Nomenclature A5LCY-I-2010 Nomenclature Indoor Unit Brand : Acson Refrigerant : R410A Model Name : Wall Mounted Inverter System Type : Y series Capacity Index : 10,000 Btu/h : 15,000 Btu/h : 20,000 Btu/h : 25,000 Btu/h Chassis : J Series Model Type “...
Page 5
A5LCY-I-2010 Nomenclature Indoor Unit Brand : Acson Refrigerant : R410A Model Name : Ceiling Cassette : Ceiling Concealed : Ceiling Mounted Inverter System Type : Y series Capacity Index : 10,000 Btu/h : 15,000 Btu/h : 20,000 Btu/h : 25,000 Btu/h...
Nomenclature A5LCY-I-2010 Outdoor Unit Brand : Acson Refrigerant : R410A Model Name : Single Split Condensing Unit Inverter System Type : Y series Capacity Index : 10,000 Btu/h : 15,000 Btu/h : 20,000 Btu/h : 25,000 Btu/h Chassis : C Series...
A5LCY-I-2010 Features Features Self Diagnosis The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the system. The error will be refl ected by the blinking of the LED lights and by wireless or wired* handset 7- segment display.
Application Information A5LCY-I-2010 Application Information Operating Range Ensure the operating temperature is in allowable range. Heatpump Heating Cooling Standard point Indoor temp. (°CDB) Indoor temp. (°CWB) Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure...
A5LCY-I-2010 Application Information Operation Guide Transmission source OFF timer setting • The source where the signal will be transmitted. • Press the TIMER OFF button will activate the off timer function. Signal transmission indication • Set the desired off time by pressing the TIMER OFF button •...
Page 18
Application Information A5LCY-I-2010 Controller Netware 3C ON/OFF Button ON TIMER Button • Starting Operation: • Enable/disable the Event 1, 2 and 3 ON TIMER setting When the unit is turned off, press the ON/OFF button. mode The operation LED lights and the unit is turned on. OFF TIMER Button •...
A5LCY-I-2010 Application Information Installation Guideline Safety Precautions WARNING CAUTION Please take note of the following important points • Installation and maintenance should be performed by qualifi ed when installing. persons who are familiar with local code and regulation, and • Do not install the unit where leakage of fl...
Application Information A5LCY-I-2010 Installation Diagram Cut thermal insulation pipe to an appropriate Wall Mounted 30mm or more from ceiling Caulk pipe length and wrap it with hole gap tape, making sure that no with putty. gap is left in the insulation Front panel pipe’s cut line.
Page 21
A5LCY-I-2010 Application Information Routing of Piping • The refrigerant piping can be routed to the unit in a number of ways (left or right from the back of the unit), by using the cut-out holes on the casing of the unit . Bend the pipes carefully to the required position in order to align it with the holes.
Page 22
Application Information A5LCY-I-2010 • Fix the installation plate fi rmly to the wall, without tilting to left or right. Use a plumb line, if available. Use tape measure as shown. Recommended mounting plate Position the end of a tape measure retention spots (5 spots in all) Through the wall...
Page 23
A5LCY-I-2010 Application Information Water Drainage Piping • The indoor drain pipe must be downward gradient for smooth drainage. Avoid situation as shown in fi gure below. Water Drainage Water Retention dipped Water Water Water into leaking leaking leaking water Drain Correct Wrong Wrong...
Page 24
Application Information A5LCY-I-2010 Ceiling Cassette Drain Piping Thermal Insulation Wrap the insulated pipe with the finishing tape from bottom to top Front Panel Air Filter (behind the grille) Air Intake Grille Air Discharge Louver Preliminary Site Survey • Electrical supply and installation is to confi rm to local authority’s (e.g. National Electrical Board) codes and regulations.
A5LCY-I-2010 Application Information Unit Installation 770.0 mm (Hanging rod) 15.0 18.0 538.0 529.0 19.0 32.0 580.0 ~ 610mm (CEILING OPENING MEASUREMENT) Piping Direction A5CKY-C A5CKY-E • The indoor unit must be away from heat and steam sources (avoid installing it near an entrance). •...
Application Information A5LCY-I-2010 Drain Piping Work • Drain pipe must be downward gradient for smooth drainage. • Avoid the drain pipe from up and down slope to prevent reversal fl ow. INDOOR UNIT • During the drain pipe connection, be careful not to exert extra force on the drain connector at the indoor unit.
