Quick Links

automatIc Yard
WaterIng sYstem
InstructIons
Controls up to 4 stations (comes with 2 valves
that control stations, purchase additional
valves separately).
Up to 3 start times per day (cycles A,B,C).
Waters from 1-240 minutes per start time
(per valve).
For outdoor use with cold water only.
Model 56041
Product Includes:
A (1) #14 Round Head Screw
B (1) 7 1/4 in. Support Rod
A
B
www.fluid-studio.net
1065 South 500 West
Bountiful, Utah 84010
1
5
6
2
7
4
9
1 2
1 0
3
8
1 1
1 4
1 3
Watering stations
Clock, start time, and
1
9
Indicates when next
watering duration
2
watering cycle will start
AM or PM for clock
1 0
Manual watering is on
and start time
3
How often timer will
Low battery
4
1 1
water in interval mode
Indicates numbers in clock
1 2
Cycle start times
section as hours, minutes,
5
Timer is in set mode
or days
6
Rain delay is on
Days of the week
7
1 3
Timer is watering
Interval watering mode
8
1 4
1
5
2
3
6
7
4
8
1 Battery tray
2 LCD screen—displays setting and watering program for timer
3 Function dial—turns to set watering program
4 CLEAR button—clears individual settings of program
5 + – buttons—advance or reverse settings
6 < > buttons—move cursor to different settings
7 ENTER/MANUAL button—selects setting or turns on rain
delay when in AUTO
8 RESET—clears all programmed settings
InstallatIon
1. Attach manifold to an outdoor hose faucet.
2. Secure manifold to wall using the mounting hardware and
instructions provided.
3. Attach up to 4 valves to the manifold outlets (the valves are
electronically operated and must be attached to the timer
for proper operation). Open fully each of the shut-offs with
a valve attached.
4. Connect the wire from each valve to one of the numbered ports on
the back of the timer. The numbers 1 through 4 are the "STATIONS"
used while programming your timer.
5. Install two AA alkaline batteries into the battery tray (battery tray
may be removed by pulling out to the left).
Please ensure that the valves are attached to the timer before installing
batteries. Once the batteries are installed the timer will immediately begin
a start-up sequence. A countdown from 150 down to 0 will begin on the
display and will take a few minutes. Your timer can be programmed during
the countdown, but the valves cannot be actuated until it is completed.
6. Create your timer program.
7. Slide timer onto a valve mounting bracket.
8. Turn on hose faucet.
1
dimensions:
proof no:
flat: w: 12" h: 9"
date:
01.11.13
finished: w 3.0" d: " h 3.0"
colors
des:
SH
client:
Orbit
sku:
56041
p 801 295 9820
upc:
NA
f 801 951 5815
additional instructions:
file name:
·
56041-24 rB.indd
· Proofing Code:
·
software:
InDesign CS5
Mounting the Manifold to the Wall
3
1
2
1. Attach support rod to manifold by inserting it into the two mounting
holes on the back of the manifold.
2. Mark where support rod touches the wall.
3. Drill a pilot hole using a 1/4 in. drill bit.
4. Attach the support rod using the screw provided.
Installing The Batteries
1. Remove the tray on the side of the timer by sliding it out.
2. Insert two AA (1.5V) alkaline batteries (not included) and replace the tray.
Low battery icon will appear when batteries need replacing. Replace
batteries within 30 seconds or timer programming will be lost.
Tip: Remove batteries when timer is not in use for extended periods.
ProgrammIng
Rotate the dial to positions indicated for setup.
1. Turn Dial to Set Clock
1. Press the + button to advance clock time (hold button for quick
advance). Press the – button to reverse clock time (hold button for quick
advance). *Keep in mind am/pm.
2. Press ENTER or turn the knob to accept clock time.
2. Turn Dial to Set Day
1. Use the < and > buttons to move cursor (blinking line)
over current day.
2. Press ENTER or turn dial to accept the day.
3. Turn Dial to Start Time
Each start time cycles through all watering stations (1, 2, 3, and 4). Cycle A
is for if you want to water once a day. Add Cycle B if you want to water two
times a day (2 different start times). Add Cycle C if you want to water three
times a day (3 different start times).
1. Use < and > buttons to select start time A, B, or C.
2. Press ENTER to edit start time.
3. Use the + and – buttons to set desired start time.
* Keep in mind am/pm.
4. Press ENTER to accept the setting.
5. Repeat steps 1 through 4 for B and C if you want to water more than
once a day.
To clear a start time:
1. Use the < and > buttons to move the cursor over cycle letter (A, B, C).
2. Press ENTER to select.
