X440-G2 Series Switch Quick Reference
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Risques d'électrocution: Seul un personnel qualifié doit effectuerles
procédures d'installation.
For complete installation instructions see the Extreme Networks
Summit Family Hardware Installation Guide at:
www.extremenetworks.com/documentation
Hardware Components
The following figures display the front and rear panel ports, LEDs,
and hardware components on a typical X440-G2 switch. See the
Extreme Networks Summit Family Hardware Installation Guide for
component details.
Note: Switch models X440-G2-12t8fx-GE4, X440-G2-24fx-GE4, and X440-G2-
24t-GE4 do not support stacking. The front panel stack LED on these models
does not function.
Figure 1
X440-G2 Sample Front Panel
1 USB port
4 10/100/1000BASE-T copper ports
2 Stack LED
5 1000BASE-X SFP ports
3 Console/Management ports
6 Shared ports
Figure 2
X440-G2 Sample Rear Panel (AC power)
1 10GBASE-X SFP+ ports
4 Redundant power input
2 10GBASE-T copper ports
5 Grounding lug
3 AC power input socket
6 Shared ports
Figure 3
X440-G2 Sample Rear Panel (DC power)
1 10GBASE-X SFP+ ports
4 DC power connector panel
2 10GBASE-T copper ports
5 Grounding lug
3 Redundant power input
6 Shared ports
Installation Site Requirements
The installation site must be within reach of the network cabling
and meet the requirements listed below:
• Appropriate grounded power receptacles must be located
within six feet of the site.
• A temperature of between 0°C (32°F) to 60°C (140°F) with
fluctuations of less than 10°C (18°F) per hour must be
maintained for the following X440-G2 switches:
– X440-G2-12t8fx-GE4
– X440-G2-24fx-GE4
– X440-G2-24t-GE4
For all other X440-G2 series switches, a temperature of
between 0°C (32°F) and 50°C (122°F) must be maintained at
the installation site with fluctuations of less than 10°C (18°F) per
hour.
Caution: To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in.) on both sides of the device.
Warning: A readily accessible disconnect device shall be incorporated in the
building installation wiring.
Handling the Switch
Caution: The switch can be damaged by electrostatic discharge.
To prevent electrostatic damage, attach an electrostatic discharge
(ESD) wrist strap to your wrist before handling the switch.
Unpack the switch as follows:
1 Remove the packing material protecting the switch.
2 Remove the tape seal on the non-conductive bag to remove the
switch.
3 Perform a visual inspection of the switch for any signs of
physical damage. Contact Extreme Networks if there are any
signs of damage. See
"Getting Help"
for more information on
contacting Extreme Networks.
Installing the Summit X440-G2 Series Switch
You can install a Summit X440-G2 Series switch in a rack. There are
four possible rack mounting configurations, depending upon
whether:
• The switch I/O ports or the power supply side of the device face
front
• The device is mounted flush with the rack posts or mid-mounted
Secure the X440-G2 Series switches to the Rack
Caution: Before rack-mounting the device, ensure that the rack can support it
without compromising stability. Otherwise, personal injury and/or equipment
damage may result.
Note: The rack mounting brackets provide two holes for securing the Summit
X440-G2 Series switches to the rack. Use two screws or fasteners appropriate
to your rack on each side when securing the X440-G2 Series switch to the rack.
To secure the Summit X440-G2 Series switches to the rack:
1 Attach the mounting brackets to the sides of the switch using
six screws for each bracket.
2 Align the rack mount ear holes with the front rack post holes.
3 Secure the Summit X440-G2 Series switches to each rack post
with two screws or fasteners appropriate to the rack.
Install Optical Transceivers
Warning: LASER RADIATION
Fiber-optic ports use Class 1 or Class 1M lasers.
DO NOT EXPOSE USERS OF TELESCOPIC OPTICS
Do not use optical instruments to view the laser output. The use of optical
