Operation; Degaussing Instructions; Automatic Degaussing; Degaussing Instructions For Dlt Media - Garner HD-2 Series Operation And Installation Manual

Continuous degaussing system
Hide thumbs Also See for HD-2 Series:
Table of Contents

Advertisement

OPERATION

Degaussing Instructions

Automatic Degaussing

Press power button ON.
Step 1
Lift up on the drawer to unlock it and slide the drawer out
Step 2
until it stops
Place the media into the drawer and push the drawer to the
Step 3
closed position.
Note: Closing of the drawer automatically starts the degauss
cycle. After approximately 60 seconds, the LCD will read
"Remove Media" indicating that the media has been
degaussed and is ready for removal from the media drawer.
Remove media by lifting up and sliding out the drawer.
Step 4
Insert another hard drive or turn the power off and close the
Step 5
drawer.

Degaussing Instructions for DLT Media.

Remove the plastic protective cases. Simply follow the degaussing instructions above
for complete erasure.
Note: For DLT media that is to be re-used.
Although the data is completely degaussed in one operation, a second pass rotated at
90 degrees is required to smooth out any magnetic fluctuation. Note: If the second
pass is not completed, the tape drive may eject the tape from the tape drive and
indicate that the tape needs cleaning. The second pass at 90 degrees will correct this
condition.
If you have any questions, please call Garner Products, Inc. at 1-800-624-1903 or 916-
784-0200.
First Pass
HD-2 Operation and Installation Manual
Second Pass
Page 8