Response Time:
• MC4700 and MS4700
Table 14-1
Response Time for 12 mm MC4700 and MS4700
Protected Height Designator
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
Note: MC4700-12 is only available up to 1200 mm protective heights.
OMRON SCIENTIFIC TECHNOLOGIES INC.
Fremont CA USA
Tel: 1/888/510-4357 in USA and Canada
Response Times for 12 mm systems
No. of Beams
Solid State
16
7.5
32
9.2
48
10.9
64
12.5
80
14.2
96
15.8
112
17.5
128
19.2
144
20.8
160
22.5
176
24.1
192
25.8
208
27.5
224
29.1
240
30.8
256
32.4
52
Response Times – mS
Mechanical Relay
N.O.
N.C.
17.5
27.5
19.2
29.2
20.9
30.9
22.5
32.5
24.2
34.2
25.8
35.8
27.5
37.5
29.2
39.2
30.8
40.8
32.5
42.5
34.1
44.1
35.8
45.8
37.5
47.5
39.1
49.1
40.8
50.8
42.4
52.4