Connecting to the Gas Valve
The wiring harness for the Proflame GTM system has two wires labeled "TH" & "TPTH". Connect
the wires to the gas valve as labeled. (TH to TH and TPTH to TPTH). Additionally there is a
connector labeled "Motor". Connect this "Motor" connector to the stepper motor on the gas
valve. (Fig. 5)
REMOTE
Fig. 5: Wiring diagram.

OPERATING PROCEDURE

Initializing the System for the first time
Install the 4 AA batteries into the receiver battery bay. Note the polarity of battery and insert into
the battery bay as indicated on the Battery cover (+/-). Place the 3 position slider switch in the
"Remote" position.
Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole
marked "PRG" on the Receiver front cover. The Receiver will "beep" three (3) times to indicate
that it is ready to synchronize with a Transmitter. Install the 3 AAA type batteries in the
Transmitter battery bay, located on the base of the Transmitter. With the batteries already
installed in the Transmitter, push the On button. The Receiver will "beep" four times to indicate
6
the Transmitter's command is accepted and sets to the particular code of that Transmitter. The
system is now initialized.