autologout
autologout
Syntax:
autologout <time>
Description:
To set up the timer of autologout.
Argument:
<time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180
seconds.
Possible value:
<time>: 0,1-3600
Example:
FGS-2824# autologout 3600
Set autologout time to 3600 seconds
bandwidth
disable egress-rate
Syntax:
disable egress-rate <range>
Description:
To cancel the egress-rate of the port.
Argument:
<range>:syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 to 24
Example:
FGS-2824(bandwidth)# disable egress-rate 1-8
disable ingress-rate
Syntax:
disable ingress-rate <range>
Description:
To cancel the Ingress-rate of the port.
Argument:
<range>:syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 to 24
Example:
FGS-2824(bandwidth)# disable ingress-rate 1-8
Publication date: July, 2005