SAFETY
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
WARNING: In order to avoid a hazard for very young children, this appliance should be installed so that the lowest heated rail is at least 600mm
above the floor.
ELECTRICAL
• Must be installed by a registered electrician.
• The 12V 'safety isolating' transformer supplied must be located in a dry accessable location (do not cover with insulation).
50, 550, 750
• Distance from transformer to towel rail must be less than 2 metres (see FAQ's).
• Typical transformer locations include: Ceiling cavity / Wall cavity (behind switch plate) / Cupboard.
• Means for disconnection must be incorporated in the fixed wiring in accordance with wiring guidlines AS/NZS 3000:2000.
• The waterproof wirenut connectors provide an IPX7 rating.
insTRUCTiOns
• The towel rail may be installed in wet area electrical zones 1, 2 & 3 as specified in AS/NZS 3000:2000.
• Manufactured and tested to AS/NZS 60335.2.43.
• Minimum 50 mm clearance to surrounding surfaces.
intended for use by persons (including children) with
1. WALL PREPARATION
nsory or mental capabilities, or lack of experience and
• Corto-C heated towel rails may be fixed to ANY type of wall, timber stud, steel stud or masonry (solid or cavity).
hey have been given supervision or instruction concerning
• Stud walls (timber or steel) require timber nogs at the correct position for all legs. See table 1.0 for fixing dimensions.
by a person responsible for their safety. Children should
• If the precise position can't be determined early in the job, consider nogging with 18mm construction ply, covering a larger area.
ure that they do not play with the appliance.
• Be aware that attempting to fix into plasterboard or cement sheeting alone is NOT recommended. Plasterboard (in particular) will not hold long term.
o avoid a hazard for very young children, this appliance
2. PRE WIRING
o that the lowest heated rail is at least 600 mm above the
• First determine which side (left or right) you would like the cable to enter the heated towel rail.
• In general, the leg that is closest to the transformer and farthest from wet areas. eg. top left leg if the transformer is in the ceiling and shower is to the right.
• For stud walls drill a 10mm hole in the noggin for the low voltage wiring supplied at the leg position chosen. Typical layout see Table 1.0 for fixing dimensions.
y a registered electrician.
olating' transformer supplied must be located in a
ation (do not cover with insulation).
sformer to towel rail must be less than 2 metres.
r locations include:
vity
y (behind switch plate)
with
and
ection must be incorporated in the fixed wiring in
ncerning
wiring guidlines AS/NZS 3000:2000.
should
enut connectors provide an IPX7 rating
be installed in wet area electrical zones 1, 2 & 3 as
pliance
S 3000:2000.
bove the
tested to AS/NZS 60335.2.43
learance to surrounding surfaces.
TiOn
FIGURE 1
Fig 1.0
a
l rails may be fixed to ANY type of wall, timber stud, steel
olid or cavity).
or steel) require timber nogs at the correct position for all
for fixing dimensions.
ELECTRICIANS please ensure a copy of the installation
ion can't be determined early in the job, consider nogging
instructions is left with the end user for future reference.
uction ply, covering a larger area.
mpting to fix into plasterboard or cement sheeting alone
ded. Plasterboard (in particular) will not hold long term.
n
page 2 of 5
Fig 1.0
Fixed wiring
Transformer
12V wiring
Studs
Nogs
FIGURE 2
Fig 2.0
650, 850
page 2 of 5
Fixed wiring
Transformer
12V wiring
Studs
Nogs
Holes in legs
face bottom
CORTO-C INSTALLATION GUIDE | PAGE
FIGURE 3
2 OF 6