Download Print this page
Mitsubishi Electric GT2510-WXTBD User Manual

Mitsubishi Electric GT2510-WXTBD User Manual

Graphic operation terminal, got2000

Advertisement

Quick Links

GT25 Wide Model
General Description
GT2510-WXTBD
GT2510-WXTSD
GT2507-WTBD
GT2507-WTSD
Thank you for purchasing Mitsubishi Electric Graphic Operation
Terminal.
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL
GT25-W-U-GD-E
Model
1D7MS5
code
IB(NA)-0800564ENG-B(1804)MEE
© 2017MITSUBISHI ELECTRIC CORPORATION
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this
product.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Indicates that incorrect handling may cause
WARNING
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
CAUTION
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Note that the
CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are
important to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
WARNING
 Some failures of the GOT or cables may keep the outputs on or off.
Some failures of a touch panel may cause malfunction of the input objects
such as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
 Do not use the GOT as the warning device that may cause a serious
accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
 The GOT backlight failure disables the operation on the touch switch(s).
When the GOT backlight has a failure, the POWER LED blinks (orange/blue)
and the display section dims. In such a case, the input by the touch switch(s)
is disabled.
 The display section of the GOT is an analog-resistive type touch panel.
When multiple points of the display section are touched simultaneously, an
accident may occur due to incorrect output or malfunction.
Do not touch the display section in 2 points or more simultaneously.
If you touch the display section simultaneously in 2 points or more, the switch
that is located around the center of the touched point, if any, may operate.
Doing so may cause an accident due to incorrect output or malfunction.
 When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT, or turn on the
unit again after shutting off the power as soon as possible.
Not doing so can cause an accident due to false output or malfunction.
 If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
[TRANSPORTATION PRECAUTIONS]
CAUTION
 When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User's Manual (Hardware) for details of the
regulated models.)
 Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of this manual, as they are
precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
 When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden
packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other
than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
Manual
The following shows manuals relevant to this product.
Manual name
Manual number (Model code)
GOT2000 Series User's Manual (Hardware)
SH-081194ENG (1D7MJ5)
GOT2000 Series User's Manual (Utility)
SH-081195ENG (1D7MJ6)
For detailed manuals and relevant manuals, refer to the Help or the PDF
manuals stored in the DVD-ROM for the drawing software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (http://www.MitsubishiElectric.com/fa/).
Compliance with the new China RoHS directive
GOT 相关的基于 " 电器电子产品有害物质限制使用管理办法 " 要求的表示方法
Note: This symbol mark is for China only.
含有有害 6 物质的名称、含有量、含有部件
本产品中所含有的有害 6 物质的名称、含有量、含有部件如下表所示。
产品中有害物质的名称及含量
有害物质
部件名称
六价铬
多溴联苯
多溴二苯醚
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
电路板组件
×
树脂壳体、电缆、膜材
钣金部件、螺丝等金属部件
×
本表格依据 SJ/T11364 的规定编制。
○ : 表示该有害物质在该部件所有均质材料中的含量均在 GB/T26572 规定的限量要
求以下。
× : 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 规定的
限量要求。
Referenced Standard: GB/T15969.2
(Requirement of Chinese standardized law)
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
Refer to the GOT2000 Series User's Manual (Hardware) for the connection
instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User's Manual (Hardware).
1
WARNING
2
3
 To maintain the safety of the system incorporating the GOT, take measures
against unauthorized access from external devices via a network.
4
To maintain the safety against unauthorized access via the Internet, take
5
measures such as installing a firewall.
 Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in
6
Class I, Division 2, Groups A, B, C and D hazardous locations, or
7
nonhazardous locations only.
This mark indicates that the product is certified for use in the Class I,
8
Division2 environment where flammable gases, vapors, or liquids are not
likely to exist under normal conditions.
9
When using the products in the Class I, Division 2 environment, observe the
0
following to reduce the risk of explosion.
• This device is open-type and is to be installed in an enclosure suitable for
the environment and require a tool or key to open.
