Download Print this page
Hide thumbs Also See for GR-D200US:

Advertisement

SERVICE MANUAL
8
2003
YF001
For disassembling and assembling of MECHANISM ASSEMBLY, refer to the SERVICE MANUAL No.86700 (MECHANISM ASSEMBLY).
1
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . .
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
5
TROUBLE SHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17
COPYRIGHT © 2003 VICTOR COMPANY OF JAPAN, LIMITED
DIGITAL VIDEO CAMERA
GR-D200US
GR-D200US [M3D2S9]
TABLE OF CONTENTS
This service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.
No.YF001
2003/8

Advertisement

loading

Summary of Contents for JVC GR-D200US

  • Page 1 YF001 2003 GR-D200US GR-D200US [M3D2S9] For disassembling and assembling of MECHANISM ASSEMBLY, refer to the SERVICE MANUAL No.86700 (MECHANISM ASSEMBLY). TABLE OF CONTENTS PRECAUTIONS ............... 1-3 SPECIFIC SERVICE INSTRUCTIONS .
  • Page 2 SPECIFICATION 1-2 (No.YF001)
  • Page 3: Precautions

    SECTION 1 PRECAUTIONS SAFTY PRECAUTIONS Prior to shipment from the factory, JVC products are strictly emission. Consequently, when servicing these products, inspected to conform with the recognized product safety and replace the cathode ray tubes and other parts with only the electrical codes of the countries in which they are to be specified parts.
  • Page 4 1.1.2 Safety Check after Servicing Examine the area surrounding the repaired location for damage (4) Leakage current test or deterioration. Observe that screws, parts and wires have been Confirm specified or lower leakage current between earth returned to original positions, Afterwards, perform the following ground/power cord plug prongs and externally exposed tests and confirm the specified values in order to verify accessible parts (RF terminals, antenna terminals, video...
  • Page 5: Disassembly

    SECTION 3 DISASSEMBLY BEFORE ASSEMBLY AND DISASSEMBLY • 3.1.1 Precautions Torque driver • Be sure to disconnect the power supply unit prior to mounting Be sure to use to fastening the mechanism and exterior parts and soldering of parts. because those parts must strictly be controlled for tightening •...
  • Page 6 3.2.2 ASSEMBLY/DISASSEMBLY OF CABINET PARTS AND ELECTRICAL PARTS Disassembly procedure NOTE7b: STEP Fig. PART POINT NOTE Be careful of electric shock due to a capacitor for lighting a strobe. RING (VF) Fig.C1-1 S1a,S1b,2(L1) NOTE7c: UPPER ASSEMBLY S2a,COVER(JACK) When attaching the FRONT ASSEMBLY, put the FRONT 2(S2a),S2b,4(S2c),CN2a,b ASSEMBLY securely in the slot of the LOWER CASE.
  • Page 7 (S1a) (S2a) (S1b) COVER (JACK) CN2b CN2a (S2a) (S2c) (S2c) (S2c) (S2c) (S2b) (S2c) (S2a) (S2b) (S2c) (S2c) (S2c) Fig.C1-1 LUG WIRE <CONNECTOR LOCATION> NOTE6c NOTE3 SPACER NOTE3 (S6b) (S4a) (S6b) NOTE4b COVER (JACK) <WIRE CONNECTION> (S4b) NOTE4a LUG WIRE (S4b) 14 SCREW(NO.20) LUG WIRE...
  • Page 8 <MAIN BOARD ASSEMBLY (CONECTOR LOCATION)> NOTE7b,c CN7a CN7b CN7c NOTE7a,8 (S7) CASSETTE COVER (S7) CN7a CN7b CN7c (S8b) (S8b) (S7) (S8a) (S8b) (S8a) (S8b) Fig.C2 CN9a CN9b <MAIN BOARD ASSEMBLY (CONECTOR LOCATION)> CN9c CN9d CN9a (S9a) CN9b CN9f CN9c CN9d (S9b) CN9e CN9f...
  • Page 9 L11a NOTE10c NOTE10a [10] (S10b) NOTE11 [11] (S10b) NOTE10b (S10a) (S11a) (S11b) L11b Fig.C4 NOTE12 (S13) [13] (S12) (S12) (S13) (S13) [12] Fig.C5 (No.YF001)1-9...
  • Page 10 [14] [16] [15] (S14) (S15c) SHIELD COVER (S14) (S15c) (S15c) <PRE/MDA BOARD ASSEMBLY (S15b) (CONNECTOR LOCATION)> (S15a) CN15b CN15c CN15d (S15a) (S15b) CN15f BRACKET(MECHA)ASSEMBLY CN15e (S15a) CN15a · · 0.069N m (0.7kgf Fig.C6 1-10 (No.YF001)
  • Page 11 3.2.3 DISASSEMBLY/ASSEMBLY OF [6] MONITOR ASSEMBLY CAUTION Disassembly procedure of HINGE ASSEMBLY/FPC AS- (1) Be careful in handling the LCD module, especially not to SEMBLY damage or soil the monitor screen.If it is soiled with fin- (1) While removing the two screws (6 and 7) and disengag- gerprints, etc., gently clean it with chamois or the clean- ing the two hooks (L6e, f) in alphabetical order, remove ing cloth.
  • Page 12 3.2.4 ASSEMBLY/DISASSEMBLY OF [10] OP BLOCK ASSMBLY/CCD BOARD ASSEMBLY CAUTIONS ASSEMBLY. Instead, replace the entire CCD BASE (1) During the procedure, remove the OP BLOCK ASSEMBLY. ASSEMBLY if necessary. When removing the OP BLOCK ASSEMBLY, be careful not to damage the lens. Assembly procedure of OP BLOCK ASSEMBLY/CCD (2) During the procedure, be careful in handling CCD BOARD ASSEMBLY...
  • Page 13 3.2.5 DISASSEMBLY/ASSEMBLY OF [11] VF ASSEMBLY • When replacing the VF FPC ASSEMBLY, first remove the VF FPC ASSEMBLY from the VF BOARD ASSEMBLY, exterior parts of the VF ASSEMBLY (UPPER CASE (VF), and remove the FPC from the HOLDER (VF) BOTTOM CASE (VF)).
  • Page 14: Adjustment