instruments to view laser output increases eye hazard. Use only UL/CSA
recognized pluggable modules.
Avertissements: RAYONNEMENT LASER
Ports de fibres optiques utilisent des lasers de classe 1 ou de
classe 1M .
NE PAS exposer les utilisateurs de télescopique OPTIQUE.
Ne pas utiliser d'instruments optiques pour voir la sortie du laser.
L'utilisation de instruments optiques pour afficher la sortie laser
augmente les risques oculaires. Utilisez uniquement UL / CSA
reconnue modules enfichables.
This installation procedure applies to all optical transceivers. To
install a transceiver in a Summit X440-G2 Series switch:
1 Attach the anti-static wrist strap to your wrist and connect the
metal end to an appropriate ground point on the rack.
2 Remove the optical transceiver from the packaging.
3 If there is a protective dust cover on the connector, remove it at
this time.
4 Hold the optical transceiver so that the connector will seat
properly.
5 Carefully align the optical transceiver with the port slot.
6 Push the optical transceiver into the port slot until the
transceiver clicks and locks into place.
Connect Power to the Switch
Warning: Extreme Networks power supplies do not have switches for turning
the unit on and off. Disconnect all power cords to remove power from the
device. Make sure that these connections are easily accessible.
Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each
power supply connection.
Warning: Always make sure that the DC circuit is de-energized before
connecting or disconnecting DC power cables.
You can connect to a single, primary source of power, or to two
sources of power for redundancy.
Note: Installing the system as described in this guide meets the protective earth
grounding requirements of the National Electrical Code (NEC) UL 60950 and
IEC 60950 standards. However, in some cases, it may be necessary to use an
alternative grounding method. In these cases, a 14 AWG wire can be connected
between the ground lug on the chassis and a nearby building ground point.
To power-up your X440-G2 Series switch, do the following:
1 For AC powered units, connect the AC power cord to the AC
power input socket on the switch and an AC power outlet.
2 For DC powered switches, first verify the DC circuit is de-
energized and then do the following:
a Identify the grounding lug on the back of the switch. The
grounding lug is the middle screw of the power connector
panel, identified by the international symbol for earth ground.
b Connect the spade terminal end of the ground wire to the
grounding lug of the power connector panel on the rear of
the switch and the other end to a reliable earth ground.
c Connect the DC power input cables to the DC input terminal
block on the rear of the switch.
d Energize the circuit.
3 If applicable, attach the cable from your redundant power
supply (RPS) into the X440-G2 Series switch's redundant power
supply receptacle.
4 Once power is connected, verify that the PSU LED and RPS LED
(if applicable) turns green. If the PSU and RPS LEDs do not turn
green, refer to the Extreme Networks Summit Family Hardware
Installation Guide for troubleshooting information.
Selection of Power Cords
Extreme Networks does not include any power input cords. To
purchase the correct power cord for your specific country, refer to
www.extremenetworks.com/product/powercords/
for power cord
details to purchase a cord from Extreme Networks or your local
supplier.
Initial Network Connection and Configuration
Once you have connected power to the switch and verified LED
activity, complete the setup process as follows:
1 Connect a management station to the console port using either
an Ethernet to serial adapter or DB-9 serial cable
2 Verify that the system LEDs are on (solid green or blinking
green).
3 Using PuTTY, TeraTerm, or other terminal emulator, connect to
the switch using the serial port connection. Be sure that your
