Clock Mode Programming
If the Clock Mode is not enabled via the Analyst Personal Computer Interface
the following screens will not be visible nor accessable by Touch Programming .
When the Clock Mode is enabled, the Clock Menu Screen will be the first screen
that is displayed when in Touch Programming.
Programming the Clock Time and Alarm settings follows the same sequence
as Touch Programming.
Clock
Main Menu Selection
Bridge Contacts 1 & 2
with wetted fingers to
access Clock Mode..
Bridge Contacts 1 & 2
Clock Alarm
with wetted fingers to
Off
toggle Clock Alarm on/off.
Short Contacts 1 & 2 with a Coin
Short Contacts 1 & 2 with a Coin
or other highly conductive metal object
or other highly conductive metal object
to access Clock Alarm setting screen.
to access Clock time setting screen.
Short Contacts 2 & 3 with Coin
to increment digit value.
(Digit being programmed flashes)
Setting Alarm
Time
Short Contacts 1 & 2
with a Coin selects the
next programming option.
Short Contacts 2 & 3 with Coin
Setting Time
to increment digit value.
wo/Alarm
(Digit being programmed flashes)
Bridge Contacts 1 & 2
Short Contacts 1 & 2
with wetted fingers to
with a Coin selects
select next digit.
the Clock Mode.
Alarm will sound and Taclite
Clock Mode
Flashes once
will flash for one minute at
wo/Alarm
per second.
this time every 24 hours.
Clock and Alarm times are displayed
Short Contacts 1 & 2 with a Coin until unit
using a 24 hour Clock. 15:16 = 3:16 pm.
issues two beeps and exits to Surface Mode.
Clock Mode must be exited before commencing a Dive.
5
TYPES OF AUDIBLE WARNINGS
Most Warnings are issued for five seconds and repeated every two minutes
Single Beep
Double Beep
Two Tone
High to Low Sweep
Low to High Sweep
Any time the "WARNING" legend is on and/or flashing, some parameter is out of
bounds. Look for the offending parameter that is flashing on and off every second.
BATT
Any time the 'BATT' legend is on, battery voltage is below 2.5 volts
and batteries should be changed. When 'BATT" legend is flashing,
battery voltage is below 2.2 volts and batteries MUST be changed.
Dive Number
& Time to Fly
Clock Alarm
(Never Flash)
On
D
I
V
E
BOTTOM
Bottom Time
(Never Flashes)
NDC Time Remain
(Flashes when two minutes
or less remain before entering
Decompression mode)
REMAIN TIME
WARNING
A
S
NDC
C
E
N
T
BOTTOM
DEPTH
Depth
Bridge Contacts 1 & 2
(Flashes when user
with wetted fingers to
set maximum depth
is exceeded.)
select next digit.
Setting Time
w/Alarm
REMAIN TIME
WARNING
A
S
NDC
C
E
N
T
BOTTOM
. .
PO2
Depth
(Flashes when user
Bridge Contacts 1 & 2
(Flashes when user set maximum
set maximum PO2
depth or 327 feet is exceeded or
with wetted fingers to
value is exceeded.)
sensor is malfunctioning.)
select next digit.
Clock Mode
w/Alarm
REMAIN TIME
WARNING
DEC
BOTTOM
(Flashes when depth
is less than Ceiling.)
Depth Alarm, two minutes of NDC Time Remaining,
Entering Decompression.
Oxygen Toxicity (CNS, OTU, PO2).
Sensor Malfunction.
Ascent Rate (Continuous).
Depth Shallower than Decompression Ceiling (Continuous).
WARNING
When 'METRIC' legend
is on, the unit is
computing in Metric
METRIC
variables and displaying
data in Metric units.
