NATURAL GAS CONVERSION
WARNING
1
Conversions only to be done by an
Authorized person
2
A restraining tether or bracket is required to be fixed
to the appliance and to the wall within 50mm of each
connection point. The length of the tether shall not
exceed 80% of the length of the natural gas hose
assembly.
TOOLS REQUIRED
1
Socket head screw driver (Included with the product)
2
Wrench
GAS PIPING
1 A minimum pipe with diameter 15mm is required for
inlet piping. A lever operated shut-off valve should be
installed within 1 meter of the appliance for servicing the
appliance.
2 Where it is not practical to install solid copper pipe to
AS/NZS 5601.1, hose assemblies certified to AS/NZS 1869
or limited flexibility connectors certified to AS 4631 may
be used.
The internal diameter of the hose must not be less than
10mm. The hose should be as short as practicable in
accordance with AS/NZS 5601.
3 All gas pipe connections must be sealed with a gas pipe
compound resistant to natural gas. Remove LPG
hose and regulator and ensure the Natural Gas regulator
supplied with the appliance is used.
NOTE TO INSTALLERS
For main burner, the U-LPG jet is 0.98mm, the NG jet is
1.50mm
For back burner, the U-LPG jet is 0.98mm, the NG jet is
1.65mm
Both U-LPG injector and NG injector are installed together
like right photo shows. The BBQ is set for U-LPG by
manufacturer.
JET FOR NG
Jet for LPG
USER MANUAL
1
Test operation of appliance such as leak-tightness,
burner flames at high and low, and instruct user on safe
operation before leaving.
2
If the appliance cannot be adjusted to perform correctly
contact your
distributor or the manufacturer for assistance.
INSTRUCTIONS FOR CONVERTING THE MAIN BURNER
1.
Unscrew and remove the rear panel pictured.
2.
Unscrew the main burner securing screws
and remove the burner, sitting it alongside.
(1)
(2)