now ready to begin watering automatically.
(See Figure 10)
When watering begins, MINS TO RUN will alternate with the
current time and day to indicate the time left on current
cycle.
In this mode, the unit executes any programmed schedule or
default schedule.
NOTE: The normal operating condition is for the
alve to open
V
20 seconds after the programmed start time.
Figure 10
In this mode, extra (Manual) watering is ceased.
In this mode, Delay mode is canceled.
Note: When no button has been pressed for 1 minute, the timer
will automatically switch to the AUTO mode and all the pro-
grammed settings. You may push MODE button to return to
Mode Selecting. Push MODE button to select SET. The word
SET will blink to indicate that it is selected.
MANUAL (EXTRA) WATERING
The Orbit timer allows you to add an extra 1 to 99 minutes of water-
ing time for one or all stations. The manual setting does not alter
the automatic settings during or after manual use.
Push MODE button to select MANUAL. The word MANUAL
will blink to indicate that it is selected.
Push CONFIRM button to begin the manual mode. STATION
(STN) 1 will flash.
To have all stations water in manual (extra) mode, push
CONFIRM button and all the stations will water at the dura-
tion previously set.
NOTE: The normal operating condition is for the
alve to open
V
2 minutes after the CONFIRM button is pushed.
To have only one station water in manual (extra) mode, push
+ or – to select which station to water.
Push CONFIRM button to confirm the selected station to
water. MINS TO RUN will show with two digits or "- -" flash-
ing. (See Figure 11)
Figure 11
Push + or – button to set the duration for the extra watering.
Push CONFIRM button to confirm the desired duration. The
extra watering will begin immediately for the duration select-
ed at the selected station.
As watering begins, MINS TO RUN will alternate with the
current time and day to indicate the time left on manual
cycle. The station currently being watered will also show.
To discontinue the manual watering mode, push + and –
together, and extra watering will end immediately.
When the extra watering is finished, the unit will resume auto
mode.
DELAY WATERING
The Orbit timer allows you to delay automatic watering for 1-24 hours.
Push MODE button to select DELAY. The word DELAY will
blink to indicate that it is selected. The unit will initiate a 24
hour delay.
Push CONFIRM button to begin delay mode. "24 Hr" will blink
and the word DELAY will appear.
(See Figure 12)
Figure 12
Push + or – button to change the hour delay within 10 sec-
onds after pushing CONFIRM button to begin delay mode.
Otherwise, "24 Hr" and the current day and time will alternate-
ly blink and the timer will not accept a delay hour change. If
this occurs, repeat the previous three instructions.
Push CONFIRM button to confirm the delay mode for the
desired time.
LEFT will appear to indicate the time remaining on delay.
To discontinue delay watering, push MODE button.
OFF MODE
In Off Mode all watering programs are inactive and no watering will
occur.
Push MODE button to select OFF. The word OFF will blink to
indicate that it is selected. (See Figure 13)
Figure 13
Push CONFIRM button to begin off mode.
While in off mode, the unit will continue to display current
time and day.
To discontinue off mode, push + and – buttons together. The
unit will resume auto mode.
OFF-SEASON STORAGE & MAINTENANCE
Turn the water off at the hose faucet and leave brass manifold
outlet control levers in the "on " position for each connected
valve.
Push MODE button to select MANUAL. The words MANUAL
and SET will blink to indicate that they are selected.
Push CONFIRM button to begin the manual mode. STATION
(STN) 1 will appear, indicating the current station
Push + or – button to advance to the valve station matching
the connection to the timer.
Note: STNs 1-4 match the connector ports underneath the timer
from furthest left to furthest right.
Push CONFIRM button to control running time. MINS TO RUN
will show with two digits or "- -" flashing.
Push + or – button to set the duration for 1 minute.
Push CONFIRM button to open valve, draining water and
relieving pressure. Repeat the previous six steps, if neces-
sary, for other valve connections with the timer.
Move the individual brass manifold outlet control levers to the
"off" position.
Remove as many black valve connector plugs as needed from
the ports underneath the timer.
Remove the timer either from the valve or from the wall-
mounted bracket.
Clean and dry the timer, if needed.
Remove the batteries. Clean the contacts in the battery com-
partment. Apply new battery and terminal protection com-
pound. If the batteries show any sign of corrosion, discard
them.
Store timer in a warm and dry place (avoid freezing).
Remove as many water connections as needed from either
the brass manifold outlets or the valve outlets.
Remove as many valves as needed from the 4-outlet brass
manifold.
Remove the 4-outlet brass manifold from the outside hose
faucet.
Place Automatic Yard Watering System components in origi-
nal packaging for off-season storage.
TROUBLESHOOTING
PROBLEM/POSSIBLE CAUSES
Water does not turn on:
1. Programming is incorrect.
2. Batteries are too weak to operate valve.
3. Pressure is in excess of 80 psi.
4. Hose faucet is turned off.
5. Timer is in the off or delay mode.
Timer display is blank:
1. Batteries are dead.
2. Faulty display.
Timer will not operate manually:
1. Water to faucet is turned off.
2. Manifold outlet valve is turned off.
3. Timer is in the off mode.
4. Station selected may not match the port station number
underneath the timer.
MOUNTING BRACKET INSTALLATION INSTRUCTIONS
Layout A
1
2
3
4
Layout B
CAUTION:
I
Use a lead anchor when installing into masonry; use a
plastic anchor when installing into stucco.
I
Brace must be installed to avoid damage to the hose
faucet. Refrain from putting pressure on the manifold by
tugging at the hose.
I
For outdoor use with cold water only.
I
Check local plumbing codes. Codes vary and some may
require use of anti-siphon valves to be installed at the
ends of the manifold.
I
Freezing areas: Disconnect the manifold from the faucet
prior to freezing weather to avoid faucet damage.
PRODUCT INCLUDES
Orbit
®
Irrigation Products, Inc.
North Salt Lake, UT 84054
1-800-488-6156
www.orbitonline.com
© 2008 Orbit Irrigation Products, Inc.
All rights reserved. All trade names are registered
trademarks of respective manufacturers listed.
PN 62032-24E Rev F

Advertisement