1
• Warning - Explosion Hazard - Substitution of any component may impair
suitability for Class I, Division 2.
2
• Warning - Explosion Hazard - Do not disconnect equipment unless power
3
has been removed or the area is known to be non-hazardous.
• The wireless LAN communication unit interface of this device cannot be
4
used in Class I, Division 2 environment.
5
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être
utilisés en Class I, Division 2, local dangereux de groupe A, B, C et D, ou
6
uniquement en local non dangereux.
Ce logo indique que le produit est homologué pour utilisation en
7
environnement de Class I, Division 2 où, dans des circonstances anormales,
8
il peut y avoir présence de gaz, vapeurs ou liquides inflammables.
Si le produit est utilisé en environnement de Class I, Division 2, observer les
9
précautions suivantes pour réduire le risque d'explosion.
• Cet appareil est de type ouvert et il doit être installé dans une enceinte
0
appropriée à l'environnement et ne pouvant être ouverte qu'au moyen
d'une clé ou d'un outil.
• Avertissement - Danger d'explosion - Toute substitution de composant
peut compromettre l'aptitude à l'utilisation en Class I, Division 2.
• Avertissement - Danger d'explosion - Ne pas déconnecter l'équipement
quand le circuit est sous tension, ni avant de d'être assuré de l'absence
d'atmosphère inflammable.
• L'interface de l'unité de communication LAN sans fil de cet équipement ne
peut pas être utilisée dans les environnements de Classe I, Division 2.
CAUTION
 Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100 mm apart.
Not doing so noise can cause a malfunction.
 Do not press the GOT display section with a pointed material as a pen or
driver.
Doing so can result in a damage or failure of the display section.
 When the GOT is connected to the Ethernet network, the available IP
address is restricted according to the system configuration.
When a GOT2000 series model and a GOT1000 series model are on an
Ethernet network, do not set the IP address 192.168.0.18 for the GOTs and
the controllers on this network.
Doing so can cause IP address duplication at the GOT startup, adversely
affecting the communication of the device with the IP address 192.168.0.18.
The operation at the IP address duplication depends on the devices and the
system.
 When using the Ethernet interface, set a different network for port 1 and
port 2.
 Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
 When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
[MOUNTING PRECAUTIONS]
WARNING
 Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
 Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the option unit onto/from the GOT.
CAUTION
 Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product
damage or deterioration.
 When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head
screwdriver No.2.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or the GOT.
 When mounting the wireless LAN communication unit on the GOT, fit it to the
wireless LAN communication unit interface and tighten the mounting screws
in the specified torque range (0.10 N•m to 0.14 N•m) with a Phillips-head
screwdriver No.1.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
 When closing the USB environmental protection cover, fix the cover to the
GOT by pushing the [PULL] mark on the latch firmly to comply with the
protective structure.
 Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may
not be removed.
 Operate and store the GOT in environments without direct sunlight, high
temperature, dust, humidity, and vibrations.
Packing List
The GOT product package includes the following:
Description
GT25 Wide Model
Battery (GT11-50BAT) (Attached to the GOT)
Installation fitting
GT25 Wide Model General Description (This manual)
GT25 ワイドモデル本体概要説明書
1. FEATURES
(1) Abundant standard equipment
• Variety of connection with FA devices
• SD card interface compatible with the SDHC card having a large capacity
and allowing high-speed communication
• Connection with various peripheral devices with the USB host
• One sound output interface
• Two Ethernet interfaces
(2) Improved usability
• Abundant troubleshooting
• Easy and clear screen creation
• PC-like operation screen
• Support for the vertical installation
(3) Enhanced compatibility with Mitsubishi FA devices
(4) LED backlight
2. Part Names and Settings
The following shows the part names for GT2510 and GT2507.
5)
GT2510
1)2)
16)
24)
3)
4)
5)
22)
21)
18)19) 17)
(PBDE)
20)
GT2507
1)2)
16)
24)
3)
4)
22)
21)
18)19)
17)
20)
No.
Name
1)
Display screen
Displays the utility and the user-created screen.
For operating the touch switches in the utility and the user-
2)
Touch panel
created screen
USB interface (Device