3. Press CLEAR.
EXAMPLE: If cycle A is set for 6:00 am, then at 6:00 am your first valve will
turn on and run for its duration, then it will turn off and the second station
will automatically turn on and run for its duration.
4. Turn Dial to Run Time
Set watering duration from 1 to 240 minutes for up to 4 stations.
1. Use the < and > buttons to select the run time for valves stations
1, 2, 3, or 4.
2. Press ENTER after each selected Station. [ ] will appear around the
Stations selected to water.
3. Press CLEAR to deselect a Station.
Or
1. Use the + and – buttons to increase or decrease the number of
minutes to water.
2. Press ENTER to accept the setting.
3. Repeat steps 1 and 2 for each station you would like to water.
color
color
Registration
non printing
non printing
PMS
PMS
K
????
????
Font sizes cannot be smaller than 7 pt.
5. Turn Dial to How Often
Select which days to water or every 1 to 14 days. All stations and cycles
4
will water on selected days.
1. Use the < and > buttons to select which days to water Sunday
through Saturday.
2. Press ENTER after each selected day. [_] will appear around days
selected to water.
3. Press CLEAR to deselect a day.
Or select INTERVAL. 1 is every day, 2 is every other day etc. up to 14 days.
1. Use the + and – buttons to increase and decrease the number of days.
2. Press ENTER to accept the setting.
6. Turn Dial to Auto
Timer waters according to programmed start time(s), run time(s), on the
programmed days or interval; this is where you want the dial to have your
program run.
Manual Watering
Allows you to water immediately without interrupting
the set cycle(s).
1. Press the MANUAL button when dial is turned to AUTO
2. Press ENTER to run all stations once as previously
programmed in RUN TIME section. Or, use the < and >
buttons to select which station(s) to manually water.
3. Press ENTER when cursor is over desired watering station.
4. Use + and – buttons to set from 1 to 240 minutes
* There will be a 6 second delay till your cycle will begin
Screen will flash between clock and minutes remaining
on cycle. To remove manual watering and resume
programmed cycle press CLEAR.
Rain Delay
Delay watering cycle during precipitation to conserve water.
1. When in AUTO, press + button for 24 hrs, 48 hrs, or 72 hrs.
Screen will flash between clock and hours remaining before programmed
cycle resumes. To remove rain delay, press CLEAR, or turn dial to OFF and
then back to AUTO.
Off
Off stops the timer from watering and clears Rain Delay.
troubleshootIng
Water does not come on at desired time. Check if:
Clock is set to correct time including AM and PM.
Start time is set to desired time including AM and PM.
Start times begin after previous watering cycle has run
through all stations and set durations.
Rain Delay is on (DELAY appears on left side of screen if on).
Timer does not water. Check if:
Shut-off on the valve outlets are open.
Timer is set to AUTO.
Batteries are low.
Clock is set to correct time including AM and PM.
Rain Delay is on (DELAY appears on left side of screen if on).
Valve plugs are inserted in the correct corresponding timer outlet.
Water won't turn off. Check if:
Watering duration is set to desired time.
Start times begin after previous watering cycle has run
through all stations and set duration.
Working Water Pressure
Minimum: 25 psi Maximum: 100 psi
Working Temperature
Maximum: Do not exceed 120° F
Minimum: Keep from freezing
Warnings:
For outdoor use with cold water only.
Printers are responsible for
meeting print production
requirements. Any changes
must be approved by the
client and Fluid Studio.
printed piece must meet
designated specifications
on this form.
PMS
????
© 2012 Fluid Studio. This
work is the property of Fluid
Studio, and cannot be used,
reproduced or distributed
in any way without their
express permission.

Advertisement

loading

Summary of Contents for Orbit 56041

  • Page 1 Timer is in set mode or days 1. Press the MANUAL button when dial is turned to AUTO ProgrammIng Model 56041 Rain delay is on Days of the week 2. Press ENTER to run all stations once as previously Timer is watering Interval watering mode Rotate the dial to positions indicated for setup.
  • Page 2 B si desea regar dos veces al día (2 horas de inicio diferentes). postergación por lluvia cuando está en AUTO presione CLEAR. Añada el ciclo C si desea regar tres veces al día (3 horas de inicio Modelo 56041 8 RESET—borra todas las configuraciones programadas Postergación por lluvia diferentes).