Page 27
A5LCY-I-2010 Application Information Note: Install the front frame panel fi rmly to prevent cool air leakage which will cause condensation and water dripping. Fresh Air Intake For A5CKY-E Unit Take off the panel from the indoor unit Remove the PE foam from the drain pan and another one on the unit. Remove the pre-punched panel on the CKC unit with a screwdriver.
Page 28
Application Information A5LCY-I-2010 Fig. 2 The direction of the fresh air intake is shown as fi g. 2. Sealing Material • It is possible to seal one of the four air discharge outlet (sealing two or more air discharge outlet could cause a malfunction).
Page 29
A5LCY-I-2010 Application Information Possible Opening Dimension for Duct Connection Note: 1. Avoid to use the short duct on which the air discharge grille can be completely closed, to prevent evaporator freezing. 2. In order to prevent condensation forming, be sure that there is suffi cient thermal insulation and no leakage of cool air when installing the short duct.
Page 30
Application Information A5LCY-I-2010 Preliminary Survey • Electrical supply and installation is to confi rm to local authority’s (e.g. National Electrical Board) codes and regulations. • Voltage supply fl uctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformers which can cause high supply fl...
A5LCY-I-2010 Application Information Ceiling Convertible Preliminary Site Survey • Electrical supply and installation is to confi rm to local authority’s (e.g. National Electrical Board) codes and regulations. • Voltage supply fl uctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformers which can cause high supply fl...
Page 32
Application Information A5LCY-I-2010 Please ensure that the following steps are taken: • Check the gradient for drainage fl ow as recommended in Figure 4. • Provide clearance for easy servicing and optimal air fl ow as shown in Figure 5. •...
A5LCY-I-2010 Application Information Under Ceiling Installation Install the Suspension Bolts 1. Install the suspension bolts so that it can support the indoor unit. 2. Adjust the distance to ceiling before installation. 3. Refer to the dimension given (Fig. 5) to install the unit. Install the Indoor Unit 1.
Page 34
Application Information A5LCY-I-2010 Floor Standing Installation 1. Refer to the dimension as illustrated when installing the mounting bracket. 2. Determine the pipe hose position using the rear piping hole. Drill the pipe hole at the slight downward slant to the outdoor side. MOUNTING BRACKET HOCK THE UNIT ON THE MOUNTING BRACKET...
A5LCY-I-2010 Application Information Piping and Drain Hose Installation Under Ceiling Type 1. The piping direction can be 2 ways as illustrated. 2. The drain hose is only 1 way. Floor Standing Type How to Install the Drain Hose 1. Remove the 2 screws and the drain pipe holder. 2.
Page 36
Application Information A5LCY-I-2010 How to Remove the Air Inlet Grille 1. Remove the air inlet grille by both hands as the direction shown. 2. Loosen the screws for fi xing the panel arm (3 screws – Left, Right and Center). Do not remove the screws at this time.
Page 37
A5LCY-I-2010 Application Information How to Install the Air Filter To Adjust the Vane Direction Adjust the vane linkage as the direction shown to get the required vane direction. Dimension of the Fresh Air Intake Hole 64.0 70.0...
Page 38
Application Information A5LCY-I-2010 Outdoor Unit Installation • Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airfl ow, follow the installation guidelines below. Wall facing one side Walls facing two sides More than 50 More than 100 More than 100 More...
A5LCY-I-2010 Application Information Refrigerant Piping Piping Length and Elevation If the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the fl ow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective.
Page 40
Application Information A5LCY-I-2010 Piping Works • Do not use contaminated or damaged copper tubing. Do not remove plastic, rubber plugs and brass nuts from the valves, fi ttings, tubings and coils until you are ready to connect suction or liquid line into valves or fi...
A5LCY-I-2010 Application Information Vacuuming and Charging Purging The Piping And The Indoor Unit Except for the outdoor unit which is pre-charged with refrigerant, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor.
Page 42
Application Information A5LCY-I-2010 Special Precautions when Dealing with R410A Unit R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
Engineering & Physical Data A5LCY-I-2010 Component Data - Heat Pump OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5WMY 10JR A5WMY 15JR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY GLASS REINFORCED ACRYL GLASS REINFORCED ACRYL MATERIAL STYRENE RESIN...
Page 53
A5LCY-I-2010 Engineering & Physical Data Component Data - Heat Pump OUTDOOR UNIT A5LCY 20CR A5LCY 25CR MODEL INDOOR UNIT A5WMY 20JR A5WMY 25JR TYPE CROSS FLOW FAN CROSS FLOW FAN QUANTITY MATERIAL RESIN ASG RESIN ASG INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in...