For connecting a personal computer (connector type: Mini-
3)
/Front face)
B)
Lit in blue
Lit in orange
4)
POWER LED
Blinks in orange/blue
Not lit
5)
Unit installation fitting
Mounting fixtures for fixing the GOT to the control panel
6)
Reset switch
Hardware reset switch
7)
Installation switch
Used for OS installations at the GOT startup
Lit: SD card mounted
Blinking: SC card accessed
8)
SD card access LED
No lit: SD card not mounted or SD card mounted
(removable)
9)
SD card interface
For installing a SD card
With a switching function for accepting and stopping the
access to the SD card
10)
SD card cover
When the cover is opened : Access is prohibited
When the cover is closed : Access is allowed
[WIRING PRECAUTIONS]
 Be sure to shut off all phases of the external power supply used by the
system before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
 Make sure to ground the FG terminal of the GOT power supply section solely
for the GOT (ground resistance: 100 Ω or less, ground cable diameter: 1.6
mm or more).
Not doing so may result in an electric shock or malfunction.
 When tightening the terminal screws, use a Phillips-head screwdriver No.2.
 Terminal screws which are not to be used must be tightened always at torque
0.5 N•m to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless
terminals.
 Use applicable solderless terminals and tighten them with the specified
torque. If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
 Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure
 Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 N•m to 0.8 N•m). Undertightening can cause a short circuit
or malfunction. Overtightening can cause a short circuit or malfunction due to
the damage of the screws or the GOT.
 Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
 The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring. Before starting system operation, be sure
to peel this label because of heat dissipation.
 Plug the communication cable into the GOT interface or the connector of the
connected unit, and tighten the mounting screws and the terminal screws in
the specified torque range. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to
the damage of the screws or unit.
[TEST OPERATION PRECAUTIONS]
 Before performing the test operations of the user creation monitor screen
(such as turning ON or OFF bit device, changing the word device current
value, changing the settings or current values of the timer or counter, and
changing the buffer memory current value), read through the manual
carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system.
False output or malfunction can cause an accident.
[STARTUP/MAINTENANCE PRECAUTIONS]
 When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
 Correctly connect the battery connector.Do not charge, disassemble, heat,
short-circuit, solder, or throw the battery into the fire.Doing so will cause the
battery to produce heat, explode, or ignite, resulting in injury and fire.
 Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can
cause a unit failure or malfunction. Undertightening can cause a short circuit
or malfunction. Overtightening can cause a short circuit or malfunction due to
the damage of the screws or unit.
 Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
 Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
 The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
 When unplugging the cable connected to the unit, do not hold and pull from
the cable portion. Doing so can cause the unit or cable to be damaged or can
cause a malfunction due to a cable connection fault.
 Do not drop the module or subject it to strong shock. A module damage may
result.
 Doing so may damage the battery, causing the battery fluid to leak inside the
battery. If the battery is dropped or given an impact, dispose of it without
using.
 Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
 Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or explosion.
 Dispose of used battery promptly.
Keep away from children.Do not disassemble and do not dispose of in fire.
 Be sure to shut off all phases of the external power supply before replacing
the battery or using the dip switch of the terminating resistor. Not doing so
can cause the unit to fail or malfunction by static electricity.
No.
Name
11)
Battery holder
Terminating resistor
12)
setting switch
Quantity
(Inside cover)
1
Wireless LAN
13)
communication unit
1
interface
4
USB interface
1
14)
(Host/Back face)
1
Hole for attaching a
15)
cable clamp
Vertical installation
16)
arrow mark
17)
Power terminal
Ethernet interface
18)
(port 1)
Ethernet interface
19)
(port 2)
Ethernet
20)
communication status
LED
21)
RS-422/485 interface
22)
RS-232 interface
23)
Sound output interface
24)
Rating plate
3. Specifications
5)
13)
