Temperature indication Display
With the system in the "OFF" position, press the Thermostat Key and the Mode Key at the same
time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of
the Room Temperature display. (Fig. 6)
Fig. 6: Remote Control display in Farenheit and Celsius.
Turn on the Appliance
Press the ON/OFF Key on the Transmitter. The Transmitter display will show all active Icons on the
screen. At the same time the Receiver connects the thermopile to the gas valve millivolt coil and
the appliance main burner turns on. A single "beep" from the Receiver will confirm reception of
the command.
Turn off the Aplliance
Press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only show the room
temperature and Icon (Fig.7). At the same time the Receiver disconnects the thermopile from the
gas valve millivolt coil and the appliance burner turns off. A single "beep" from the Receiver
confirms reception of the command.
Fig. 7: Remote Control display.