SYSTEM JUNCTION BOX DIAGNOSTIC LIGHTS

Supply Fault:
There are two conditions that cause this diagnostic light to come on:
1. When this light remains on (but not flashing) it indicates the
machine was turned off by pushing on the red emergency shut off
button on the control panel. The machine will not function while the
light is on. To reset, pull out the button, turn the key switch off, then
on again. This condition does not require service. (The key switch is
the correct way to turn off the machine when it is stored or set aside
for periods of time.)
2. When this light is flashing, it indicates that there is a problem in
either the beacon post or the control panel. In a fault condition the
"supply fault" light starts flashing as soon as the machine is turned on
with the key switch. The machine will not function while the light is
flashing. The control panel lights may remain lighted for 3-seconds
then shut down but the fault light will remain flashing as long as the
fault condition exists.
To determine if the problem is in the beacon post, turn off the machine
with the key switch, unplug the cable leading to the beacon post then
turn the key switch on again. If the problem is in the beacon post the
machine will operate normally but only in the "manual" mode. If the
problem is somewhere in the control panel circuitry, the fault light will
continue to flash and the panel lights will go off in about 3 seconds.
Remote Brake: LED lights to indicate presence of "Brake" command from receiver. It
has no effect in manual mode.
Remote Slow:
LED lights to indicate presence of "Slow" drive command from
receiver.
"Remote" mode in order to operate machine. It has no effect in
manual mode.
Remote Fast:
LED lights to indicate presence of "Fast" drive command from
receiver.
"Remote" mode in order to operate machine. It has no effect in
manual mode.
Drive Command: LED lights to indicate drive signal is being sent to motor control.
Low Battery:
LED lights when battery voltage is too low to operate machine
properly (below approximately 27 volts).
Hour Meter:
Hour glass symbol blinks every ten seconds when drive command is
present to indicate that meter is timing machine operation.
Dane Technologies, Inc.
7105 Northland Terrace, Minneapolis, MN 55428 / 888-544-7779 / 763-544-7779 / Fax 763-544-4234
www.danetechnologies.com
Must light in conjunction with "Drive" Command LED in
Must light in conjunction with "Drive" command LED in
QuicKART 2000
Owner's Manual
970-026 rev 3-1-06
21

Advertisement

Table of Contents
loading

Table of Contents