7)
6)
3.1 General Specifications
9)
Item
10)
Operating ambient
8)
temperature
*1
Température
14)
ambiante de
fonctionnement
*1
15)
Storage ambient
temperature
Operating ambient
humidity
11)12)
23)
5)
Storage ambient
humidity
Compliant
5)
5)
with JIS B
13)
7)
6)
Vibration resistance
3502 and
IEC
61131-2
9)
10)
8)
Shock resistance
14)
Operating
atmosphere
conductive dust, and direct sunlight (Same as storage atmosphere)
15)
*2
Operating altitude
Installation location
5)
11)12)
23)
5)
Overvoltage
*3
category
*4
Pollution degree
Cooling method
Grounding with a ground resistance of 100 Ω or less by using a ground
Grounding
Description
*1: The operating ambient temperature includes the temperature inside the
enclosure of the control panel to which the GOT is installed.
La température ambiante de fonctionnement inclut la température à l'intérieur
du boîtier du tableau de commande sur lequel le GOT est installé.
*2: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0 m (0ft.).
: Power is properly supplied.
: Screen saving
Failure to observe this instruction may cause a malfunction.
: Backlight failure
When an air purge is made inside the control panel by adding pressure, there
: Power is not supplied
may be a clearance between the surface sheet and the screen making it difficult
to use the touch panel, or the sheet may come off.
*3: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*4: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
WARNING
CAUTION
WARNING
WARNING
CAUTION
Description
Houses the battery
For switching on and off of the terminating resistor for the
RS-422/485 communication port (Default (Off))
For installing a communication unit
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data
(connector type: TYPE-A)
For attaching a cable clamp to prevent the USB cable or the
sound output cable from being accidentally pulled out
(Recommended product: RSG-130-V0 made by
KITAGAWA INDUSTRIES CO.,LTD)
For the vertical installation, install the GOT so that the arrow
points upward.
Power input terminal, FG terminal
For communicating with a controller or connecting a
personal computer (connector type: RJ-45 (modular jack))
SD/RD LED ON : Data sent or received
SD/RD LED OFF: Data not sent or received
SPEED LED ON : Communicating at 100 Mbps
SPEED LED OFF: Communicating at 10 Mbps or
disconnected
For communicating with a controller (Connector type: D sub
9-pin (female))
For communicating with a controller (Connector type: D sub
9-pin (male))
For outputting sounds (applicable plug: Φ3.5 stereo mini-
plug (3-prong))
-
Specifications
0 to 55
0 à 55
-20 to 60
10 to 90% RH, non-condensing
10 to 90% RH, non-condensing
Half-
Sweep
Frequency
Acceleration
amplitude
count
5 to
10 times
-
3.5 mm
Under
8.4 Hz
each in X,
intermittent
Y and Z
8.4 to
vibration
2
-
9.8 m/s
150 Hz
directions
5 to
-
1.75 mm
Under
8.4 Hz
-
continuous
8.4 to
2
-
vibration
4.9 m/s
150 Hz
2
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
(15G),
3 times each in X, Y and Z directions
No greasy fumes, corrosive gas, flammable gas, excessive
2000 m (6562 ft) max.
Inside control panel
II or less
2 or less
Self-cooling
2
cable that has a cross-sectional area of 2 mm
or more.
If impossible, connect the ground cable to the control panel.
[TOUCH PANEL PRECAUTIONS]
CAUTION
 For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position
may occur as the period of use elapses.
When any difference between a touched position and the object position
occurs, execute the touch panel calibration.
 When any difference between a touched position and the object position
occurs, other object may be activated.
This may cause an unexpected operation due to incorrect output or
malfunction.
[PRECAUTIONS WHEN THE DATA STORAGE IS IN
USE]
WARNING
 If the SD card is removed from drive A of the GOT while being accessed by
the GOT, the GOT may stop processing data for about 20 seconds.The GOT
cannot be operated during this period. The functions that run in the
background including a screen updating, alarm, logging, scripts, and others
are also interrupted. Since this interruption makes an impact to the system
operation, it might cause failure.After checking the light off of SD card access
LED, remove the SD card.
CAUTION
 If the data storage is removed from the GOT while being accessed by the
GOT, the data storage and files may be damaged. Before removing the data
storage from the GOT, check the SD card access LED, system signal, or
others to make sure that the data storage is not accessed.
 Turning off the GOT while it accesses the SD card results in damage to the
SD card and files.
 When inserting a SD card into the GOT, make sure to close the SD card
cover. Failure to do so causes the data not to be read or written.
