ACTpro 1520e PSU Installation guide
The ACTpro 1520e includes an ACT 12V DC 2A power supply unit.
The 2A output current is used to power the
controller and supply the battery recharge
current. 500mA is reserved for battery recharge
and to power the ACTpro Controller. Therefore
1.5A is available to power readers and the lock.
Example: Power budget of a typical single door
read in/out installation.
Total Current Available
ACTpro Controller and Battery Recharge
ACT Reader X 2
Typical Mag Lock
Total Consumption
Spare Capacity
Note: See section 11 for ACTpro 1520e Installation & Tech nical Specifi cation
Copyright © 2016 Access Control Technology Ltd. Part No. 18-00099 Issue 1.0
3
2000mA
500mA
200mA
800mA
1500mA
500mA