7
Loopback Test
You can perform a loopback test by connecting either
an RS-232 to RS-422/485 converter or a USB to RS-
422/485 converter to the 4WSD9R(4WSD9TB).
Using HyperTerminal or a similar program, connect to
the appropriate COM port. Remember to set the baud
rate to 9600. Turn off HyperTerminal local echo. Start
typing. If you can see the data you are typing, the
loopback is successful.
8
Biasing
Bias is provided by 4.7kΩ pull-up/down resistors on
the Data-In lines. This value is adequate for most
applications without termination. If another value is
required, space is provided on the PC for through-hole
resistor placement (R12, R21, R14, and R23).
Document Number: 710-10715-00_r1_4WSD9x_4617qsg
Recommended Accessories
12VDC, 6W Power Supply, 2.5mm Plug,
International AC Input
# SMi6-12-P230-C1
DB9 Male to DB9 Female Cable,
1.8 m (6 ft) length
# 9PAMF6
1-888-948-2248 | Europe: +353 91 792444
advantech-bb.com
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: 815-433-5100 | Fax: 815-433-5109
www.advantech-bb.com | E-mail: support@advantech-bb.com
QUICK START
GUIDE
Models 4WSD9R, 4WSD9TB
Port-Powered RS-232 to RS-485 Converter
Before you begin, be
sure you have the following:
+ RS-232/485 Isolated Converter
(#4WSD9R or #4WSD9TB)
+ DB9 to DB9 Adapter Cable (not included)
+ 12VDC, 6W Power Supply (not included)
www.advantech-bb.com
Fast and easy on the web:
Need help?
Do you have a question about the 4WSD9R and is the answer not in the manual?