serial connection is set properly:
– 9600 baud
– 8 data bits
– 1 stop bit
4 Using the console session, perform the following:
a At the password prompt, press ENTER (RETURN) twice.
b Enter user: admin
c For the initial password, simply press ENTER.
d Follow the screen prompts for initial configuration.
e Enter the show version command. Record the switch serial
number. The following is example output with the serial
number in bold:
Transit.3 # show version
Switch : 800444-00-05 1208G-00882 Rev 5.0 BootROM:
5 Go to Extreme Networks e-support at
https://
esupport.extremenetworks.com
6 After logging in, go to the product registration page:
http://
extrwebapps.extremenetworks.com/Webapps/Public/
ProductReg/.
7 Enter the serial number of the switch.
8 Download the software to your pc from the software download
page at the esupport website:
https://
esupport.extremenetworks.com/eservice_enu/
start.swe?SWECmd=Login&SWEPL=1&SWETS=
9 Connect back to the switch via the console port and connect a
Ethernet cable to the management port on the switch to your
PC.
10 You might need to reset the IP address on your PC to some
address (for example, 10.10.10.10 255.255.255.0) to avoid
IP conflict.
11 At the switch, set the IP address of the switch (for example,
enter: con mgmt ipa 10.10.10.9/24).
12 Enter save config to save your configuration.
13 Start a TFTP session using a program such as TFTPD64. Point
the TFTP server to your PC IP address and EXOS image file
saved on your PC.
14 At the switch, download the new software to the switch
(example: download image 10.10.10.10 summitX-
15.4.1.3-patch1-9.xos).
15 Install the software after it loads by typing Y when prompted if
you want to install the load.
16 When the download and install finishes, instruct the switch to
reboot when prompted by entering: reboot.
Optional CLI Commands
Once logged into the switch you can create new VLANs by issuing
the following two commands:
create vlan <vlan name>
(replace XXXX
configure vlan <vlan name> tag XXXX
with the VLAN tag number - options are 1-4096)
These two commands will create a VLAN, give it a logical name,
and assign a tag number.
To configure a Default Gateway in the Extreme Networks CLI,
enter: configure iproute add default <IP Address>
Port Configuration CLI Commands
For additional port configuration CLI commands, refer to the
Extreme XOS Command Reference Guide at:
www.extremenetworks.com/documentation.
Specifications
Temperature and Humidity
Operating Temperature:
X440-G2-12t8fx-GE4, X440-G2-24fx-GE4,
and X440-G2-24t-GE4: 0°C (32°F) to 60°C (140°F)
All other X440-G2 switches: 0°C (32°F) to 50°C (122°F)
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
10% to 95% (non-condensing)
Power Specifications
X440-G2-24t-10GE4
100-240Vac, 0.45 A max., 50-60Hz
(Part # 16532)
X440-G2-24p-10GE4
100-240Vac, 4.9 A max., 50/60Hz
(Part # 16533)
X440-G2-48t-10GE4
100-240Vac, 0.7 A max., 50-60Hz
(Part # 16534)
X440-G2-48p-10GE4
100-240Vac, 9.2 A max., 50/60Hz
(Part # 16535)
X440-G2-12t-10GE4
100-240Vac, 0.35 A max., 50-60Hz
(Part # 16530)
X440-G2-12p-10GE4
100-240Vac, 2.6 A max., 50-60Hz
(Part # 16531)
X440-G2-24t-10GE4-DC
-48V DC, 1.0 A
(Part # 16536)
X440-G2-48t-10GE4-DC
-48V DC, 1.45 A
(Part # 16537)
X440-G2-24x-10GE4
100-240Vac, 0.8 A max., 50-60Hz
(Part # 16538)
X440-G2-24fx-GE4
100-240Vac, 0.65 A max., 50-60Hz
(Part # 16539)
X440-G2-12t8fx-GE4
100-240Vac, 0.5 A max., 50-60Hz
(Part # 16540)
X440-G2-24t-GE4
100-240Vac, 0.45 A max., 50-60Hz
(Part # 16541)
Switch Dimensions
X440-G2-24t-10GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.66 kg (8.07 lb)
X440-G2-24p-10GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 4.28 Kg (9.44 lb)
X440-G2-48t-10GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 5.03 Kg (11.09 lb)
X440-G2-48p-10GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 6.54 Kg (14.42 lb)
X440-G2-12t-10GE4
4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.62 Kg (5.78 lb)
X440-G2-12p-10GE4
