to be replaced with a plastic/non-metallic one.
Page 20
Figure 6 Non-metallic/Plastic Bearing Block MECH All three insulating methods are reliable. However, it only takes a small metal shaving or burr to cut through and short-circuit the insulators. A check of the integrity of the insulation with an ohmmeter will ensure everything is correctly installed. Insulating either end of the shaft will prevent current loops but will also prevent testing with an ohmmeter.
Page 21
PERMANENT CURRENT LOOPS Permanent conduction paths (i.e. cross members) in the conveyor frame should be welded securely to provide a reliable path for any current that may be created. Bolted construction may eventually degrade, and is not recommended unless designed and executed by experts in metal detector conveyor construction.
Page 22
Four insulating mounting feet are supplied with the metal detector. These mounting feet must be used to ensure proper operation (Figure 8). All four mounting feet must sit flat on the supporting structure. Do not draw the feet down to the structure by tightening the mounting bolts, as this will put uneven stresses on the sensing head shell which in turn may cause instabilities in operation.
Page 23
A proven, trouble free choice for metal detector conveyor belts are modular plastic conveyor belts. Eriez recommends and uses this option as they are easily maintained and faulty sections can be changed out quickly. Conductive plastic components, belts, and metallic hinge pins or rods must be avoided.
Page 24
The slider bed must not touch the aperture liner. The slider bed should be made of static-resistant non-metallic material. Anti-static UHMW and phenolic are acceptable choices. Eriez has designed and incorporated a static-dissipative food grade plastic slider bed into our standard and custom metal detector conveyor systems. Most solid plastics cannot be used because these materials tend to generate static electricity as the conveyor belt slides across.
Page 25
INTRODUCTION CAUTION Electrical installation should be performed only by trained electrical service personnel, authorized by Eriez. Installation wiring should conform to National Electrical Code, or other applicable standards as required by local regulations. All electrical connections are made within the control enclosure. Figure 2 ( ) shows the IOC PCB and the electrical connections to the circuit board.
Page 26
The wiring from the mains supply panel to the metal detector should be a minimum of 14 AWG, and should include a dedicated earth ground wire for safety and proper operation of the metal detector. The power wiring should be run in a dedicated conduit. The best insurance against electrical noise and false tripping is to run a separate circuit to the metal detector from the main power bus.
Page 27
CAUTION Verify input power requirements before making any connections. The Xtreme Metal Detector has four mechanical and five solid state relays, for a total of nine programmable outputs, each with one set of contacts. ELEC There are four programmable “Form C”...
Page 28
There are five programmable “Form A” (SPST-NO) solid state relays each rated at 500mA up to 40 VDC. These relays can be wired as NPN or PNP. The output can be set to NO or NC under normal running conditions. If +24V is used to power the relays, the maximum current available is 2A.
Page 29
TACHOMETER INPUT Applications having variable speed product flow and requiring automatic reject timing use this input. A tachometer is used to allow the metal detector control to monitor product speed, and reject according to the distance the product has traveled rather than according to elapsed time since detection.
Page 30
CONDUIT Wiring to and from the metal detector should be routed through conduit. High voltage wiring for the power supply and reject devices should not be located in the same conduit as low power sensor wiring (i.e. tachometer and reset switch). Keep all metal detector wiring separate from electrical supplies carrying heavy or switched loads.
Page 32
FIGURE 3: INFORMATION TOWER NOTE: The light indicators on the Information Tower are configurable via the “Output Configuration” Screen. (default Fault Indicator configuration shown) Warning Indicator Healthy Indicator Reject Indicator Not Used Buzzer Volume Adjustment ELEC...
Page 35
MENU MAP PASSWORD LEVEL HEIRARCHY E – Engineer = 4444 S – Supervisor = 3333 Q – Quality Control = 2222 Task Bar O – Operator = 1111 NOTE: Symbol in upper right corner denotes minimum password level required to view that screen. Current User Login Faults...