    SECTION 4 ADJUSTMENT PREPARATION 4.1.3 TOOLS REQUIRED FOR ADJUSTMENT 4.1.1 Precaution Torque Driver Tweezers YTU94088 YTU94088-003 P-895 Camera system and deck system of this model are specially adjusted by using PC. However, if parts such as the following are replaced, an adjustment is required.
  • Page 15 • Guide driver (Hexagonal) JIG CONNECTOR CABLE CONNECTION To be used to turn the guide roller to adjustment of the linarity Connection procedure of playback envelope. • INF adjustment lens To be used for adjustment of the camera system. For the usage of the INF adjustment lens, refer to the Service Bulletin No.
  • Page 16 Jig connector diagrams MECHANISM COMPATIBILITY ADJUSTMENT 4.3.1 Tape pattern adjustment JIG CONNECTOR CABLE (YTU93106C) NOTE: Prior to the adjustment, remove the cover (ADJUST). MAIN (1) Play back the compatibility adjustment tape. CN108 (2) While triggering the HID1, observe the waveform of NOTE: VPPD ENV_OUT.
  • Page 17: Trouble Shooting

    SECTION 5 TROUBLE SHOOTING SERVICE NOTE (No.YF001)1-17...
  • Page 18 TAKE OUT CASSETTE TAPE (1) Remove the Power Unit (battery or DC code) from the set. (DC3V) (2) Remove one screw, and remove a plate (ADJ). NOTE: CASSETTE COVER For more efficient operation, loosen and move the grip belt prior to the procedure (2). (3) Open the CASSETTE COVER till it is completely opened and fixed.
  • Page 19 EMERGENCY DISPLAY Example (in case of the error number E01): Whenever some abnormal signal is input to the syscon CPU, an error number (E01, as an example) is displayed on the LCD monitor or (in the electronic view finder).In every error status, UNIT IN REMOVE AND such the message as shown below alter nately appear over and...
  • Page 20 JVC SERVICE & ENGINEERING COMPANY OF AMERICA DIVISION OF JVC AMERICAS CORP. www.jvcservice.com(US Only) JVC CANADA INC. Head office : 21 Finchdene Square Scarborough, Ontario M1X 1A7 (416)293-1311 (No.YF001) Printed in Japan...