troubleshooting Guide
prOBLEm
Tool does not
fire.
Opening and
closing of bar-
rel or pushing
down on the
tool, etc. is not
smooth but is
rough or binds.

application Chart

power load and power fastener application information.
For fastening
this:
pOSSIBLE
CaUSE
Failure of tool
to depress com-
pletely.
Dirt build-up on
breech not allow-
ing proper pen-
etration of firing
pin.
Safety Switch is in
ON position
Lack of proper
cleaning.
to this:
rEmEDY
See data listed under
Tool does not completely
depress, above.
Check firing pin indenta-
tion on cartridge. Clean
breech, breech face, sear
and firing pin. Replace
worn or damaged parts.
Rotate Safety Switch to
OFF position.
Inspect and clean com-
plete tool. Replace worn
or damaged parts.
power fastener
length
0
power load
color
119586