P0119/2: Intermittent Failure With Cooling Water Temperature Sensor - Yanmar 3TNV82A Troubleshooting Manual

Electronic control
Hide thumbs Also See for 3TNV82A:
Table of Contents

Advertisement

DTCs (Diagnostic Trouble Codes) General Description

(3) P0119/2: Intermittent Failure with Cooling Water Temperature Sensor

DTC
P0119/2
DTC Detecting Conditions
1 - Precondition; 2 - Detecting condition(s);
3 - Flashing pattern of failure indicator
1. Engine running.
2. Unconfirmed error detected 10 times.
3: Does not flash.
Movement at Error occurrence
Error Mode
[Run As Is]:
After detecting the error, the system lets the engine continue to run without any
restrictions.
Run restricted?
No.
Recovery
No.
Conditions
Remarks
Estimation of Failure cause/Error condition
• The connector may not be properly connected.
• Wiring defect of the harness
The cooling water temperature sensor's signal wires may be short-circuited with GND.
The cooling water temperature sensor's signal wires may be disconnected or short-circuited with
POWER SUPPLY.
GND wire of the cooling water temperature sensor may be disconnected.
• The cooling water temperature sensor may be faulty.
Signal wire in the sensor may be disconnected, or short circuited.
Sensor GND wire in the sensor may be disconnected.
TNV DI Service Manual
Intermittent Failure with Cooling Water Temperature
Sensor
Connector
Harness
High-accuracy cooling water
temperature sensor
E-ECU
FAILURE DIAGNOSIS
Check points
1-49