Temperature
(Flashes if less than 20 or
greater than 99 degrees F,
or sensor is malfunctioning)
FLY
TEMP
SURF
MAX
DEPTH
Max Depth
Surface Interval
(Never Flashes)
(Never Flashes)
Ascent Rate Bar Graph
Temperature
(Flashes when ascending too
(Flashes if less than 20 or
fast based on Ascent rate
greater than 99 degrees F,
alarm setting via Analyst)
or sensor is malfunctioning)
Air Only
REMAIN TIME
WARNING
TEMP
TEMP
A
S
NDC
C
E
N
T
BOTTOM
DEPTH
MAX
DEPTH
Air Only
Depth
Sensor Failure
(Flashes when 327 feet
(Sensor malfunction,
is exceeded or sensor
'T' is Temp Sensor
is malfunctioning)
'd' is Depth Sensor)
Main
WARNING
TEMP
Screen
DEPTH
Alternate
Screen
CNS
Sensor Failure
(Flashes when user
(Sensor malfunction,
set maximum value
'T' is Temp Sensor
is exceeded.)
'd' is Depth Sensor)
Ceiling
(Flashes if depth
is less than ceiling.)
Main
TEMP
CEIL
WARNING
Screen
DEPTH
MAX
DEPTH
Alternate
Screen
OTU
Depth
(Flashes when user
set maximum value
is exceeded.)
6
Cochran
Undersea Technology
www.divecochran.com
Ph 972.644.6284
800.856.3483 (US)
"CardEMC16_FO2" 01December06
Fax 972.644.6286
877.288.3483 (US)
Diagnostic Mode
(Unit Turning on)
Turn on by touching
REMAIN TIME FLY
WARNING
TEMP
closest two Contacts
D
A
S
NDC
on the side with
I
C
V
DEC
E
E
wetted finger or coin.
N
BATT
METRIC
T
BOTTOM
SURF DEPTH
MAX
. .
Tap Unit at any time to enable the Alternate Screen and Fiber Optic back light.
Surface Interval
(No Nitrogen)
Barometric Altitude
Nitrox O2%
(2500 feet per bar
No bars = 0 to 2500)
(Blend #1 Set Point)
Main
TEMP
Screen
A
S
C
E
N
T
SURF
Alternate
Screen
Surface Interval
Air
CNS Oxygen
(Amount of time
Temperature
Toxicity in %
since the last dive)
Surface Interval
(With Nitrogen)
Dive of "Day"
Time To Fly
(Repetitive Dive
(Hours before
Number)
safely flying.)
Main
FLY
TEMP
Screen
A
D
S
I
C
V
E
E
N
T
BOTTOM
SURF
MAX
DEPTH
Alternate
Screen
Bottom Time
Surface Interval
Max Depth
Fresh batteries are 3.2 volts. Suggest change
(Of the last dive)
(Of the last dive)
(Amount of time
at 2.1 volts. MUST change before 1.6 volts
since the last dive)
Dive Mode
NDC Time Remain
Ascent Rate
Nitrox O2%
Water
(Time you can stay at
(Bar Graph shows
(Current Blend
current depth without
current Ascent Rate)
Temperature
Decompression)
(5 bars = 60 fpm)
Main
REMAIN TIME
TEMP
Screen
A
S
NDC
C
E
N
T
BOTTOM
DEPTH
Alternate
. .
Screen
Depth
CNS Oxygen
Bottom Time
Current PO2
(Depth you are
Toxicity in %
(So far this dive)
(in ATA)
currently at)
Deco Stop Times
Deco Ceiling
Decompression Mode
(Alternates between
(Don't go above this
Total Deco Time & time
Depth for optimum
at the current Stop)
Decompression)
Main
REMAIN TIME
CEIL
Screen
A
S
C
DEC
E
N
T
BOTTOM
DEPTH
DEPTH
Alternate
. .
Screen
1
DISPLAY SCREENS
Cochran EMC-16
One Blend Nitrox
© 2005 Cochran Consulting, Inc.
Unit automatically turns
CEIL
off one hour after a dive
or one hour after being
turned on. Bridging
DEPTH
contacts 1 & 2 will make
unit stay on for another
. .
hour.
. .
Battery
OTU Oxygen
Voltage
Toxicity in %
set point)
MAX
DEPTH
OTU Oxygen
Max Depth
(Of current dive)
Toxicity in %
Deco Dive
(Water Temperature)
TEMP
MAX
DEPTH