Page 36
TASK BAR NOTE: The Task Bar is accessible from all screens. Login Indicates Indicates Name of Time and Date Home Button Level/User Touch Detector is in Current Set via Display Home Pg.38 User Login Screen is Detect Screen Settings Pg.51 Pg.36 depressed Forward and...
Page 37
Fault Fault Description Fault Type Configuration for Pg.46 more options Fault and Warning Eriez Contact Clear Faults Button Indicator Buttons Information Requires “Engineer Level” Press these buttons to see the current faults NOTE: If a Fault and Warning have both occurred the Fault Indicator...
Page 38
USER LOGIN Forward and Back Default Users Buttons for Enter a Password See User Management Additional User 4 Digit Maximum Screen for More Options Name pages Pg.52 NOTE: Entering an incorrect password will revert you to the “View” level. The “View” level has no user functionality.
MAIN MENU Displays Graphing Features and Commonly Used Functions Pg.38 Adds/Deletes/Modifies Products and Selects “Running Product” Pg.39 Configures Faults/Inputs/Outputs/Network Requires “Engineer Level” Pg.40 Modifies Display and User Login Options Pg.41 Displays Circuit Board Diagnostic Information Requires at least “Supervisor Level” to view - see Pg.42 Displays software versions Pg.43...
Page 40
HOME SCREEN Zoom Zoom View Event/Reject Log and Verification Info Product Signal (red) View and Edit Adds, Deletes, Boundary, Reject Modifies Products Setup, Belt Speed, and Selects Frequency “Running Requires at least Product” Boundary “Supervisor Level” (green) Pg.39 to view Zooms to Product Starts and Pauses Signal or...
Page 41
PRODUCT SETUP List of Products (up to 100 products Product X can be stored) Makes an Exact Copy Press to Make of Selected Current Selection the Product Running Product Runs New Product Denotes Running Wizard Product Pg.63 Deletes Selected Product Allows Editing of Product Performs Backup of System Requires “Engineer Level”...
Page 42
I/O SETUP Allows Enable/ Disable of Faults and Selection of Priority Level Pressing the I/O Setup Button Displays the Submenu to the Right Sets up Output Sets up Network Sets up Input Devices Sets up PLC Settings Devices Settings NOTE: This screen requires “Engineer Level” to view.
Page 43
HMI SETUP Allows You to Change YOUR Password Allows Addition, Allows Adjustment of Date/Time, Pressing the HMI Deletion, and Changes Screen Brightness, and Setup Button to Users Password Timeout Displays the Requires at least “QC Requires at least “QC Level” to Submenu to the Right Level”...
Page 44
DIAGNOSTIC SCREEN Troubleshooting Green Light Indicates Feature for Use with Remote Support Option is Factory Technician Available. Troubleshooting Feature for Use with Factory Technician Default is ON NOTE: Remote Support capability requires that a static IP Address be assigned to the Metal Detector and a Secure Gateway (Purchased Separately) be connected to your LAN..
Page 45
ABOUT SCREEN 2015 Current Software Pressing “OK” will Versions and Eriez Contact Information return you to the Detector Serial “Main Menu” Number...
Page 46
QUALITY CONTROL SCREEN Shows Verification Overview View Event Log Information when Enabled Press to Enter Press to Enter Verification Verification Details Scheduling Requires at Pg.57 least “QC Level” Pg.56 Initiates Verification Shows the Next Shows Last Test Scheduled View Reject Log Verification Requires at least Verification...
Page 47
PRODUCT SETTINGS Edit Product Name Edit Product Speed Ensure physical product speed matches ( Pg.69 Select Frequency (Engineer Only) Allows Manual Setup Reject Performs Auto Editing of Devices and Timing Setup of Boundary (Engineer Only) Boundary Settings NOTE: This screen requires at least “Supervisor Level” to view. Some features of this page require “Engineer Level”.
Page 48
FAULT CONFIGURATION Sets Enables/Disables Notification Notifications Level (Warning/Fault) NOTE: If a Fault and Warning have both occurred, the Fault Indicator will take precedence over the Warning Indicator. NOTE: This screen requires “Engineer Level” to view.
