Do you have a question about the u350 and is the answer not in the manual?
Questions and answers
Laura Russell
February 17, 2025
Boneco U350- water level light flashes but water tank is full - air is coming from top vent but is not humidified and after a few minutes the unit shuts
1 comments:
Mr. Anderson
February 17, 2025
The Boneco U350 may have a flashing water level light even when the water tank is full due to incorrect installation of the tank, blockage in the water flow, or sensor malfunction. If the unit is not humidifying before shutting off, it could be due to an obstruction in the ultrasonic element, incorrect placement, or an issue with the sensor detecting water availability. Checking the proper installation of the tank, ensuring there is no blockage, and verifying sensor functionality may resolve the issue.
TABLE OF CONTENTS Technical data Comfort functions Switching the heater on and off Introduction Fragrance container Valuable information about humidity Items included Timer functions Setting the OFF timer Overview and part names Setting the ON timer Indicators on the display Cleaning and maintenance Care instructions Keypad...
TECHNICAL DATA Mains voltage 230 V / 50 Hz Power consumption 110 W Humidity output 500 g/h* (3.170 gal/day) For rooms up to 60 m / 150 m (645 sq ft / 5,300 cubic ft) Water capacity 5.0 liters (1.32 gallons) Dimensions L×W×H 308×165×325 mm (12.1×6.5×12.79 in.) Weight (empty)
It makes your eyes and throat feel dry while significantly af- The BONECO U350 is designed for convenient, fully au- fecting physical comfort. Not only does this affect adults, tomated operation.
INDICATORS ON THE DISPL AY Overview of all indicators on the display Symbol Meaning Symbol Required action Current or desired humidity Refill the water Fully automated operation Change the water in the appliance Heater turned on Replacing Ionic Silver Stick ®...
KEYPAD Keypad on the appliance Button Function Switching unit on and off Regulating output “AUTO” comfort mode Switch heater on/off Access the timer function Change the humidity...
A250 AQUA PRO PREPARATION ON WATER HARDNESS 3. Refer to the table to determine the duration of effect The BONECO U350 is supplied with an A250 AQUA PRO. of the A250 AQUA PRO: Remove the packaging of the BONECO A250 AQUA PRO.
Fill the tank with cold tap water. Plug the power cord into a power outlet. to switch on the BONECO U350. Direct the mist into the open room. again to switch off the BONECO U350 Select the desired output level using the button. entirely.
THE RIGHT LOCATION THE RIGHT LOCATION The BONECO U350 releases more than half a liter of wa- ter into the air per hour. This makes it important to set up the appliance in the right location. Do not place the BONECO U350 directly on the floor, since the moisture from the mist can damage floor surfaces such as parquet or delicate carpeting.
HUMIDIT Y AND ULTR ASONIC SAVE SETTINGS CONTROLLING HUMIDITY REGULATING PERFORMANCE The BONECO U350 saves the last-used settings when it The humidity can be set between 30% and 70%. In the Tap the symbol multiple times until the desired is switched off. However, if the appliance is disconnected “Co”...
COMFORT FUNCTIONS SWITCHING THE HEATER ON AND OFF FRAGRANCE CONTAINER The BONECO U350 is equipped with a heater that can be Commercially available scented aromatic substances for turned on and off. It warms the outgoing mist up to ap- humidifiers can be added to the fragrance container on proximately 35 °C (95 °F), so that the room temperature...
BONECO run time is displayed. The BONECO U350 switches on after the defined time and U350 before you return home, so that when you get back operates with the selected settings. you have the perfect home climate waiting for you.
® Daily Check the water level; add water if necessary the BONECO U350. Stagnant water can also impair clean- liness and lead to unpleasant odors. This means regular After 1 week without operation Empty and clean the BONECO U350...
Never clean the membrane using sharp objects or aggressive cleaning agents; doing so can damage the BONECO U350 and voids the warranty! 5. Wait 30 minutes to allow the solution to take effect. 6. Rinse the water tank with tap water. Remove re-...
BONECO U350. ® ® water, making a vital contribution to health and cleanli- You can obtain replacements from your BONECO special- ness. The Ionic Silver Stick is also subject to wear and 2. Take out the used Ionic Silver Stick and dispose of ist dealer or our online store at www.shop.boneco.com.
Page 18
BONECO is a registered trademark of BONECO AG, Switzerland...
Need help?
Do you have a question about the u350 and is the answer not in the manual?
Questions and answers
Boneco U350- water level light flashes but water tank is full - air is coming from top vent but is not humidified and after a few minutes the unit shuts
The Boneco U350 may have a flashing water level light even when the water tank is full due to incorrect installation of the tank, blockage in the water flow, or sensor malfunction. If the unit is not humidifying before shutting off, it could be due to an obstruction in the ultrasonic element, incorrect placement, or an issue with the sensor detecting water availability. Checking the proper installation of the tank, ensuring there is no blockage, and verifying sensor functionality may resolve the issue.
This answer is automatically generated