Ger Detect TITAN GER-400 User Manual

Ger Detect TITAN GER-400 User Manual

Gold and metal
Hide thumbs Also See for TITAN GER-400:

Advertisement

Quick Links

English User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TITAN GER-400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ger Detect TITAN GER-400

  • Page 1 English User Manual...
  • Page 2 English User Manual TITAN GER 4 System 1 Device MagnetoMeter System Long Range System Ionic Search System 3D Imaging System...
  • Page 3 English User Manual Critical Warning    Please be sure that all precautions taken against risks Overview Do not use your device while it is raining or on extremely wet floor  Dear customer, thank you for Turn on your device after you make choosing the TITAN GER –...
  • Page 4 English User Manual The Long Range System Recipient Antenna Signal Recipient Signal Transmitter Dispatcher Antenna Figer (1) the long range system components This system specializes to cover vast areas and locate the target with in 1 meter Square up to depths of 45 meters below the surface of the ground and Front Range up to 2,500 meters.
  • Page 5 English User Manual Connect the Signal Transmitter Figer (3) : Signal Transmitter Connect the Signal Recipient Figer (4) : Signal Recipient Connect the Recipient Antenna Figer (4) : Recipient Antenna...
  • Page 6 English User Manual - Connect the Battery to the Device - Open the Device Screen and Start The Device Through ON / OFF switch Figer (5) : Battery & ON / OFF switch CLICK ON THE SCREEN OF THE DEVICE TO DISPLAY THE LANGUAGES LIST THE DEVICE WORKS ON FOUR LANGUAGES: (DUTCH-ENGLISH-FRENCH-ARABIC ) Figer (6) : languages list...
  • Page 7 English User Manual After selecting the language, you want to work in (English for example) The search systems menu will appear (Select long-range search system ) Figer (7) : search systems menu After selecting the long-range system, the metals that this system can detect will appear : Choose the metal to be search for from a list of metals through pressure on the metal name,...
  • Page 8 English User Manual Figer (9) : Front Range Options After selecting the Front Range, the search screen will appear which contain an indicator, which will guide you directly to the target. Make sure that the antenna is pointing ahead Adjust the antenna with the indicator on the screen to receive accurate signal search screen Figer (10) :...
  • Page 9 English User Manual Increasing the length of the antennas Figer (11) : Star the search by holding the device as follow: If the target on the right side the indicator Will Point to the right side and the seam to the left side as follow indicator in right side indicator in left side Figer (12) :...
  • Page 10 English User Manual To determine the depth of the discovered target Stand above target and turn 45 degrees Walk straight ahead until the antenna reverse to the back Figer (13) : determine the depth Measure the distance between the antennas reversing back and the target center point.
  • Page 11 English User Manual The Ionic Search System Recipient Antenna Dispatcher Antenna This system specializes to cover vast areas and locate the target with meter Square up to a depths of meters below the surface of The ground and Front Range up to 2500 meters vertical Connect component...
  • Page 12 English User Manual Connect the Ionic Sensor Figer (15) Dispatcher Antenna - Connect the Battery to the Device - Open the Device Screen and Start the Device through ON / OFF switch Figer (16) Battery & ON / OFF switch Click on the screen of the device to display the languages list the device works on four languages: (DUTCH-ENGLISH-FRENCH-ARABIC)
  • Page 13 English User Manual Figer (17) languages list After selecting the language, you want to work in (English for example) The search systems menu will appear, Select IONIC search system Figer (18) search systems menu After selecting the ionic system, the search screen will appear. Point the device to the ground if the device start to make a sound you must calibrate The device with the ground by pressing on the...
  • Page 14 English User Manual Figer (18) calibration button After you finish the calibration, start the search by moving the device 180 degrees right and left. When the device detect a target, it will start to make a sound. In addition, the indicter will start to move to alert you about the target discovered.
  • Page 15 English User Manual Figer (20) use ionic during driving In the event of lack of vision, you can operate the laser to locate the target place. Through the laser ON OFF, button Figer (21) operating laser...
  • Page 16 English User Manual After detecting the target, confirm the target from four direction North to South South to North East to West West to East...
  • Page 17 English User Manual 3D Imaging System Tablet 3D Sensor Dispatcher Antenna Tablet Holder Figer (21) 3D Imaging System cpmponents This system specializes to show you the area scanned on the tablet screen in three-dimensional photo and through which you can specify the target size, shape and depth of the target underground up to 45 meters.