Page 49
INPUT CONFIGURATION Sets Function Press to Edit Press to Edit Sets Input as of Selected Input Debounce Active Low or Input Timing Description High NOTE: This screen requires “Engineer Level” to view.
Page 50
OUTPUT CONFIGURATION Sets Output as Sets Function Press to Edit Normally Open of Selected Output or Normally Output Description Closed “Reject” functionality is limited to “Reject Timer” or “Overhead A-B”. NOTE: This screen requires “Engineer Level” to view.
Page 51
NETWORK CONFIGURATION Edit Gateway Edit Static IP Address Edit Subnet Mask Updates and Applies Changes to Settings NOTE: This screen requires “Engineer Level” to view.
Page 52
PLC CONFIGURATION Edits Product Number Connection Status of Select Product Edits PLC Networking IModule and PLC to Edit Number Settings and Updates to (Red= Not Connected) for PLC Use take effect (Green= Connected) NOTE: This screen requires “Engineer Level” to view.
Page 53
DISPLAY SETTINGS Enables/Disables Password Timeout Feature If enabled, sets the amount of time before system defaults to “View” level and returns to Home Screen Adjusts Screen Edits Time and Brightness Date NOTE: Time is set using a 24 hour clock. NOTE: This screen requires at least “QC Level”...
Page 54
USER MANAGEMENT Select to Show Users Passwords Only shows passwords of logged in Creates New Deletes User Edits User user and those users with password User levels below the current user NOTE: A user may Create or Delete users at their level and below. A user may Edit their own information or users below their level.
Page 55
USER SETTINGS Updates Password Allows User to Change Once Current, New, Current Password and Confirm Entries Have Been Filled...
Page 56
EVENT LOG SCREEN Date/Time User That If Event Caused a Change, Event Stamp of Performed Old and New Settings Will Label Event Event Be Displayed Clear Event Log Turn On/Off Event Log Will Export Log to USB Stick Requires at least Hold 1000 Auto Refresh of Requires at least “QC Level”...
Page 57
REJECT LOG SCREEN Type of Detection (Standard is always “B”) Magnitude of Signal Detected Phase of Signal Detected Magnitude of Signal compared to Detect Threshold Reject Log Will Export Log to USB Stick Clear Reject Log Turn On/Off Hold 1000 Requires at least “QC Level”...
Page 58
VERIFICATION DETAILS Selects Metal Size (in Millimeters) to Be Used for Verification Sets the number of Enable/Disable Metal times to test each Selects Product to Set Type Verification for metal during Verification Metal Sizes the Selected Product verifcation NOTE: This screen requires at least “QC Level” to view.
Page 59
VERIFICATION SCHEDULE Sets Reference Time for Verification References Next Interval Verification from Start When Enabled or Last Sets Time Verification when Disabled Between Scheduled Verifications Sets the Amount of Time After Being Alerted That User Has to Perform a Verification before a Fault Occurs Verification Is...
Page 60
VERIFICATION SCREEN Initiates Verification Procedure for the Associated Metal Type Indicates verification check passed Indicates verification check failed Indicates verification check has not been performed Press to Mark Verification as Complete Only visible after all metal verifications have been completed. NOTE: This screen requires at least “QC Level”...
Page 61
BOUNDARY SETUP Sets Phase Angle of Boundary in Degrees Sets Length of Boundary Starts Auto-Setup Feature Sets Width of Boundary Shifts Boundary about Length Axis Shifts Boundary about Width Axis Toggles Toggles between Unipolar and Between Ellipse Bipolar Modes. Leave on Unipolar and Rectangle unless Directed by Factory to Boundaries...
Page 62
REJECT SETUP Sets Travel Sets On/Off Time from Timing for Detection to Reject Device When Reject Fires Advanced Reject Setup Options Pg.61 Triggers Graph Selects Reject Used to Setup Copies Selected to Acquire Timer to Scaling of Timers Settings Timing Data on View/Edit Timing Window Next Reject...
