Section 2

Dimensions

Model
Length
36.00"
EHEI36
(91cm)
48.00"
EHEI48
(122cm)
60.00"
EHEI60
(152cm)
74.00"
EHEI74
(188cm)

Capacity

Model
EHEI36
EHEI48
EHEI60
EHEI74
Electrical Service
Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
n
This appliance must be grounded and all field wiring must
conform to all applicable local and national codes. Refer
to rating plate for proper voltage. It is the responsibility of
the end user to provide the disconnect means to satisfy
the authority having jurisdiction.
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for each
unit.
• A qualified electrician must determine proper wire size
dependent upon location, materials used and length of
run (minimum circuit ampacity can be used to help select
the wire size).
• The maximum allowable voltage variation is ±10% of the
rated voltage at equipment start-up (when the electrical
load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
Part Number: 9291472 05/18
Depth
Height
31.50"
36.00"
(80cm)
(91cm)
31.50"
36.00"
(80cm)
(91cm)
31.50"
36.00"
(80cm)
(91cm)
31.50"
36.00"
(80cm)
(91cm)
Number of 11.87" x 19.87"
(30.2cm x 50.5cm) openings
2
3
4
5
DANGER
Warning
Voltage, Cycle,
Model
Phase
EHEI36C
120, 60, 1
EHEI36C-E
240, 50, 1
EHEI36L
120, 60, 1
EHEI36L-E
240, 50, 1
EHEI48C
208/230, 60, 1
EHEI48C-E
240, 50, 1
EHEI48L
208/230, 60, 1
EHEI48L-E
240, 50, 1
EHEI60C
208/230, 60, 1
EHEI60C-E
240, 50, 1
EHEI60L
208/230, 60, 1
EHEI60L-E
240, 50, 1
EHEI74C
208/230, 60, 1
EHEI74C-E
240, 50, 1
EHEI74L
208/230, 60, 1
EHEI74L-E
240, 50, 1

Leg Leveling

All four legs are adjustable. Adjust each leg until the unit
is stable and level, both front to back and left to right. A
level unit is necessary to maintain an equal water depth
throughout the wells.

Plumbing

n
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner's responsibility to provide a container or
outlet for drainage.
A waste connection is provided 26.5" (67cm) above the
floor, 5.25" (13cm) from the right end. You must supply the
required 1/2" (1.3cm) connection at the gate valve.
Installation
Amps
Plug
20.0
Hard wired
-
CEE 7/7
20.0
5-30P
-
CEE 7/7
15.0/16.0
Hard wired
-
CEE 7/7
15.0/16.0
6-20P
-
CEE 7/7
20.0/22.0
Hard wired
-
CEE 7/7
20.0/22.0
6-30P
-
CEE 7/7
24.0/27.0
Hard wired
-
CEE 7/7
24.0/27.0
6-50P
-
CEE 7/7
Warning
Watts
-
2900
-
2900
-
4350
-
4350
-
5800
-
5800
-
7250
-
7250
5