Advertisement

58CVA/CVX
INFINITYt 80 VARIABLE SPEED
4-WAY MULTIPOISE FURNACE
Input Capacities: 70,000 thru 155,000 Btuh
Product Data
THE INFINITY
The Infinityt 80 Variable- -Speed, 4-way Multipoise Gas Furnaces
offer
IdealHumidityt technologies in an 80% AFUE gas furnace. You
get all the benefits of a ComfortHeat technology furnace: reduced
drafts, reduced sound levels, longer cycles, less temperature swings
between cycles, and less temperature differences between rooms.
With the variable speed blower motor, homeowners can now
economically run constant fan to help eliminate temperature
differences throughout the house and to get better indoor air
quality. This furnace with IdealHumidityt technology also
increases comfort in the summer by wringing out extra humidity
when needed. The Infinity 80 furnaces are approved for use with
natural or propane gas, and the 58CVX is also approved for use in
Low NOx Air Quality Management Districts.
Carrier Infinityt System When the Infinity 80 variable- -speed
gas furnace is matched with the Infinity Control and an air
conditioner or heat pump, you will experience the ultimate in
I
NFINITY
IdealHumidity
ComfortHeat and IdealHumidity through unparalleled control of
temperature, humidity, indoor air quality, and zoning. The Carrier
Infinity System also provides unprecedented ease of use through
on- -screen,
malfunction alerts. For even greater comfort and convenience,
match the Infinity 80 furnace with an Infinity air conditioner or
heat pump. This will create a fully communicating system,
requiring only 4 thermostat wires between system components, and
troubleshooting can even be done in the future from the outdoor
unit without entering the home.
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.
STANDARD FEATURES
S Infinity System- -match with the Infinity Control for Infinity
A04042
S ComfortHeat Technology Intelligent microprocessor control
S Two- -stage heating with single- -stage thermostat with patented
S Very low operating sound through low-stage operation and
S Integral part of the IdealHumidity System
S Variable-speed ECM blower motor
80 GAS FURNACE
t
unmatched
comfort
text- -based
service
System benefits
Adaptive Control Technology
QuieTecht system
Maximum dehumidification selection for summer time cooling
Full IdealHumidity benefits including "Super Dehumidify"
SmartEvapt- -Humidity control when using a
Thermidistatt/Infinity control
Increased SEER ratings for AC and HP systems as compared to
the Air Conditioning Heating and Refrigeration Institute's
standard coil- -only rating when paired with selected Carrier
with
ComfortHeatt
and
reminders
and
equipment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 58CVX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 58CVX

  • Page 1 The Infinity 80 furnaces are approved for use with natural or propane gas, and the 58CVX is also approved for use in Low NOx Air Quality Management Districts.
  • Page 2: Model Number Nomenclature

    CONTROL BOARD INDUCER BLOWER MODEL NUMBER NOMENCLATURE 58CVA 58CVA Variable Speed 4-Way Multipoise Nominal Cooling Size 58CVX Low NOx Version (Airflow at .5 ESP .) (400 CFM per 12,000 Btuh) 12--- 1200 CFM 16--- 1600 CFM 20--- 2000 CFM 22--- 2200 CFM...
  • Page 3: Furnace Components

    FURNACE COMPONENTS INDUCER MOTOR ASSEMBLY VENT ELBOW* MAIN LIMIT SWITCH (BEHIND GAS VALVE) PRESSURE SWITCHES DRAFT SAFEGUARD SWITCH FLUE COLLECTOR GAS MANIFOLD GAS VALVE GAS BURNER FLAME SENSOR MANUAL RESET LIMIT SWITCHES BLOWER DOOR SAFETY SWITCH HOT SURFACE IGNITER BLOWER AND MOTOR CONTROL RATING PLATE...
  • Page 4 Saves decorating and cleaning furniture, rugs, and draperies in expenses by keeping carpets, better condition. Moisturizing For the ultimate in home comfort, Carrier’s furniture, and drapes cleaner. 2, 4, and 8-zone systems allow temperature household air also helps to retain control of individual “zones”...
  • Page 5 † Thermidistat Control can be configured for multiple use and staging, it must be configured for each specific application. } Dual Fuel thermostat is used with furnace and heat pump application. When applied with Carrier’s IdealHumidity™ series 58CVA/CVX and FE Indoor Models †† Must be installed in Dual--- Fuel Infinity system applications...
  • Page 6 CARRIER ACCESSORIES DESCRIPTION PART NO. 070---12 090---16 110---20 135---22 155---22 FILCCCAR0016 FILCCCAR0020 Cartridge Media Filter FILCCCAR0024 EXPXXUNV0016 EXPXXUNV0020 EZ Flex Media Filter with End Caps EXPXXUNV0024 EXPXXFIL0016 EXPXXFIL0020 Replacement EZ Flex Filter Media EXPXXFIL0024 KBAFR0401B14 KGAFR0501B17 External Bottom Return Filter Rack...
  • Page 7: Physical Data

    PHYSICAL DATA UNIT SIZE 070-12 090-16 110-20 135-22 155-22 All 58CVA; 58CVX Upflow High 54,000 71,000 89,000 107,000 125,000 35,000 47,000 59,000 70,000 82,000 OUTPUT CAPACITY BTUH* (Nonweatherized ICS) † 58CVX Downflow/Horizontal High 51,000 68,000 85,000 102,000 119,000 35,000 47,000...
  • Page 8 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,5,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54.
  • Page 9 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067...
  • Page 10 AIR DELIVERY - - CFM (With Filter)* External External Static Pressure (ESP) (IN WC) Static Unit Size Operating Mode Airflow Pressure Setting Range* (in. wc) 070 ---12 AIRFLOW (CFM) †† Low Heat 735 (615)† 0 ---0.50 High Heat 1180 (1060)† 0 ---1.0 1160 1165...
  • Page 11 DIMENSIONS (733mm) (664mm) 28-7/8" 26-1/8" (FLUE COLLAR) (641mm) 25-1/4" 2-7/16" (62mm) 22-9/16" AIRFLOW 1-5/16" (573mm) (33mm) 19" 13/16" JUNCTION BOX 13/16" (483mm) (21mm) 1-1/8" LOCATION 5-15/16" (21mm) (29mm) OUTLE T 4-13/16" (135mm) (122mm) 1/2" DIA. K.O.THERMOSTAT (22mm) WIRE ENTRY 9-5/8" (13mm) 11/16"...
  • Page 12 A08471...
  • Page 13 TYPICAL WIRING SCHEMATIC A95236 ELECTRICAL DATA OPERATING MAXIMUM MAXIMUM VOLTAGE RANGE WIRE VOLTS HERTZ MAXIMUM MINIMUM UNIT SIZE FUSE OR CKT PHASE UNIT AMPS LENGTH WIRE GAGE BKR AMPS† Maximum* Minimum* FT (M)‡ 070-12 115-60-1 30 (9.1) 090-16 115-60-1 29 (8.8) 110-20 115-60-1 15.1...
  • Page 14: Typical Installation

    TYPICAL INSTALLATION CONDENSING UNIT HUMIDIFIER GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW A02184...
  • Page 16 Media Filter is available as an option. _______________ Media Filter. Catalog No: 58CV ---5PD Copyright 2009 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.