3M Scotch-Weld PG II LT Owner's Manual

Hot melt applicator

Advertisement

Quick Links

3
Scotch-Weld
Hot Melt Applicator PG II LT Owner's
Manual
Aplicador por fusión al calor de Scotch-Weld
PG II
LT de 3M
Manual del usuario
Manuel de l'utilisateur – Applicateur d'adhésif
thermo-fusible PG II LT 3M
Scotch-Weld
Use only with 3M™ Scotch-Weld™ Hot Melt LM Adhesives
Úselo sólamente con adhesivos de fusión al calor Scotch-Weld™ LM de 3M™
À utiliser uniquement avec les adhésifs thermo-fusibles LM 3M™ Scotch-Weld ™

Advertisement

Table of Contents
loading

Summary of Contents for 3M Scotch-Weld PG II LT

  • Page 1 PG II LT 3M Scotch-Weld ™ ™ Use only with 3M™ Scotch-Weld™ Hot Melt LM Adhesives Úselo sólamente con adhesivos de fusión al calor Scotch-Weld™ LM de 3M™ À utiliser uniquement avec les adhésifs thermo-fusibles LM 3M™ Scotch-Weld ™...
  • Page 2: Table Of Contents

    Preventive Maintenance ..................7 Troubleshooting ....................9 Repair Part Kits ................11 Repair Procedures ..................13 General Assembly (Schematic)..............20 Electrical Control/Wiring Arrangement............21 Flow Control ....................22 Accessories....................23 Repair Service ....................24 Important Notice ...................24 Warranty and Limitation of Remedies............24 Limitation of Liability...................24 3M Sales Branches.................Back Cover...
  • Page 3: Important Safety Instructions

    Important Safety Instructions SAVE THESE INSTRUCTIONS Read instructions thoroughly before operating or performing any maintenance on 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. Caution Danger Contact with molten adhesive or hot applicator tip Do not modify the plug provided with the 3M or metal components may cause burns.
  • Page 4: General Information

    General Information READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING OR PERFORMING ANY MAINTENANCE ON 3M™ SCOTCH-WELD™ HOT MELT APPLICATOR PG II LT. The 3M™ Scotch-Weld™ Hot Melt Applicator PG II When trigger (1) is pulled, the variable regulator (2) LT is designed to be a simple, reliable tool for allows air pressure into rear of the Speedloader stick dispensing 3M™...
  • Page 5: Setup And Installation

    Setup and Installation 1. Remove the 3M™ Danger Scotch-Weld™ Hot Melt Do not modify the plug provided with the 3M Scotch-Weld Hot Melt Applicator PG II LT. Applicator PG II LT from its Improper grounding connection of the plug may shipper and inspect for obvious cause electrical shock.
  • Page 6 The hose portability of the bench stand is desired, simply connection at the end of the 3M™ Scotch-Weld™ attach the stand to a piece of scrap wood Hot Melt Applicator PG II LT air hose is 1/8’’...
  • Page 7: Operation

    Application only. Use of other adhesives may damage the applicator or result in hazardous conditions. Get a feel for your new 3M Scotch-Weld Hot Melt Applicator PG II LT. Start by applying small After warm-up, load applicator with the 3M amounts of adhesive in puddles on a piece of scrap or Scotch-Weld Hot Melt LM Adhesive you’ll be using...
  • Page 8 Applicator PG II LT. Do not tighten the tip. Overtightening could damage the valve assembly. The 3M Scotch-Weld Hot Melt Applicator PG II LT includes a 9921 (.093’’) tip as standard equipment. Other tips, available from your 3M Scotch-Weld Hot Melt Adhesive distributor, are shown on page 22 of this manual.
  • Page 9: Preventive Maintenance

    Operation," page 8), up to one hour heat up prior to use may be required. 2. Make sure that the 3M Scotch-Weld Hot Melt Applicator PG II LT is plugged into 120 VAC and that the switch is in the “on” position.
  • Page 10 Preventive Maintenance During Operation After Operation Before shutting down the 3M Scotch-Weld Hot Melt Applicator PG II LT, put the electrical switch in the “off” position. Continue using the applicator until approximately one adhesive stick has been discharged. Note If proper shutdown procedure has not been followed, up to one hour heat up prior to use may be required.
  • Page 11: Troubleshooting

    Correction (In order of priority) Low or no adhesive flow 1. Hung adhesive stick Turn on the 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT and allow it to heat for at least 60 minutes. Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns.
  • Page 12 Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator.
  • Page 13: Repair Part Kits

    Troubleshooting Repair Parts Kit For ease and convenience in repair, 3M™ Scotch- Part kits can also be ordered directly from the nearest Weld™ Hot Melt Applicator PG II LT repair part kits 3M Sales Branch listed on the back cover.
  • Page 14 Branch location listed on the back cover of this manual. Please note the serial number of your 3M require replacement for optimum performance. We Scotch-Weld Hot Melt Applicator PG II LT before have listed below certain part kits that you may want ordering part kits.
  • Page 15: Repair Procedures

    Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator.
  • Page 16 Contact with molten adhesive or hot applicator tip or applicator is at room temperature before servicing metal components may cause burns. Wear heat- 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. resistant gloves and safety glasses when operating or Failure to disconnect air and electrical power before...
  • Page 17 Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator.
  • Page 18 I. Heater Kit H. Heat Shield Kit Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Caution Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing...
  • Page 19 Place one probe from the meter on the connector of the 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. wire that has been removed, and with the other probe, Failure to disconnect air and electrical power before...
  • Page 20 Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. The thermal cutout assembly is then removed by Failure to disconnect air and electrical power before...
  • Page 21 Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M™ Scotch-Weld™ Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator.
  • Page 22: General Assembly (Schematic)

    G. 9220 Trigger Kit L. 9226 Dump Valve Kit C. 9223 Valve Kit H. 9932 Heat Shield Kit M. 9935 Speedloader Chamber Assembly D. 9220 Hose Kit I. 9222 Heater Kit E. 9207 Power Cord Kit J. 9931 Thermostat/TCO Kit © 3M 2006...
  • Page 23: Electrical Control/Wiring Arrangement

    General Assembly Electrical Control Wiring System © 3M 2006...
  • Page 24: Flow Control

    9727 Tip rearward, increasing amounts of adhesive are dispensed. Your 3M Scotch-Weld Hot Melt Applicator PG II LT is equipped with a 9921 (.093’’) tip as a standard 9726 “T” tip for RSC carton closing and other uses. equipment. This tip will provide maximum flow for all 9727 “L”...
  • Page 25: Accessories

    Applicator PG II LT A special bench mount assembly is available which allows the 3M Scotch-Weld Hot Melt Applicator PG II LT to be mounted in a 45° position and operated with a foot pedal. It is adjustable to allow positioning of the nozzle tip from a minimum of 9 1/2’’...
  • Page 26: 3M Repair Service

    OF A COURSE OF DEALING, CUSTOM, OR your local 3M Scotch-Weld Hot Melt Adhesives USAGE OF TRADE. This warranty does not distributor or from the nearest 3M Sales Branch listed cover routine maintenance, normal wear and on the back cover.
  • Page 27 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: 9946...

Table of Contents