Page 63
ADVANCED REJECT SETUP Selects Exit Manual or Advanced Automatic Reject Reject Setup Reset Is There Space between Duration If enabled, Tachometer Products? Based on Fault occurs when no (Yes/No) Internal Timer tach pulses are received or Tach within this time period. Travel Time Is device Is an Index...
Page 64
“HOW TO” GUIDE PRODUCT USER Perform Setup Output New Product Setup New User Verification Check Device Wizard Export Report Setup Input Switch Users Clone a Product Logs Device Setup Product Rename Counting Product Setup Product Setup Reject Boundary Device Change/Run a Setup Remote Product Support...
Page 65
“HOW TO” RUN NEW PRODUCT WIZARD Product X Product X Ensure the belt is running and the product you are setting up is nearby. 1. From the “Home Screen” press “Product Setup”. 2. Press “New” and rename your product. 3. Select Frequency or copy from the list below. 4.
Page 66
“HOW TO” CLONE A PRODUCT 1. From the Home Screen press “Product Setup”. 2. Press Clone. 3. Select Product from the list on the left to clone. Once selected, it will be visible under “Current Product Selection”. Press “OK”. 4. Rename your new product and it will display in the Product Name list. (See “How To” Rename a Product on the following page)
Page 67
“HOW TO” RENAME A PRODUCT Product X Product X Product X Product X 1. From the “Product Setup” Screen select the product you wish to edit and press “Edit”. 2. Press the name of the product at the top of the table to rename the product. 3.
Page 68
“HOW TO” SETUP A PRODUCT BOUNDARY 1. From the “Home Screen” select “Running Product Settings”. 2. Select the desired frequency range. 3. Edit product speed. See “HOW TO EDIT PRODUCT SPEED” for more details if Pg.69 needed, on 4. Press the “EZ” button. 5.
Page 69
“HOW TO” CHANGE/RUN A PRODUCT Product X Product X Product X 1. From the “Product Setup” Screen select the product you wish to run. 2. Press the “Running Man” button. 3. The Home Screen will now be displayed with the new running product.
Page 70
“HOW TO” EDIT PRODUCT SETTINGS Product X Product X Product X Product X Product X 1. Select “Product Setup”. 2. Select product you wish to edit and press the “Edit” button. 3. Edit product speed. See “HOW TO EDIT PRODUCT SPEED” for more details if Pg.69 needed, on 4.
Page 71
“HOW TO” EDIT PRODUCT SPEED 1. From the Product Settings screen, or from the New Product setup wizard, press the current speed setting. 2. If automatic belt speed control is installed, select the desired belt speed using the slider bar or numerical entry box as shown.
Page 72
“HOW TO” SETUP REJECT TIMING 1. From the “Advanced Reject Settings Screen” make the appropriate selections based on your product. Note that not all options may be available depending on the inputs and outputs that have been setup. 2. In this example an index device(i.e. photo eye) is NOT being used. Set the desired “Travel” and “On Time”.
Page 73
“HOW TO” COPY TIMER SETTINGS Product X Ensure you have selected and are “running” the product you wish to copy the timer from. 1. From the “Home Screen” select “Running Product Settings”. 2. Select “Reject Setup” and pick the timer you wish to copy. 3.
Page 74
“HOW TO” PERFORM A BACKUP Product X Product X 1. From the “Home Screen” press “Product Setup”. 2. Press “Backup Restore”. 3. Select Backup and press “OK” 4. Select appropriate drive to backup to. If using a “USB Stick” select “External Drive”.
Page 75
“HOW TO” SETUP A NEW USER 1. From the “Main Menu” select “HMI Setup” then “User Management”. 2. Press the “New” button. 3. Input the new user’s name and desired password. 4. Select the user login level from the dropdown. 5.
Page 76
“HOW TO” SWITCH USERS 1. From the Task Bar press the User Login button. 2. Select the User Name from the List and enter the password. 3. Press “OK”. 4. Verify User Login Name appears on User Login button.