 When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out.Failure to do so may cause the SD card to drop
from the GOT, resulting in a failure or break.
 When inserting a USB device into a USB interface of the GOT, make sure to
insert the device into the interface firmly.Failure to do so may cause the USB
device to drop from the GOT, resulting in a failure or break
 Before removing the USB device from the GOT, follow the procedure for
removal on the utility screen of the GOT. After the successful completion
dialog is displayed, remove the USB device by hand carefully. Failure to do
so may cause the USB device to drop from the GOT, resulting in a failure or
break.
[PRECAUTIONS FOR USE]
CAUTION
 Do not touch the edges of the touch panel (display section) repeatedly.
Doing so may result in a failure.
 Do not turn off the GOT while data is being written to the storage memory
(ROM) or SD card.
Doing so may corrupt the data, rendering the GOT inoperative.
[PRECAUTIONS FOR REMOTE CONTROL]
WARNING
 Remote control is available through a network by using GOT functions,
including theSoftGOT-GOT link function, the remote personal computer
operation function, the VNC server function, and the GOT Mobile function.
If these functions are used to perform remote control of control equipment,
the field operator may not notice the remote control, possibly leading to an
accident.
In addition, a communication delay or interruption may occur depending on
the network environment, and remote control of control equipment cannot be
performed normally in some cases.
Before using the above functions to perform remote control, fully grasp the
circumstances of the field site and ensure safety.
[PRECAUTIONS FOR EXCLUSIVE AUTHORIZATION CONTROL]
WARNING
 Make sure to fully understand the GOT network interaction function before
using this function to control the authorization among pieces of equipment to
prevent simultaneous operations.
The exclusive authorization control of the GOT network interaction function
can be enabled or disabled for each screen. (For all screens, the exclusive
authorization control is disabled by default.)
Properly determine the screens for which the exclusive authorization control
is required, and set the control by screen.
A screen for which the exclusive authorization control is disabled can be
operated simultaneously from pieces of equipment. Make sure to determine
the operation period for each operator, fully grasp the circumstances of the
field site, and ensure safety to perform operations.
[DISPOSAL PRECAUTIONS]
CAUTION
 When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to
the local regulations.
(Refer to the GOT2000 Series User's Manual (Hardware) for details of the
battery directive in the EU member states.)
Point
Refer to the GOT2000 Series User's Manual (Hardware) for details on the performance
specifications of each GOT.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT25 wide model
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
Specifications
Item
GT2510-WXTSD,
GT2507-WTSD,
GT2510-WXTBD
GT2507-WTBD
Power supply voltage
DC24V (+25%, -20%)
maximum load
16 W or less
16 W or less
Power
Stand alone
9 W
9 W
consum
Stand alone with
ption
5 W
5 W
backlight off
59 A or less (2 ms, operating ambient temperature 25,
Inrush current
maximum load)
Allowable momentary power
5 ms or less
failure time
500 Vp-p noise voltage, 1 s noise width (when
Noise immunity
measuring with a noise simulator under 25 to 60 Hz
noise frequency)
Dielectric withstand voltage
350 VAC for 1 minute across power terminals and earth
10 M or more across power terminals and earth by a 500
Insulation resistance
V DC insulation resistance tester
2
2
Applicable wire size
0.75[mm
] to 2[mm
]
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
Applicable solderless terminal
V2-N3A, FV2-N3A
Applicable tightening torque
0.5[N•m] to 0.8[N•m]
(Terminal block terminal screw)
3.3 External Dimensions
GT2510
GT2507
252(9.92)
189(7.44)
203(7.99)
145(5.71)
142(5.59)
203(7.99)
24.5
(0.96)
243(9.57)
180(7.09)
Unit : mm (inch)
.

Advertisement

loading

Summary of Contents for Mitsubishi Electric GT2510-WXTBD

  • Page 1 (3-prong)) 2. Part Names and Settings Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, Rating plate Applicable solderless terminal The latest manuals are also available from MITSUBISHI ELECTRIC FA Global V2-N3A, FV2-N3A Website (http://www.MitsubishiElectric.com/fa/). Applicable tightening torque 0.5[N•m] to 0.8[N•m] 3.
  • Page 2 5. INSTALLATION d'installation du tableau de commande Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine Lors de l'installation du GOT sur un panneau, réglez la zone d'affichage 5.1 Dimensions intérieures du tableau de...

This manual is also suitable for:

Gt2507-wtbdGt2507-wtsdGt2510-wxtsd