  • Page 1 SureFlow compact range: 1000-C & 1000-M Auto-Fill Catering Water Boiler Installation And User Instructions The Professional’s Choice...
  • Page 2: Table Of Contents

    Your new water boiler is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed. All new series Instanta products are energy efficient, simple to operate and easy to service. Find out more about Instanta products at...
  • Page 3: Safety & Environmental Information & Delivery Check-List

    Safety Information Environmental Information Please read the following carefully (Information on disposal for users of waste before switching on this appliance. electrical & electronic equipment). A competent person should install this appliance in The “crossed out wheelie bin” symbol on this product accordance with the installation instructions for this means that discarded electrical and electronic appliance and all relevant local and national standards...
  • Page 4: Technical Specification

    • Once primed with water, the RED LIGHT will We regret that Instanta cannot be held responsible illuminate to show that it is heating. for any machine malfunctions if the water pressure •...
  • Page 5: Regular Daily Use

    Maintenance IMPORTANT NOTE: In normal daily use, the boiler may be used as soon as the GREEN LIGHT shows, & Service Information but on first install, wait 15 minutes before starting to use. Descaling: Regular Daily Use The boiler should be periodically checked for scale build-up…see below: •...
  • Page 6: Service Warnings & Fault Diagnostics

    Red: has activated Controls below using the boiler again. • An internal • Contact component has Instanta • Replace evaporation plates, tank-lid failed Technical and outer lid. Support. • Top probe not Draw-off Tap: recognised.
  • Page 7: Service Technical Support

    Our guarantee includes on site labour and parts Earlier Models: The over-boil cut-out will require a for problems caused by fault of manufacture and manual reset. Contact Instanta Technical Support component failure with the following exclusions: department for assistance with this.
  • Page 8 INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel: (01704) 501114 Fax: (01704) 501115 IB33 - ISS: 03 FM 36413 EMS 75807...