Asetab-Fail__Osc (Ase Table-Fail (Osc)) - Adva FSP 3000R7 Maintenance And Troubleshooting Manual

Fiber service platform
Hide thumbs Also See for FSP 3000R7:
Table of Contents

Advertisement

Table 136: ASETAB-FAIL__OSC (Standing Condition)
AIDTYPE
Default
Severity
OM:
MN
RAMAN
FSP 3000R7 Maintenance and Troubleshooting Manual - Product Release 16.2 - Document Issue A
ASETAB-FAIL__OSC (ASE Table-Fail
(OSC))
The corresponding SNMP name for this condition is "aseTableGenFailOscMissing".
Probable Cause
The incoming network
side optical fiber does not
contain an Optical
Supervisory Channel
signal which is within the
required optical power
level range.
Suggested Corrective Action
1
Verify that the correct fiber is coupled to the
network side input port of the amplifier module,
and correct any cabling issues if they exist.
2
Verify that the optical signal arriving at the network
port complies with the specified power level range
for the module. Verify that the optical amplifier at
the far-end of the transmission span is in-service
and operating normally, without any active laser
safety condition or shutdown in effect, that the
corresponding OSC facility is provisioned, in-
service and operating without error, and that the
OSC signal is correctly connected to the
transmission line. If the far-end amplifier and OSC
is operating normally and within acceptable output
power levels, but the received power is too low,
this indicates a problem in the transmission space
or that the span exceeds the maximum allowable
length. Address the span loss or length issue as
needed. If the far-end amplifier is not operating
normally and within specified limits, address the
far-end issues first.
3
Inspect the optical connector on the incoming
transmission fiber and the network side receive
port of the amplifier module and clean them if
needed. If the fiber connector on the cable is
damaged, replace the connector or fiber cable, as
appropriate. If the connector on the module is
damaged, replace the module.
4
Perform the ASE table build process on the
amplifier module (e.g. the OPR-ASETBL-OM
command in TL1).
5
Replace the amplifier module.