Download Print this page

PCB Piezotronics EX682M71 Operating Manual

Differential din rail charge amplifier

Advertisement

Quick Links

Model EX682M71
DIFFERENTIAL DIN RAIL CHARGE AMPLIFIER
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-828-8840
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: info@pcb.com
Web: www.pcb.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the EX682M71 and is the answer not in the manual?

Questions and answers

Summary of Contents for PCB Piezotronics EX682M71

  • Page 1 Model EX682M71 DIFFERENTIAL DIN RAIL CHARGE AMPLIFIER Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
  • Page 2 Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
  • Page 3 50% of the general contact numbers are: replacement cost returned item(s). PCB will provide a price PCB Piezotronics, Inc. quotation replacement 3425 Walden Ave. recommendation for any item whose Depew, NY14043 USA repair costs would exceed 50% of...
  • Page 4 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 汞 镉 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 铅 (Pb) (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 5 Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 6 Model EX682 Series Differential Charge Amplifier Operating Guide with Enclosed Warranty Information 3425 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 55855 MANUAL REVISION: ECN NUMBER: 47061...
  • Page 7: Table Of Contents

    Table of Contents Introduction ........................Page 3 General Features Installation and Wiring ....................Page 3-5 ESD Sensitivity ........................ Page 6 Warranty/Servicing Warranty, Service & Return Procedure ................Page 7 Customer Service ......................Page 8 PAGE 2...
  • Page 8: Introduction

    Introduction The EX682 Series of differential charge input amplifiers are designed to interface with differential output charge sensors. The unit will convert the charge signal from any differential output charge sensor into a voltage output. The front end differential charge amplifiers are designed to handle low sensor resistance that is common at very ®...
  • Page 9 Connector and Pinout Diagram The EX682 Series use plug-in type screw terminal connectors for all input and output connections. Strip off ~8mm of insulation from the connection wire ends. Using a small screwdriver, remove the terminal block from the enclosure in either the up or down direction, terminate the wire in the correct location. Do not exceed a torque of 0.5Nm.
  • Page 10: Esd Sensitivity

    Warning 2 – ESD sensitivity This equipment is designed with user safety in mind; however, the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. Caution 1 – ESD sensitivity...
  • Page 11 Cables can kill your equipment. High voltage electrostatic discharge (ESD) can damage electrical devices. Similar to a capacitor, a cable can hold a charge caused by triboelectric transfer, such as that which occurs in the following:  Laying on and moving across a rug, ...
  • Page 12: Return Procedure

    Service Because of the sophisticated nature of IMI instrumentation, field repair is typically NOT recommended and may void any warranty. If factory service is required, return the instrumentation according to the “Return Procedure” stated below. A repair and/or replacement quotation will be provided prior to servicing at no charge. Before returning the unit, please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on-site procedures.
  • Page 13: Customer Service