Page 77
“HOW TO” SETUP AN OUTPUT DEVICE 1. From the “Main Menu” select “I/O Setup” then “Output Configuration”. 2. Select the output that the “output device” is wired to. 3. Select output device function. The “Reject” output has limited functionality and is the primary reject output.
Page 78
“HOW TO” SETUP AN INPUT DEVICE 1. From the “Main Menu” select “I/O Setup” then “Input Configuration”. 2. Select the input that the “input device” is wired to. 3. Select the device function (i.e. tachometer, overhead, etc..). 4. Enter a description for the input device. 5.
Page 79
“HOW TO” SETUP PRODUCT COUNTING 1. From the “Main Menu” select “I/O Setup” then “Input Configuration”. 2. Select the input that the photo-eye is wired to. Note: It is possible to use one photo-eye for two functions (e.g., “Reject Index” and “Product Counter”); in this case, the photo-eye must be wired to two inputs on the IOC circuit board (e.g., “In3”...
Page 80
“HOW TO” SETUP A REJECT DEVICE Ensure reject device and all associated devices (i.e. photo eye, tachometer, etc…) are wired into the control. See Electrical Installation section. Configure Input and Output Devices. Configure “Advanced Reject Settings” page. Setup reject timing. “HOW TO”...
Page 81
“HOW TO” SETUP REMOTE SUPPORT 1. Connect “Secure Gateway” (Purchased Separately) and Metal Detector to your Intranet/LAN as seen below (ensure outbound port 5721 on your firewall is open) Note: The “Secure Gateway” is not designed for protection from liquids. It must be installed in an area that is not subject to wash- down.
Page 82
“HOW TO” PERFORM A VERIFICATION CHECK Test Count. Test Count. Only shown if Only shown if Tests per count Tests per count is greater than 1 is greater than 1 1. On the task bar press “Verification Needed”. 2. Press the metal type you wish to test. 3.
Page 83
“HOW TO” EXPORT REPORT LOGS 1. Ensure a USB drive is inserted into the USB connector. 2. From the “Home Screen” select “Quality Control”. 3. Select which Log you would like to view and export. 4. Press export. You now have the option to rename the file.
Page 84
THE DETECTION BOUNDARY EXPLAINED 1. Phase adjustment(degrees). Should align with product signal. 2. Length adjustment(uV). Should run parallel to product signal length. 3. Width adjustment(uV). Should run parallel to product signal width. 4. Shift about the length axis in parallel with selected phase.
Page 85
Between Xtreme Metal Detector and PLC INTRODUCTION A PLC can be connected to the Xtreme metal detector by means of the factory installed PLC Interface Module. This module allows the PLC to set and retrieve the running product number. It can also retrieve metal detector status information.
Page 86
3. Assign product numbers (1, 2, 3 …) to all products that will be remotely selected from the PLC. Assigning 0 to any product makes it un-selectable by the PLC. Not Selectable by 4. Connect an Ethernet cable between the Metal Detector and the desired network. The “red” cat5 cable in the metal detector is for the PLC connection while the “blue”...
Page 87
PLC COMMUNICATION SETUP 1. In the Controller Organizer window, under I/O Configuration, right click on your controller Ethernet Port LocalENB. Select Properties, select the General Tab, and assign the PLC Ethernet IP Address,(such as 10.10.10.9) 2. In the Controller Organizer window, under I/O Configuration, under your controller, right click on “Ethernet”, select New Module.
Page 88
3. From the Select Module dialog box expand Communications and select “Generic Ethernet- Module”. Press “OK”. 4. On the New Module Properties Page (General tab): a. Assign a unique Name (such as EzMD) b. Assign the Metal Detector IP Address (such as 10.10.10.10). Please note that this must match the address set on the PLC Configuration page of the metal detector.
Page 89
5. From the “Module Properties: LocalENB” select the Connection Tab. a. Set the “Requested Pack Interval” (RPI) to 250 mS. 6. Connect the PLC Ethernet cable to the same network as the metal detector. 7. On the metal detector PLC Configuration screen, verify both the “IModule” and “PLC” status lights are green...
