Download Print this page
GPI 01N31GM Owner's Manual

GPI 01N31GM Owner's Manual

Electronic water meters

Advertisement

Quick Links

Owner's Manual for
01N31GM, 01N31LM and
01N12LM Electronic Water Meters
Batteries included.
IMPORTANT NOTICE
Use this meter for water only. Do not use to meter
fuel or chemicals.
This meter is not legal for trade applications.
The meter is very sensitive to electrical "noise"
and may not operate correctly if located near some
electrical equipment.
CALIBRATION
This meter has a permanent factory calibration for
measuring water. If installed and used correctly, inac
curacies of no great er than ±5% will be obtained.
INSTALLATION
This meter may be installed in-line either horizon
tally or vertically or at the end of the hose adja-cent
to the nozzle, if present. Installation to metal con
nections is not recommended. Install as follows:
1. If necessary, remove nozzle from hose.
2. Apply pipe sealant to all threaded connec
tions.
3. Attach meter to hose with arrow on outlet port
pointed in the direction of flow.
4. If necessary, attach nozzle to meter.
5. Hand tighten the meter at the housing ends. Do
not use a wrench or similar tools to tighten the
meter housing. The plastic housing could be
damaged.
05/09
OPERATION
Batch and Cumulative Totals
The meter maintains two totals. The batch total
may be reset to measure flow during a single use.
The cumulative total provides continuous measure
ment and may not be manually reset. The batch total
is labeled as TTL1. The cumulative total is labeled
TTL2.
When the cumulative total reaches a maximum
reading of 9999, it will automatically reset to zero.
Press the DISPLAY button briefly to switch
between the batch and cumulative total.
Activate the Meter
Turn the meter ON by starting water flow or briefly
pressing the DISPLAY button. The meter will display
the batch or cumulative total from last use.
Press DISPLAY briefly to display the batch total.
Hold the DIS PLAY button down for three seconds
to reset the batch total to zero.
The meter is programmed to turn o automatically
if not used for about one minute.
MAINTENANCE
-
Proper handling and care will extend the life and
service of the meter.
Turbine Rotor
-
The meter is virtually maintenance-free. However,
it is important the rotor moves freely. Keep the meter
-
clean and free of contaminants.
If the rotor does not turn freely, apply a penetrating
lubricant on the rotor, shaft, and bearings. Remove
any debris or deposits from the rotor using a soft
-
brush or small probe. Be careful not to damage the
turbine rotor or supports.
CAUTION : Blowing compressed air through the
turbine assembly could damage the rotor.
5252 East 36th Street North
W ichita, KS USA
67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
Rev. A 920756-01
-