Use Method; Current Data - Hyundai CIT-3500 User Manual

Common rail injector tester, a, u, d, j, s, r engine & u-ii, a-ii, digital controller

Advertisement

2-4 HOW TO USE CRDI HP DIGITAL CONTROLLER.

◎ USE METHOD

1. Connect the Controller Data link cable(DLC) to the Rail Pressure Sensor(RPS), Pressure Regulator Valve(PRV)
2. Connect the Battery Power on the Controller.
3. Select Mode then, Crank In.
※ Warning : Electrode should be connected correctly. Reverse connection can cause electric trouble.
◎ MODE USAGE
1
. Selection : Press the TEST MODE Key.
( OFF → LOW → HIGH → MAX-HIGH → HIGH → LOW → OFF )
2. Explanation
1) OFF : Controller Run status after Power On.
- Power off status in the Pressure Regulating Valve.
2) LOW : Set the pressure by 250 ~ 350bar.
3) HIGH : Set the pressure by 800~1000bar.
4) MAX-HIGH : Set the pressure over 1000bar.
- Particulars adjustment : Press the UP/DOWN button by click.
- Fast Adjustment : Press the UP/DOWN button continuously.

3. CURRENT DATA

- Monitoring Crank-In pressure by the power on status of Pressure Regulating Valve.
- CURRENT DATA (Use only for the high pressure pump test)
- Run the current data mode without press any other key when start the high pressure pump test.
※Note :
Do not press CURRENT DATA key during the Injection test, It prevented the operation
during the test mode.
- DATA HOLD FUNCTION : Press the "UP" button in the CURRENT DATA Mode.
(Release : Press any other button in the Data Hold status)
※ Do not use more 5 minute in the Current mode, otherwise PRV can be damaged by high temperature.