  • Page 18 English User Manual Connect the 3D Imaging Sensor Figer (23) Imaging Sensor Install the Tablet Holder To The Device Figer (24) Tablet Holder Fix the tablet that supplied with the device on the tablet holder which Contains analysis program to display the photo Figer (25) Fixing the tablet...
  • Page 19 English User Manual - Turning to the tablet to make a Bluetooth connection between the device and the analysis program. Click on the Desktop option Figer (26) Turning tablet on The desktop screen will appear. 1- Touch the arrow to revel the hidden icons. 2- Click on the Bluetooth icon.
  • Page 20 English User Manual Figer (27) tablet desktop screen The tablet will start to search for any devices with Bluetooth in the area. When the device Bluetooth appear click on pair. Figer (28) search for devices...
  • Page 21 English User Manual NOTE: The Bluetooth password is 1000 select the 3D IMAGING system from the systems menu in the device. Figer (29) systems menu After selecting the 3D imaging system, the search screen will appear. Figer (30) search screen...
  • Page 22 English User Manual Open the 3D GER Analyzer that installed on the tablet Figer (31) Openning the 3D GER Start a new project to scan the ground by clicking on new scan Figer (32) Start new scan...
  • Page 23 English User Manual The connection settings window will appear on the screen. Figer (33) connection settings Enter the settings as follow 1- CHOSE DEVICE : TITAN GER 2- INTER FACE : OPEN THE BLUETOOTH SETTINGS AND ENTER THE COM NUMBER ( OUT GOING ) FOR EXAMBLE COM 17...
  • Page 24 English User Manual Figer (34) connection settings 3- TRANSMISSION METHOD : BLUETOOTH 4- OPERATING MODE : GROUND SCAN 5- IMPULSES PER LINE : 10 TO 50 ( EACH IMPULSE = 30 CM ) 6- NUMBER OF LINES : 1 TO 15 ( EACH IMPULSE = 30 CM ) 7- SCAN DIRECTION : OPTIONAL...
  • Page 25 English User Manual After you enter the sittings, click on connect and shift to the device. Therefore, the device will start taking pictures as follow:...
  • Page 26 English User Manual Figer (35) startting taking pictures Explaining Start new scan and disconnect after scanning finish Open file from your tablet already existing in your tablet Cancel the scanning or delete the photo Save the photo as a .GER file to re-open it any time you want Save as a photo with no option to change anything in the photo shape Print report allowed you to see the where about of the metal and the other elements To return the photo as it is was before you start analyzing...
  • Page 27 English User Manual Miniature to make the picture smaller A Tool you use it in case of not clear target to see the correct shape ( - ) A Tool you use it in case of not clear target to see the correct shape ( + ) to make the target in high size to make the target in low size move between the grid squares to pin point the area that you want to know its depth...
  • Page 28 English User Manual Figer: press save after you choice type If you want to have printed report you can press on the print icon, the report will appear, and you can print it (the number in the report it is the value of the ground – metals – cavities...
  • Page 29 English User Manual The Magnetometer System Magnetometer Sensor Figer (36) magnetometer system components Connect component Connect the Sensor to the Device Figer (37) Connecting Sensor...
  • Page 30 English User Manual Click on the screen of the device to display the languages list The device works on four languages: (DUTCH-ENGLISH-FRENCH-ARABIC) Figer (39) languages list After selecting the language, you want to work in (English for example) The search systems menu will appear Select MAGNETOMETER search system...
  • Page 31 English User Manual After selecting the magnetometer system, the search screen will appear. Point the device to the ground if the device start to make a sound you must calibrate The device with the ground by pressing on the calibration button follow: Figer (40) calibration button After you finish the calibration, start the search by moving the device...
  • Page 32 English User Manual When the device detect a target, it will start to make a sound. In addition, the indicter will start to move to alert you about the target discovered. Figer (42) indicter movement The sound will start Accelerating when you will be close to the target. Thanks for choosing our We wish you the best of products...
  • Page 33 English User Manual Warning If you want the device work well without errors you have to follow next steps When using the device please do not wear the watch When using the device please do not wear the jewelry When using the device please get away from metal, lighter and mobile phone Please take off the belt The shoes shoud not contain any metal Stay away from the car...

Table of Contents