FAILURE DIAGNOSIS

(2) P1403/3: Failure B with EGR valve (Step Motor A-phase)

DTC
P1403/3
DTC Detecting Conditions
1 - Precondition; 2 - Detecting condition(s);
3 - Flashing pattern of failure indicator
1. Key switch ON.
2. Make an assessment logically as to followings.E-ECU detects
the EGR step motor A-phase turning OFF during the command
to turn ON the EGR step motor A-phase.
3. One flash followed by three flashes.
Movement at Error occurrence
Error Mode
[Run As Is]:
After detecting the error, the system lets
the engine continue to run without any
restrictions.
Run restricted?
No.
Recovery
No.
Conditions
Remarks
Estimation of Failure cause/Error condition
• The connector may not be properly connected.
• Wiring defect of the harness
The EGR step motor A-phase wiring may be short-circuited with POWER SUPPLY.
The EGR step motor wiring may be short-circuited between phases.
• The EGR step motor may be faulty.
Inner wiring of the EGR step motor A-phase may be short-circuited with POWER SUPPLY.
Inner wiring of the EGR step motor may be short-circuited between phases.
• The E-ECU internal circuitry may be faulty.
1-86
DTCs (Diagnostic Trouble Codes) General Description
Failure B with EGR valve (Step Motor A-Phase)
Movement setting at the EGR step motor error
Unavailable
Check points
Connector
Harness
EGR valve (step motor)
E-ECU
Available
[Run Under Restrictions]:
The engine continues to run under
restrictions.
Yes: The system restricts the High idle
speed or engine power.
No.
TNV DI Service Manual