Further details regarding the individual steps
Removing the burner
4x
G
D
B
1. Turn off the ON/OFF switch.
2. Shut off the gas supply.
3. Pull the power cables from fan
motor A, gas train B, ignition unit
C and electrodes D.
4. Pull Venturi extension E off the
fan.
Checking the burner gasket and burner gauze assembly
Check burner gasket A for damage
and replace if necessary.
A
Commissioning, inspection, maintenance
(cont.)
C
E
F
5. Undo the fitting from gas supply
pipe F.
6. Undo 4 screws G. Remove the
burner.
!
Please note
Prevent damage.
Never rest the burner on the
burner gauze assembly.
Replace the burner gauze assembly if it
is damaged.
41