Storage Enclosure Operations; Removing Chassis Level Storage Enclosures - Cisco UCS S3260 Manual

Hide thumbs Also See for UCS S3260:
Table of Contents

Advertisement

Cisco UCS S3260 System Storage Management
Step 5
Example
The following example sets the state of the virtual drive 1001 in the virtual drive container 1 to
transport ready:
UCS-A# scope chassis
UCS-A /chassis# scope virtual-drive-container 1
UCS-A /chassis/virtual-drive-container# scope virtual-drive 1001
UCS-A /chassis/virtual-drive-container/virtual-drive# set admin-state transport-ready
UCS-A /chassis/virtual-drive-container/virtual-drive# commit-buffer

Storage Enclosure Operations

Removing Chassis Level Storage Enclosures

You can remove the storage enclosure corresponding to HDD expansion tray in Cisco UCS Manager after it
is physically removed. You cannot remove server level or any other chassis level storage enclosures.
Procedure
Step 1
Command or Action
UCS-A
/chassis/virtual-drive-container/virtual-drive#
commit-buffer
Command or Action
UCS-A# scope chassis
chassis-id
Storage Enclosure Operations
Purpose
All virtual drives on a disk
Note
group must be marked as
hidden before migrating or
unassigning the disks from a
server node.
• transport-ready — Choose this option
for the safe migration of the virtual drive
from one server to another.
Note
When a virtual drive is marked
as transport ready, the storage
controller will disable all IO
operations on the drive. In
addition, after zoning the virtual
drive and importing the foreign
configuration, the virtual drive
will be operational.
Commits the transaction to the system
configuration.
Purpose
Enters chassis mode for the specified chassis.
Cisco UCS S3260 System Storage Management
13

Hide quick links:

Advertisement

Table of Contents
loading