PARAMETER LIST
Parameter
Name
Automatic switchover
139
frequency from inverter to
bypass operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
144
Speed setting switchover
PU display language
145
selection
Stall prevention level at 0V
148
input
Stall prevention level at 10V
149
input
Output current detection
150
level
Output current detection
151
signal delay time
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection
154
during stall prevention
operation
RT signal function validity
155
condition selection
Stall prevention operation
156
selection
157
OL signal output timer
AM terminal function
158
selection
Automatic switchover
159
frequency range from
bypass to inverter operation
160
User group read selection
Frequency setting/key lock
161
operation selection
Automatic restart after
162
instantaneous power failure
selection
163
First cushion time for restart
First cushion voltage for
164
restart
Stall prevention operation
165
level for restart
Output current detection
166
signal retention time
Output current detection
167
operation selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
15
Setting
Initial
Parameter
Range
Value
0 to 60Hz,
9999
9999
0 to 400Hz
1Hz
0 to 360s
0.5s
1Hz
0 to 400Hz
0.5s
0 to 360s
0, 2, 4, 6, 8,
10, 102, 104,
4
106, 108, 110
0 to 7
1
150%
0 to 220%
200%
0 to 220%
0 to 220%
150%
0s
0 to 10s
5%
0 to 220%
0 to 1s
0.5s
1
0, 1
0
0, 10
0 to 31, 100,
0
101
0 to 25s, 9999
0s
1 to 3, 5 to 14,
17, 18, 21, 24,
1
32 to 34, 50,
52, 53, 70
0 to 10Hz,
9999
9999
0
0, 1, 9999
0
0, 1, 10, 11
0, 1, 2, 10, 11,
0
12
0 to 20s
0s
0%
0 to 100%
150%
0 to 220%
0.1s
0 to 10s, 9999
0, 1
0
9999
0, 10, 9999
9999
0, 9999
Name
User group registered
172
display/batch clear
173
User group registration
174
User group clear
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal function
185
selection
CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal function
188
selection
RES terminal function
189
selection
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
232 to
Multi-speed setting (8 speed
239
to 15 speed)
Soft-PWM operation
240
selection
Analog input display unit
241
switchover
Setting
Initial
Range
Value
9999, (0 to 16)
0
9999
0 to 999, 9999
9999
0 to 999, 9999
0 to 20, 22 to
28, 42 to 44,
60
50, 60, 62, 64
to 71, 74, 9999
0 to 20, 22 to
28, 42 to 44,
61
50, 61, 62, 64
to 71, 74, 9999
0
0 to 20, 22 to
1
28, 42 to 44,
50, 62, 64 to
2
71, 74, 9999
3
0 to 20, 22 to
28, 42 to 44,
4
50, 62 to 71,
74, 9999
5
6
0 to 20, 22 to
28, 42 to 44,
24
50, 62, 64 to
71, 74, 9999
25
62
0 to 8, 10 to
0
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
1
70, 84, 85, 90
to 99,
100 to 108,
2
110 to 116,
120, 125 to
128, 130 to
3
136, 139, 141
to 147, 164,
170, 184, 185,
4
190 to 199,
9999
0 to 8, 10 to
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
99
70, 84, 85, 90,
91, 94 to 99,
100 to 108,
110 to 116,
120, 125 to
128, 130 to
136, 139, 141
9999
to 147, 164,
170, 184, 185,
190, 191, 194
to 199, 9999
0 to 400Hz,
9999
9999
1
0, 1
0, 1
0