Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ping and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Komfovent ping

  • Page 1 Installation Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION.........................3 NETWORK MODULE CONNECTIONS .................3 NETWORK MODULE INSTALLATION.................3 EXAMPLES OF NETWORK CONNECTION..............6 IP ADDRESS CHANGING ....................7 MODBUS ADDRESS CHANGING..................10 Network module manual - 2 -...
  • Page 3: Introduction

    Network module “Ping” is intended for connection of KOMFOVENT air handling units to the computer network (Ethernet) or another network (RS-485). If “Ping” module is not added by factory, it can be installed on each air handling unit (AHU) additionally (except units with C2 controller).
  • Page 4 2. After Network module is installed in provided place control panel needed to be disconnected from air handling unit: 3. Disconnected from the panel cable connect to the “Ping” module J1 socket: 4. Connect one end of the cable from installation kit to the panel and another end to J2 socket of “Ping”...
  • Page 5 RS485 serial interface. MODBUS network line is connected to J3 socket of “Ping” module. J3 socket type: : PHOENIX CONTACT - MC 1,5/3-ST-3,5 - PLUG, FREE, 3.5MM, 3WAY): Note: In one serial line of RS-485 network may be connected not more as 30 “Ping” modules. Network module manual...
  • Page 6: Examples Of Network Connection

    EXAMPLES OF NETWORK CONNECTION Picture 1. Connection through “Ethernet” network Picture 2. Connection through RS485 line Network module manual - 6 -...
  • Page 7: Ip Address Changing

    IP ADDRESS CHANGING For working of AHU’s in „Ethernet“ network each „Ping“ module must have different IP address. Default addresses are: IP address – 192.168.0.29 Gateway address – 192.168.0.1 Subnet mask – 255.255.255.0 There is possibility to change these network addresses if standard does not fit by connection through „Ethernet“...
  • Page 8 The green light (5) indicates that connection between computer and network module is enabled. There is possibility to see programmed network addresses by pressing “Read” button (6): Programmed network addresses are displayed in “Static Configuration“ and “Current Configuration“ columns: Network module manual - 8 -...
  • Page 9 For changing network addresses first there is a need to erase current addresses located in “Static Configuration” column. Then, in „Static Configuration“ column, in IP cell should be written a new IP address (213.226.94.133), in “Gate“ cell – new gateway address (213.226.94.1), in “Subnet“...
  • Page 10: Modbus Address Changing

    MODBUS ADDRESS CHANGING If air handling units are connected to serial RS485 line, for each “Ping” module is needed to select MODBUS address for retranslation. For it using one of the above mentioned connections (Ethernet or RS485) in “Ping Manager” program must be inserted retranslating address (11), push the “Write”...