    Customer Service IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may also choose, within the warranty period, to have your purchase price refunded.
  • Page 14 62912 REV. NR ECO 44160 11/24/15...
  • Page 15 62912 REV. NR ECO 44160 11/24/15...
  • Page 16 62912 REV. NR ECO 44160 11/24/15...
  • Page 17 62912 REV. NR ECO 44160 11/24/15...
  • Page 18 62912 REV. NR ECO 44160 11/24/15...
  • Page 19 62912 REV. NR ECO 44160 11/24/15...
  • Page 20 Model Number Revision: NR DIFFERENTIAL DIN RAIL CHARGE AMPLIFIER EX682M71 ECN #: 42321 Performance ENGLISH OPTIONAL VERSIONS Sensitivity(+/-5 %) 5 mV/pC 5 mV/pC Optional versions have identical specifications and accessories as listed for the standard model Input Range +/-250 pC +/-250 pC except where noted below.
  • Page 22 Due to the sophisticated nature of the Charge Amplifiers and associated instrumentation provided by PCB Piezotronics, user servicing or repair is not recommended and, if attempted, may void the factory warranty. However, routine calibration of Charge Amplifiers and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data.
  • Page 23 PCB PIEZOTRONICS INC. 3425 WALDEN AVE. DEPEW, NEW YORK 14043 Installation Overview: The Charge Amplifiers are designed to be mounted on a 35mm Dain rail. Do note install in a harsh area where it can be exposed to cleaning fluid or machine oils. The unit should be mounted in a NEMA type enclosure to protect the electronics from contamination.
  • Page 24 Product : Amplificateur de charge Charge amplifier Type: EX682XYYY 4 Fabricant : Manufacturer : PCB Piezotronics Inc. 5 Adresse : Address : 3425 Walden Avenue Depew, New York 14043 6 Ce produit et ses variantes éventuelles acceptées sont décrits This product any acceptable variation thereto is specified in the dans I'annexe de la présente attestation et dans les...
  • Page 25 U ≤ 28V, I ≤ 100mA, P ≤ 0.7W MARQUAGE MARKING Le marquage du produit doit comprendre : The marking of the product shall include the following : PCB Piezotronics Inc. PCB Piezotronics Inc. Adresse : … Address: ... Type : EX682XYYY Type : EX682XYYY Numéro de fabrication : …...
  • Page 26 ATTESTATION D’EXAMEN DE TYPE - ANNEXE TYPE EXAMINATION CERTIFICATE - SCHEDULE LCIE 13 ATEX 1010 X 1 Version : 01 Issue : 01 17 DETAILS DES MODIFICATIONS DETAILS OF CHANGES Version00 : Evaluation initial Issue 00 : Initial assessment 14/06/2013 2013/06/14 Version 01 : Ajout d’un nouveau modèle (EX682M78).
  • Page 27 Product : Amplificateur de charge Charge amplifier Type: EX682XYYY 4 Fabricant : Manufacturer : PCB Piezotronics Inc. 5 Adresse : Address : 3425 Walden Avenue Depew, New York 14043 6 Ce produit et ses variantes éventuelles acceptées sont décrits This product any acceptable variation thereto is specified in the dans I'annexe de la présente attestation et dans les...
  • Page 28 : 83nF, L : 10mH MARQUAGE MARKING Le marquage du produit doit comprendre : The marking of the product shall include the following : PCB Piezotronics Inc. PCB Piezotronics Inc. Adresse : … Address: … Type : EX682XYYY Type : EX682XYYY N°...
  • Page 29 ATTESTATION D’EXAMEN UE DE TYPE - ANNEXE EU TYPE EXAMINATION CERTIFICATE - SCHEDULE LCIE 13 ATEX 3031 X 1 Version : 01 Issue : 01 16 INFORMATIONS COMPLEMENTAIRES (suite) ADDITIONAL INFORMATIONS (continued) Conditions de certification Conditions of certification Les détenteurs d’attestations d’examen UE de type doivent Holders of EU type examination certificates are also required également satisfaire les exigences de contrôle de production to comply with the production control requirements defined in...
  • Page 30 2016-09-30 DOC # 55886 REV. A ECO # 45736...
  • Page 34 Project: 70086425 Date Issued: 2016-10-27 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, New York 14043 Attention: Carrie Termin The products listed below are eligible to bear the CSA Mark shown Konstantin Rybalko...
  • Page 35 The Model codes suffixes are as follows: X = family type: A – M YYYY = different filtering, gain, frequency response: 0-9999. Class I, Division 2, Groups A, B, C and D: - Model EX682XYYYY Differential Charge Amplifier, input rated 28 Vdc max, 20mA max; non-incendive with entity parameters at Power terminals (VDC, COM): Vmax (Ui) ≤...
  • Page 36 Supplement to Certificate of Compliance Certificate: 2646142 Master Contract: 184981 (103164_0_000) The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 70086425 2016-10-27 Update to report 2646142 to include schematic change. 2646142 2013-11-08 Original Certification of EX682XYYYY...