  • Page 1 MAKING MODERN LIVING POSSIBLE Danfoss Link™ BR Boiler Relay Installation Guide Danfoss Heating Solutions...
  • Page 2: Table Of Contents

    . This is either built into the boiler or it must be installed in the system . Demount other heating control timers in the installation or they will interfere with the Danfoss Link heating control algorithm . If weather compensation is present it should be set to constant comfort .
  • Page 3: Introduction

    Installation Guide Danfoss Link™ BR Introduction The Danfoss Link™ BR (Boiler Relay) is a device for turning gas and oil boilers ON/OFF depending on heating demand . The Danfoss Link™ BR is powered by 230 V~ . Installation The Danfoss Link™ wireless system’s transmission range is suffi- cient for most applications;...
  • Page 4: Wiring

    For further information, see the Danfoss Link™ CC instruction manual . Note: If adding the Danfoss Link™ BR to the Danfoss Link™ CC is unsuccessful, make sure the right Danfoss Link™ CC software version is applied. Correct version: 2.3.27 or higher.
  • Page 5: Configure Danfoss Link™ Br

    Installation Guide Danfoss Link™ BR Configure Danfoss Link Select “Manage Devices” in Select “Configure Device” . “Rooms and Devices” . Select Device to configure Press “Configure Heating” to bring up the heating configu- ration, which will show the current heating preferences and allow them to be edited by pressing the buttons .
  • Page 6: Configure The Br Control Type

    The TPI control will lower the supply line temperature to the necessary level needed at all time. TPI is implemented in Danfoss Link CC software version 2.4.x or higher. VIFZM202 ©...
  • Page 7: Configure The Br Control Reference Room

    Installation Guide Danfoss Link™ BR Always On: The boiler is kept ON regardless of heat demands . Configure the BR Control Reference Room From the “Configure Heating” screen it is possible to select the control reference (i .e . the boiler will be turned ON if any of the selected rooms call for heat) .
  • Page 8: Perform Network Test

    Perform network test Once the Danfoss Link™ BR and all other devices in the system have been registered and the Danfoss Link™ CC is placed in its final position, perform a network test (see separate Danfoss Link™ CC manual) .
  • Page 9: Technical Specifications

    Installation Guide Danfoss Link™ BR Technical specifications Operation voltage 230 V AC, 50 Hz Standby consumption 1 .6 W 3 amps resistive Load 1 amp inductive Rated impulse voltage 2 .5 kV Switching Type 1B Regulation ON/OFF Ambient temperature 0˚ to +45˚C Transmission frequency Wireless Z-wave 868 .42 MHz...