Page 54
Engineering & Physical Data A5LCY-I-2010 Component Data - Heat Pump OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5CKY 10CR A5CKY 15CR TYPE TURBO TURBO QUANTITY MATERIAL ABSG20 ABSG20 INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 315 / 12.4 315 / 12.4...
Page 55
A5LCY-I-2010 Engineering & Physical Data Component Data - Heat Pump OUTDOOR UNIT A5LCY 20CR MODEL INDOOR UNIT A5CKY 20CR TYPE TURBO QUANTITY MATERIAL ABSG20 INDOOR FAN DRIVE DIRECT DIAMETER mm/in 315 / 12.4 LENGTH mm/in 163 / 6.4 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP)
Page 56
Engineering & Physical Data A5LCY-I-2010 Component Data - Heat Pump OUTDOOR UNIT A5LCY 20CR A5LCY 25CR MODEL INDOOR UNIT A5CKY 20ER A5CKY 25ER TYPE TURBO TURBO QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 486 / 19.1 486 / 19.1 LENGTH mm/in...
Page 57
A5LCY-I-2010 Engineering & Physical Data Component Data - Heat Pump OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5CCY 10CR A5CCY 15CR TYPE SIROCCO SIROCCO QUANTITY MATERIAL GALVANISED STEEL GALVANISED STEEL INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 164 / 6.5 164 / 6.5...
Page 58
Engineering & Physical Data A5LCY-I-2010 Component Data - Heat Pump OUTDOOR UNIT A5LCY 20CR A5LCY 25CR MODEL INDOOR UNIT A5CCY 20CR A5CCY 25CR TYPE SIROCCO SIROCCO QUANTITY MATERIAL GALVANISED STEEL GALVANISED STEEL INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 160 / 6.3 160 / 6.3 LENGTH mm/in...
Page 59
A5LCY-I-2010 Engineering & Physical Data Component Data - Heat Pump OUTDOOR UNIT A5LCY 15DR A5LCY 20CR MODEL INDOOR UNIT A5CMY 15ER A5CMY 20ER TYPE SIROCCO SIROCCO QUANTITY MATERIAL INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 145 / 5.7 145 / 5.7 LENGTH mm/in 200 / 8.9...
Page 60
Engineering & Physical Data A5LCY-I-2010 Component Data - Heat Pump OUTDOOR UNIT A5LCY 25CR MODEL INDOOR UNIT A5CMY 25ER TYPE SIROCCO QUANTITY MATERIAL INDOOR FAN DRIVE DIRECT DIAMETER mm/in 145 / 5.7 LENGTH mm/in 200 / 8.9 TYPE INDUCTION INDOOR FAN MOTOR QUANTITY INDEX OF PROTECTION (IP) IP20...
A5LCY-I-2010 Engineering & Physical Data Safety Devices Data OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5WMY 10JR A5WMY 15JR TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE kPa / psi TYPE SAFETY LOW PRESSURE SWITCH OPEN kPa / psi...
Page 62
LOW PRESSURE SWITCH OPEN kPa / psi DEVICE CLOSE kPa / psi PHASE SEQUENCER DISCHARGE THERMOSTAT °C / °F SETTING OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5CCY 10CR A5CCY 15CR TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE...
Page 63
A5LCY-I-2010 Engineering & Physical Data Safety Devices Data OUTDOOR UNIT A5LCY 25CR MODEL INDOOR UNIT A5CMY 25ER TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE kPa / psi TYPE SAFETY LOW PRESSURE SWITCH OPEN kPa / psi DEVICE CLOSE kPa / psi PHASE SEQUENCER DISCHARGE THERMOSTAT...
Outline and Dimension A5LCY-I-2010 Outline and Dimension Outdoor Unit Model: A5LCY 10/15DR All dimensions are in mm 105.5 Note: Dimension in mm Outdoor Unit Model: A5LCY 20/25CR Note: Dimension in mm...
Page 65
A5LCY-I-2010 Outline and Dimension Indoor Unit Model: A5WMY 10/15JR Note: Dimension in mm Indoor Unit Model: A5WMY 20/25JR 1065 Note: Dimension in mm...
Page 66
Outline and Dimension A5LCY-I-2010 Indoor Unit Model: A5CKY 10/15/20CR MODEL A5CKY 10/15/20CR Note: Dimension in mm Indoor Unit Model: A5CKY 20/25ER MODEL A5CKY 20/25ER Note: Dimension in mm...