Page 90
PLC PROGRAMMING 1. The PLC communicates with the Metal Detector using two 6-word blocks of memory in the Generic Ethernet Module. Each word is 16 bits. EzMD:O. PLC output EzMD:I. PLC input Data[0] reserved Data[0] metal detector status Data[1] command Data[1] command confirmation Data[2]...
Page 91
4. The following Metal Detector commands are available: ECIMAL OMMAND 0x0001 Set Running Product (for example product 3) MOV 3 to EzMD:O.Data[2] MOV 16#0001 to EzMD:O.Data[1] Reply EzMD:I.Data[0] contains Metal Detector status EzMD:I.Data[1] contains command 16#0001 EzMD:I.Data[5] contains Metal Detector heartbeat see Sample Program ladder diagram rung 6 0x0002 Read Running Product...
Page 92
5. Metal Detector status EzMD:I.Data[0] is updated approximately every second and with every command exchange. See the sample program rung 0. ESCRIPTION ALUE ALUE metal detector fault fault no fault metal detector warning warning no warning metal detector ready ready not ready invalid Ethernet command invalid...
Page 93
SAMPLE PLC PROGRAM The sample program assumes one generic Ethernet IP module named EzMD, one 16-bit DC input module named Local:1, and one 16-bit DC output module named Local:2. Inputs and outputs assigned below. The Ladder diagram, tags, and rung descriptions can be found on the pages that follow. DC Inputs DC Outputs Local:I.Data...
Page 99
To avoid injury or damage to the equipment, all electrical maintenance on the metal detector is to be performed by qualified service technicians authorized by Eriez Manufacturing Company. WARNING – HAZARDOUS VOLTAGE Hazardous voltages are present in this equipment when energized. All power sources must be isolated or disconnected before accessing the inside of the enclosure.
Page 100
CLEANING For proper metal detector operation, the following cleaning requirements must be met: 1. Material must not be allowed to fill the gap between the aperture and the conveyor slider bed. 2. The aperture and conveyor should be free of contamination (especially metal). Additional cleaning may be needed, based on the sanitary requirements/good manufacturing practices of the customer's production environment.
Page 101
Vertical Metal Detector with Valve Addendum ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506–1402 U.S.A. WORLD AUTHORITY IN SEPARATION TECHNOLOGIES...
Page 102
VERTICAL METAL DETECTOR SAFETY CAUTION Tip over hazard. Do not move the equipment without appropriate mechanical assistance. Follow all lifting and installation instructions defined in this manual. The vertical system with reject valves are rated for NEMA 4X. The vertical metal detector comes in three (3) primary configurations as shown below: Ceiling Mount Unit Floor Mount Unit...
Page 103
LIFTING Raise the unit by lifting from the underside of the plate. DO NOT lift from the head. Lifting the unit improperly may damage the unit and void any warranty. Two Lifting Straps Used to Balance Unit Straps Passed Under Plate between Pipe and Valve Bracket...
Page 104
LIFTING Raise the unit by lifting from the underside of the plate. DO NOT lift from the head. Lifting the unit improperly may damage the unit and void any warranty. Two Lifting Straps Used to Balance Unit Straps Passed Under Plate between Pipe and Valve Bracket...
Page 105
LIFTING Raise the unit by lifting from the underside of the plate. DO NOT lift from the head. Lifting the unit improperly may damage the unit and void any warranty. Two Lifting Straps Used to Balance Unit Straps Passed Under Plate between Pipe and Valve Bracket...
Page 106
INSTALLATION MOUNTING Ceiling Mount Use 1/2” diameter bolts to secure the customer-provided vertical mounting apparatus to the metal detector plate. Ensure four (4) included shoulder washers are in place at each mounting point when mounting. Shoulder washers required for proper installation and operation...