4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 3.03 Kg (6.68 lb)
X440-G2-24t-10GE4-DC
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.66 kg (8.07 lb)
X440-G2-48t-10GE4-DC
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 5.02 Kg (11.07 lb)
X440-G2-24x-10GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.64 Kg (8.02 lb)
X440-G2-24fx-GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.76 Kg (8.29 lb)
X440-G2-12t8fx-GE4
4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.88 Kg (6.35 lb)
X440-G2-24t-GE4
4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.62 kg (7.98 lb)
Interfaces
Each Summit X440-G2 Series switch has a USB, management, and
console port. The following table lists the specific interfaces for
each switch.
X440-G2-24t-10GE4
Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4
(Part # 16532)
10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port,
ExtremeXOS Edge license
X440-G2-24p-10GE4
Summit X440-G2 24 10/100/1000BASE-T POE+, 4 SFP
(Part # 16533)
combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1
RPS port, ExtremeXOS Edge license.
X440-G2-48t-10GE4
Summit X440-G2 48 10/100/1000BASE-T, 4 SFP combo, 4
(Part # 16534)
10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1
Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-48p-10GE4
Summit X440-G2 48 10/100/1000BASE-T POE+, 4 SFP
(Part # 16535)
combo, 4 10GBASE-X unpopulated SFP+, 2 10GE copper
combo, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge
license
X440-G2-12t-10GE4
Summit X440-G2 12 10/100/1000BASE-T, 4 10GBASE-X
(Part # 16530)
unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS
Edge license
X440-G2-12p-10GE4
Summit X440-G2 12 10/100/1000BASE-T POE+, 4 10GBASE-
(Part # 16531)
X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port,
ExtremeXOS Edge license
X440-G2-24t-10GE4-DC
Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4
(Part # 16536)
10GBASE-X unpopulated SFP+, 1 Fixed DC PSU, 1 RPS port,
ExtremeXOS Edge license
X440-G2-48t-10GE4-DC
Summit X440-G2 48 10/100/1000BASE-T, 4 SFP combo, 4
(Part # 16537)
10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1
Fixed DC PSU, 1 RPS port, ExtremeXOS Edge license.
X440-G2-24x-10GE4
Summit X440-G2 24 unpopulated 1000BASE-X SFP, 4 10/
(Part # 16538)
100/1000 combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed
AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24fx-GE4
Summit X440-G2 24 fixed 100BASE-FX LC connectors, 4
(Part # 16539)
1GBASE-X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port,
ExtremeXOS Edge license
X440-G2-12t8fx-GE4
Summit X440-G2 12 10/100/1000BASE-T, 8 fixed 100BASE-
(Part # 16540)
FX LC connectors, 4 1GBASE-X unpopulated SFP, 1 Fixed AC
PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24t-GE4
Summit X440-G2 24 fixed 10/100/1000BASE-TX, 4 1GBASE-
(Part # 16541)
X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS
Edge license

Advertisement

loading

Summary of Contents for Extreme Networks Summit X440-G2-24t-10GE4

  • Page 1 X440-G2-24p-10GE4 100-240Vac, 4.9 A max., 50/60Hz procédures d'installation. details to purchase a cord from Extreme Networks or your local Installing the Summit X440-G2 Series Switch (Part # 16533) supplier. You can install a Summit X440-G2 Series switch in a rack. There are X440-G2-48t-10GE4 100-240Vac, 0.7 A max., 50-60Hz...
  • Page 2: Series Switches

    Copyright © 2015 Extreme Networks, Inc. All Rights Reserved. X440-G2-24t-10GE4 Legal Notices Warning: The X440-12t8fx-GE4, X440-24fx-GE4, and Extreme Networks, Inc., on behalf of or through its wholly-owned subsidiary, X440-G2-24p-10GE4 X440-24t-GE4 are designed for installation in restricted access Enterasys Networks, Inc., reserves the right to make changes in locations.

This manual is also suitable for:

Summit x440-g2-24p-10ge4Summit x440-g2-48t-10ge4Summit x440-g2-48p-10ge4Summit x440-g2-12t-10ge4Summit x440-g2-12p-10ge4Summit x440-g2-24t-10ge4-dc ... Show all