Electrical Data A5LCY-I-2010 Electrical Data OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5WMY 10JR A5WMY 15JR INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER...
Page 69
A5LCY-I-2010 Electrical Data OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5CKY 10CR A5CKY 15CR INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.28...
Page 70
1518 RATED RUNNING CURRENT (COOLING) 5.66 7.25 RATED RUNNING CURRENT (HEATING) 5.84 6.52 LOCKED ROTOR AMP. OUTDOOR UNIT A5LCY 10DR A5LCY 15DR MODEL INDOOR UNIT A5CCY 10CR A5CCY 15CR INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50...
Page 71
A5LCY-I-2010 Electrical Data OUTDOOR UNIT A5LCY 20CR A5LCY 25CR MODEL INDOOR UNIT A5CCY 20CR A5CCY 25CR INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.61 0.74...
Page 72
Electrical Data A5LCY-I-2010 OUTDOOR UNIT A5LCY 25CR MODEL INDOOR UNIT A5CMY 25ER INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.49 MOTOR OUTPUT POLES INSULATION GRADE POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER...
Service and Maintenance A5LCY-I-2010 Service and Maintenance Warning • Disconnect from main supply before servicing the air conditioner. • The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedures Period...
A5LCY-I-2010 Service and Maintenance Air Filter 1. Open the front panel. • Hold the panel at the recesses on the main unit (2 recesses on right and left sides) and lift it until it stops. Recess on main unit 2. Pull out the air fi lters. •...
Troubleshooting A5LCY-I-2010 Troubleshooting Fault Condition When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.
Page 85
A5LCY-I-2010 Troubleshooting By means of diagnostic fl ow chart: Generally, there are two kinds of problems, i.e. starting failure and insuffi cient cooling / heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insuffi cient cooling / heating”.
Page 86
Troubleshooting A5LCY-I-2010 Change the contactor Coil burnt Faulty Condenser fan contactor Change the contacts Contact faulty Repair or replace the motor contactor Fan motor faulty Blown Other electrical Repair or change if necessary component faulty Change the contactor Coil burnt Faulty Evaporator contactor...
Page 87
A5LCY-I-2010 Troubleshooting ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insuffi cient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
Page 88
Troubleshooting A5LCY-I-2010 Insuffi cient heating Indoor/outdoor coil dirty Clean the coil (clogged) Restricted circulation Clean the fi lter Indoor air fi lter dirty Change or repair the motor Fan motor malfunction Obstruction at air inlet Remove the obstruction /outlet of indoor / outdoor unit Windows / doors wide High heating...
A5LCY-I-2010 Troubleshooting Indicator Lights IR Signal Receiver When an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will respond as below to confi rm acceptance of the signal transmission. ON to OFF 1 Long Beep OFF to ON 2 Short Beep Pump down/Cool force on...
Page 90
Troubleshooting A5LCY-I-2010 Error Code Diagnosis by Wireless Handset GS02 SWING TURBO MODE QUIET SLEEP TIMER ON TIMER CANCEL CLOCK CANCEL TIMER OFF Diagnosis Step 1. Hold down ON TIMER CANCEL button or OFF TIMER CANCEL button for 5 seconds, a “ ”...
Page 91
A5LCY-I-2010 Troubleshooting Error Code Diagnosis by Wired Handset Netware 3C Error code flashes e.g. A1 Error display using normal running Error code flashes e.g. A1 Error display using unit last state memory...
Page 93
A5LCY-I-2010 Troubleshooting ERROR ERROR DESCRIPTION CODE COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND INVERTER PCB) OPEN PHASE OR VOLTAGE UNBALANCE HEAT SINK THERMISTOR SHORT/OPEN CAPACITY SETTING ERROR INSUFFICIENT GAS DC VOLTAGE OUT OF RANGE COMMUNICATION ERROR COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND IPM PCB) INSTALLATION ERROR PIPING &...
Page 94
Troubleshooting A5LCY-I-2010 Parameter Parameter Description Unit/ range Number Current control zone 0-Normal, Other-Active Oil return status 0-Normal, Other-Active De-ice setting 0-Normal, Other-Active Dew drop setting 0-Normal, Other-Active Heatsink protection zone 0-Normal, Other-Active Turbo setting 0-Normal, Other-Active Silent setting 0-Normal, Other-Active Low ambient zone 0-Normal, Other-Active Defrost status...