Page 107
INSTALLATION MOUNTING Floor Mount Secure all four (4) feet to the floor using 9/16” bolts. Do not operate equipment unless ALL FOUR feet are secured. Mounting holes provided on each foot...
Page 108
INSTALLATION MOUNTING Wall Mount Secure wall bracket to a stable wall using four (4) 5/8” bolts. All four mounting bolts must be installed before operating the metal detector.
Page 109
INSTALLATION AIR SUPPLY The reject mechanism is operated by an air supply. The connection Adjustment for air is located externally on the right hand side of the unit. A Dial quick release coupling is provided for connecting an air pipe of 1/4 NPT threads to the unit.
Page 110
MAINTENANCE CAUTION Moving parts can crush or cut. Lock out power and air supply before servicing. FREQUENCY Rubber Flapper The reject valve should be inspected every 10,000 Mounting Screws rejects or monthly. NOTE: The flapper seals are replaceable, while the flapper plates are not. Flapper Plate Should the flapper plates wear, the valve body...
Page 111
Vertical Actuator Shock – 4”, 6”, 8” Systems CAUTION Moving parts can crush or cut. Lock out power and air supply before servicing. Introduction The vertical metal detector system now ships with an actuator shock that reduces the amount of vibration generated when the reject valve cycles after detecting metal.
Page 112
Vertical Actuator Shock – 4”, 6”, 8” Systems Removing the set screw on 4”, 6”, and 8” units If it’s desired to install the shock please follow the instructions below for the removal of the set screw and the installation of the shock into the actuator: 1.
Page 113
Vertical Actuator Shock – 4”, 6”, 8” Systems Installing Shock on 4”, 6”, and 8” units If it’s desired to install the shock please follow the instructions below for it’s installation into the actuator: 1. Install O-Ring, sealing washer, and nut onto shock.. 2.
Page 114
Vertical Actuator Shock – 4”, 6”, 8” Systems Adjusting shock on 4”, 6”, and 8” units 1. Note the position of the reject door and the door seal 2. As the shock is screwed into the actuator the door will raise up. 3.
Page 115
Vertical Actuator Shock – 4”, 6”, 8” Systems Adjusting reject shock on 4”, 6”, and 8” units (Cont’d) 5. Once the door position is set push the O-ring against the actuator. 6. Push the sealing washer against the actuator. 7. Tighten the shock nut while holding the shock in position with an Allen wrench 8.
Page 116
Vertical Actuator Shocks - 10” System Introduction: 1. The 10” vertical system uses two actuators one on each side of the valve. 2. Each actuator uses two shocks, one for the reject and one for the return. 3. The reject shocks are next to the quick exhausts. 4.
Page 117
Vertical Actuator Shocks - 10” System Removing and Replacing Shocks If it’s desired to replace the actuator shocks please follow the instructions to remove the existing shocks: 1. Remove air pressure from system. 2. Remove shocks from actuator. 3. Remove the nut, sealing washer and O-ring from each shock removed. Shock Sealing Washer...
Page 118
Vertical Actuator Shocks - 10” System Replacing reject shocks (Cont’d) 1. Install the O-ring, sealing washer and nut onto the shock. 2. Screw the shock about an inch into the actuator, keep the hardware loose 3. Start with one of the two reject shocks. 4.
Page 119
Vertical Actuator Shocks - 10” System Adjusting reject shock on 10” units 1. Note the position of the reject door and the door seal 2. As the shock is screwed into the actuator the door will raise up. 3. With the air off, push down on the door so the shock is compressed while adjusting the shock position.
Page 120
Vertical Actuator Shocks - 10” System Adjusting return shock on 10” units (Cont’d) 1. Push the door to the return position. 2. Adjust the door so the return door seal is just under the valve top. 3. Start with one of the two return shocks 4.
Page 121
Vertical Actuator Shocks - 10” System Testing shocks on 10” units (Cont’d) 1. Insure all four shocks are set and secure. 2. Apply air pressure to the system, the air pressure should be set between 70 and 80 PSI. 3. When air is supplied the door should move to the good product position. 4.