ZIEHL MU2000K Quick Manual

Universal measuring transducer for voltage and current (ac and dc)

Advertisement

Quick Links

Temperature Relays and MINIKA®
Quick Guide MU2000K
- Universal Measuring Transducer for Voltage and Current (AC and DC)
Detailed operating manual see:
https://www.ziehl.com/en/products/?view=detail&detail=110
1 Display and controls
2 Factory setting
Default settings:
Input: AC 5 A (AC 0 – 5 A)
Output: DC 0 – 10 V, 0 – 20 mA
Measuring time: 160 ms (8 measurements, x 20 ms measurement time)
MU2000K
12600-0752-00
Mains Monitoring
Digital Panelmeters MINIPAN®
- Set
Button to navigate in menu
- Down
Button to change Parameters
- LED Power
Device active
- LED I
Current input active
- LED U
Voltage input active
- LED AC
Alternate Current /
Voltage measuring active
Switching Relays and Controls
Page 1 / 8
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2018-02-19 / sm
www.ziehl.de
www.ziehl.de

Advertisement

Table of Contents
loading

Summary of Contents for ZIEHL MU2000K

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection updated: 2018-02-19 / sm...
  • Page 2: Connecting Diagram

    The device has a universal power supply, that is suitable for DC- and AC voltages. Before connecting the device to supply-voltage make sure that the connected voltage corresponds with the voltage on the lateral type on the device. MU2000K 12600-0752-00 Page 2 / 8...
  • Page 3: Installation

     Parameterization „output“ → LED Power flashes 4x • Select with button [Set] the output Number range Of flashes U + I 0 - 10 V / 0 - 20 mA 2 - 10 V / 4 - 20 mA MU2000K 12600-0752-00 Page 3 / 8 www.ziehl.de...
  • Page 4 U (AC / DC) 0 - 10 V / 0 - 20 mA 0 … 5 A 0 … 5 A I (AC / DC) 2 - 10 V / 4 - 20 mA MU2000K 12600-0752-00 Page 4 / 8 www.ziehl.de...
  • Page 5 LEDs (U + I) 1 x flash -> output 0 - 10 V / 0 - 20 mA o LEDs (U + I) 2 x flash -> output 2 - 10 V / 4 - 20 mA • Press button [Down]  End of parameterization, LED ON lights permanently MU2000K 12600-0752-00 Page 5 / 8 www.ziehl.de...
  • Page 6 80 ms (60Hz = 67 ms) 160 ms (60Hz = 133 ms) 320 ms (60Hz = 267 ms) 640 ms (60Hz = 533 ms) • Press button [Down]  End of parameterization, LED ON lights permanently MU2000K 12600-0752-00 Page 6 / 8 www.ziehl.de...
  • Page 7: Error Search

    22mA at output 0/4…20 mA, 11V at output 0/2…10 V (LED Power flashes quickly) Cause Internal error of device Remedy Reset by interrupting supply voltage. If the error cannot be patched by a Reset send back to factory for repair. MU2000K 12600-0752-00 Page 7 / 8 www.ziehl.de...
  • Page 8: Technical Data

    Snap mounting on 35 mm standard rail EN 60 715 or M4 screws Weight app. 100 g Subject to technical changes 9 Housing Type K Dimensions in mm 22,5 110,0 100,5 lower part upper part screw holes for screw-mount MU2000K 12600-0752-00 Page 8 / 8 www.ziehl.de...

Table of Contents