A5LCY-I-2010 Exploded View and Part List Exploded View and Part List Outdoor Unit Model: A5LCY 10/15DR Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
Page 96
Exploded View and Part List A5LCY-I-2010 Outdoor Unit Model: A5LCY 10/15DR No Description No Description Assy. Botttom Frame 16 Assy. Control Box Top Plate 17 EXV Solenoid Coil Right Side Plate 18 Assy. 4WV Coil Left Side Plate 19 Reactor Front Panel 20 Assy.
Page 97
A5LCY-I-2010 Exploded View and Part List Outdoor Unit Model: A5LCY 20/25CR No Description No Description Assy. Base Fan 11 Panel, Right Back Panel, Service 12 Assy. Valve Bracket Panel, Top 13 Assy. 4WV Panel, Front/Left 14 Assy. EXV Assy. Coil 15 Assy.
Exploded View and Part List A5LCY-I-2010 Indoor Unit Model: A5WMY 10/15JR No Description No Description Assy. Front Grille 11 Blower Panel 12 Assy. Installation Plate Disch. Grille Hor.Blade Assy. 13 Right Side Panel Assy. Bottom Frame 14 Cover, Drip Proof Assy.
Page 99
A5LCY-I-2010 Exploded View and Part List Indoor Unit Model: A5WMY 20/25JR No Description No Description 10 Assy. Control Box Assy. Chasis 11 Assy. Control Module Motor 12 Cover, Control Box Blower 13 Cover, Service Fan Bush 14 Assy. Mounting Plate Cover, Motor 15 Assy.
Page 100
Exploded View and Part List A5LCY-I-2010 Indoor Unit Model: PLCKY-CR No Description No Description 11 Lingkage, Motor Cover Frame 12 Assy. Bracket Receiver (LED/SLM) Assy. Intake Grille B 13 Assy. Motor Filter 14 Crank, Connector Lock, Grille 15 Louver, Holder Discharge, Foam 16 Cross, Crank Discharge, Foam LED...
Page 101
A5LCY-I-2010 Exploded View and Part List Indoor Unit Model: A5CKY 10/15/20CR Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
Page 102
Exploded View and Part List A5LCY-I-2010 Indoor Unit Model: A5CKY 10/15/20CR No Description No Description 14 Bush, Pump Assy. Base 15 Assy. Drain Pump Support Bracket Assy. Casing 16 Assy. End Plate Support Assy. Heat Exchanger 17 Clip, Coil Sensor Cover, Fan 18 Support, Heat Exchanger Blower...
Page 103
A5LCY-I-2010 Exploded View and Part List Indoor Unit Model: PLCKY-ER No Description No Description Front, Frame Crank Connector Assy., Intake Grille Assy., LED Assy., Air Discharge Main 10 Wire, Guide Assy., Air Discharge Main Right 11 Cover, Cross Connector Assy., Air Discharge Main Left 12 Assy., Cover Corner A Air Filter, CK-A/AR 13 Assy., Cover Corner B...
Page 104
Exploded View and Part List A5LCY-I-2010 Indoor Unit Model: A5CKY 20/25ER Description Description Assy. Base Pan 16 Cover, Wire B Assy. Coil 17 Bracket, Hanger A Assy. Coil Bracket 18 Bracket, Hanger B Assy. Drain Pump Mounting 19 Bracket, Hanger C Assy.
Page 105
A5LCY-I-2010 Exploded View and Part List Indoor Unit Model: A5CCY 10/15/20/25CR No Description No Description Cabinet Assy. Blower Left 10 Motor Assy. Fan Deck Parts Not in Diagram Assy. Heat Exchanger Assy. Drain Pan Handset, Wired Assy. Secondary Drain Pan Air Filter Hanger Holder, Thermistor...
Page 106
Exploded View and Part List A5LCY-I-2010 Indoor Unit Model: A5CMY 15/20/25ER Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
Page 107
A5LCY-I-2010 Exploded View and Part List Indoor Unit Model: A5CMY 15/20/25ER No Description No Description 12 Assy. Panel Bottom Assy. Top Panel 13 Cover, Hanger L1 (C) Assy. Heat Exchanger 14 Cover, Hanger L2 (D) Assy. Vane 15 Cover, Hanger R1 (A) Assy.
Page 108
While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of speci fications andequipment are also subject to change to suit local conditions and equirements and not all models are available in every market.